Loading...
HomeMy Public PortalAbout07-0154 Silver Shores LLC i a $t CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 04-6-2007 PERMIT#: 070154 WORK DESCRIPTION: FIRE ALARM WORK LOCATION: 18 SILVER AVE 1-12 OWNER NAME SILVER SHORES LLC ADDRESS 3921 CLEMSON BLVD CITY,ST,ZIP ANDERSON SC 29621 PHONE NUMBER CONTRACTOR NAME SAVANNAH SYSTEMS ADDRESS 5960 OGEECHEED RD UNIT N CITY STATE ZIP SAVANNAH GA 31419 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEE'S CHARGED $ 25.00 PROPERTY IDENTIFICATION# PROJECT VALUATION $ 1.00 TOTAL BALANCE DUE: $ 25.00 It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire, soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: P.0.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328 (912)786-4573-FAX(912)786-5737 www.cityoftybee.org , - 7 •---, • "f!vr..../ IiltiSpertion Report City ot Tybee Island 403 Butler Avenue P.O. Box 2749 Tybee Island, GA 3132 Pm : (912) 7B6-4573 extencion 114 Vex.: (912) 786-9539 Ci 1 .54 Permit 0-7 Date Lti"!•Ziteit -) .D• ; , c, Date Needed Gen. c'ontractor Subcontractor SA-C:0-S Co ntorit N tun hr:-”' J k rg ',4 LI 9 4,-- i_ocation e-5 (LT- AQ ( \•- Date of Incpf_ction (5-7 , - (Th e- Type of Inspection) Pas.G: \, y\ \ ( 6"1.1W4tSr 11) ••• io 1 t 1 MPH-2,5-2W07 08:28 CITY OF TYBEE ISL. �i 912 786 9539 P.01/01 �ztoee O?- v i S-! `y .y CITY OF TYBEE ISLAND — ' ELECTRICAL PERMIT &TEMPORARY SERVICE AFFIDAVIT 0. 0 ,g O -99 Property address: ,IJ E R Pt . (,/Z. Date: 0 3-Z3-O'7 Owner's name: 503 bel 0 Contractor's name: A N .A1 Si S`i_E i•Owner's address: Contractor's address 22i q J3 CZcu,LAN b 44 Owner's telephone: Contractor's telephone: °t l 2_ ,`3-03 p Type of Consfnrction: New )C, Renovation ____'__- Date Inspection Needed: ��� Fi R ALA irr t N S i iu. PLEASE CHECK ALL THAT APPLY: Application for electrical permit: ] Application for temporary service: APPLCATION FOR PERMIT A/C Window Intercom System - _ - _,_ _ _ Range Split Pool Ground Air Compressor _ Loudspeaker System Ranges Telephones Attic Ventilation Fan Meter Box Outlets-110: . Services: Bell Transmitter Microwave Oven 15 or few •( 60 amps or less Border/Outline Lighting Motor(s): 16-25 61-100 amps Building Saw 0-1 hp 26 to40 101-200 amps Central Vacuum 3-8 hp 71 to 100 . 401- Dishwasher 8-15 hp _ 101 or more Temporary Service Disposal 15-25 hp _ Receiver Disc Thermostat • Dryer 25-50 hp Rectifiers 1V Jacks Exhaust Fan 50-100 hp Sign Circuit Water Head Exit Lights over 100 hp Smoke Detector Washing Machine Food Processor Parking Lot Lights _ Spas&Tubs _ Wel Pump Garage Door Opener Pool Lights Special outlet Welders Heater Post Light :Strip Heat X-ray. ice Maker Range Hood Saimrrung Pool _ APPLICATION FOR TEMPORARY SERVICE REQUEST In requesting temporary electrical service,the undersigned understand and agree: 1. Connection of temporary electrical service provides does not remove the requirement to comply with all State of Georgia minimum construction codes. 2. Temporary electrical pow is intended for completion of the construction process and testing equipment installed within the structure. a Issuing approval for temporary pow connection does not constitute approval to occupy the structure. A Certificate of Occupancy must be issued by the City of Tybee Island prior to any occupancy. 4. The owner and contractor we hereby held responsible for any violations of this policy. A violation of this policy may result in disconnection of the electrical service until all violations and deficiencies are corrected. Ownner's signature: Date: _Contractor's :'! alum: ��_ ,�_., _ Date: v3 2 a7 Code t c• . r ' Day: ,/Wo—__ r Community Development Directs: Date: Fee: Initials: umormsSptrmd-brae remoral_doc .!ornery 28 2m12 TOTAL P.01 Savannah Systems a Division of Jacksonville Sound&Communications,Inc. 2219-B Rowland Ave Savannah, GA 31404 912-303-0310 - phone 912-303-0390 - fax LETTER OF TRANSMITTAL DATE: 03/23/07 JOB NO: S06-053 .......:.:...:..... C.::�.�::�::..:�.::�::.�::.:�::.�:::::}:�::�:�:isi�::�:.:<�i::::ii:::�::�::�::..:-:::�::is i::::�::•i:::::ii::::�::�::::5:.::•..:.........:...:.:.:.:...:..:::.::::... ...... ...... ... .........................................................................:v.:.....:.::::::.:�:::::.::.:�::::::.�::::::.�:.�::.._:::iii:.i:.i:v::.::.::.:::.iii::.::.:ii: 1 2 Copies Submittals 2 1 Copy Application for permit 3 2 Copies Fire Alarm Drawings N.00101111016i''' ''''"' '''' ' ' '' ' !' ' 2 '' ''''''''2 2 '' 2'`' ''t %''''''>Y' ?` ''' ` '` '''''>'''-'?`_ :,::;.: >::::�::.''::' ' Signed Todd Foster System Representative 2219-B Rowland Avenue 605 N.W.53rd Ave.,Suite A-10 502 D-3 Capital Circle S.E. 5021 Stepp Avenue Savannah,Georgia 31404 Gainesville,Florida 32609 Tallahassee,Florida 32301 Jacksonville,Florida 32216 Phone:(912)303-0310 Phone:(352)378-9777 Phone:(850)656-1705 Phone:(904)737-3511 FAX:(912)303-0390 Fax:(352)377-8225 Fax:(850)656-2327 Fax:(904)737-8553 rnnnnr-trA 44 r tnrfnc400 Savannah Jy stems a Division of Jacksonville Sound&Communications,Inc. January 8, 2007 M.L. Sloan Electric Co. Inc. 2323 Roland Ave Savannah, GA 34104 Re: Silver Ave. Condo JSC Job# S06-053 Dear Sir: We submit the following information and attached data sheets on the proposed equipment for the Fire Alarm System of the above referenced project. MANUFACTURER MODEL DESCRIPTION SIG SG-32SK1-SC DUAL ACTION PULL FOR WP CAST BACKBOX WHE ASWP-2475W-FR WP HORN & WP 75CD STROBE WHE WBB-R WP BOX WHE MIZ-24S-R OR W MINI HORN TEMPORAL OR CONTINUOUS WHE PS-12/24-8MP 8A PWR SPL;Y W/SYNC MOD EDWARDS SYSTEMS SIGA-CTl 1 IN MONITOR MOD SG EDWARDS SYSTEMS SIGA-WTM WF/TS MONITOR,SG EDWARDS SYSTEMS SIGA-CC1 SINGLE SIGNAL MOD 2G EDWARDS SYSTEMS SIGA-PS ANALOG PHOTO HEAD EDWARDS SYSTEMS SIGA-SB4 4" SQ SIGA BASE EDWARDS SYSTEMS SIGA-HFS ANALOG FIXED HEAT EDWARDS SYSTEMS QS1-1-R-1 INTELL 1 LOOP SYS 1 OPT SPACE RED EDWARDS SYSTEMS DLD TWO LINER DIALER MKB ES7-12 7.2AH/12V BATT MKB ES12-12 12AH/12V BATT ADI SF-7550 WP PANEL ENCL ADI SF-7530 WP PANEL ENCL WSP 980 1PR/18 FPL FOR ZONE/NAC WSP 994 1 PR/14 FPL FOR ZONE/NAC ► ` r • Wire will be furnished in accordance with contract plans, specifications and manufacturer's recommendations. Quantities will be furnished in compliance with contract plans and specifications. All equipment will be guaranteed for a period of one (1) year following the date of project acceptance. If you.need any additional information or have any questions, please feel free to contact me at (912) 927-0107. Sincerely, Todd Foster Todd Foster Systems Representative TF/sp Please return 2 copies of approved/disapproved submittals to Jacksonville Sound and Communications,Inc.,Attn:Maryann Taylor at our Jacksonville address 5960 Ogeechee Rd., Unit N 605 N.W. 53rd Ave., Suite A-10 502 D-3 Capital Circle S.E. 5021 Stepp Avenue Savannah, Georgia 31419 Gainesville, Florida 32609 Tallahassee, Florida 32301 Jacksonville, Florida 32216 Phone (912) 927-0107 Phone: (352) 378-9777 Phone: (850) 656-1705 Phone: (904) 737-3511 Fax: (912)927-0179 Fax: (352)377-8225 Fax(850)656-2327 Fax: (904)737-8553 FIRE ALARM*INTERCOM*SOUND SYSTEM*NURSE CALL*AUDIO VISUAL *SECURITY*ACCESS CONTROL*DATA GEORGIA #LU405018 DESIGN, SALE, INSTALLATION, and SERVICE F t FIRE 511-32 Series Die-Cast Metal PULL Manual P71! Station s SIGC M Description Features The SG-32 Series is a family of versatile, high-quality,metal Fire Alarm Pull Stations(red)designed to meet any installation demand. Available in both single • Single or Dual Action and dual action configurations, SG-32 may be configured with either SPST or DP ST contacts. A terminal strip for field connections is provided. The normally • Terminal Connections open contact of each station,which closes when the pull station is activated,is rated for 1 Amp,30VDC. The contacts are gold plated to avoid risk of corrosion. • Gold Plated Alarm Contacts All models in the SG-32 Series have been tested by ULI and found in compliance to the latest requirements of the American's With Disabilities Act(ADA). • Surface or Weatherproof Backbox SG-32 stations from Signal Communications Corporation are available • Optional Auxiliary Alarm Contacts with either hex locks or key reset. Key reset models are available for interchangeable keys. All models mount on a standard, single-gang backbox, Optional Station Colors SigCom model SGB-32S interior surface metal backbox or model SGB-32C, (SG-WP)weatherproof backbox. SG-32 Series stations are also available in optional colors (other than red) for special application. Operation The SG-32 Series is operated by pulling the handle marked "PULL" on the front of the station as far down as it will go. At that point,the station will lock in place and is easily visible from up to 50 feet. The activation handle is reset by opening the station with the hex wrench or key,placing the handle in the normal upright position and relocking the station. On the dual action, the push bar rotates inward allowing the "PULL" handle to be grasped and operated by a single hand. COM cULus MF.A Signal Communications Corporation NYC Approved APPROVED r Spa ''+anions Temperature: -40 to 150F,90°relative humidity @ 100°F Switch Rating: 1 Amp @ 30 VDC 1 Amp @ 125 VAC Pull Station Dimensions: 4 3/4"H x 3 '/4"W x 1.1"D Surface-mount Backbox Dimension: 4 3/4"H x 3 '/4"W x 2 1/4"D(cast and sheet metal) Color: Red with raised white letters,white"PULL"bar with raised red letters Optional Colors: Blue,Yellow or Green Wiring Diagrams SG-32S SG-32CX PULL Screw Screw Terminals Terminals To Fire O To next O 0 O p To next Alarm Control ��` or ELR To FACP{ ■�40,_,M,01i or Panel • Auxiliary J �Iim To next Alarm { device • Circuit or ELR Ordering Information Model# Single Dual Term Hex Key SPST Models SG-32SH2 • SG-32SK2 $' • SG-32SK1 • DPST Models SG-32CXK2 • • • SG-32CXK1 • • • Accessories SGB-32S Interior surface sheet metal backbox red SGB-32C (same as SG-WP)Weatherproof surface die-cast metal backbox and gasket assembly—red SG-GR Scored plastic(acrylic)breakrods(1 dozen to a pack) Please note: All models are supplied with one,scored acrylic breakrod and one hex wrench or key. Customized Logos and Colors The SG-32 Series is designed to provide a customized, die-cast, metal logo or embossed Lexan plastic logos for special applications or unique markings. In addition, optional colors for special applications are available. Consult the factory for more detailed information. G COM Signal Communications Corporation P.O.Box 2588 Woburn,MA 01888 Tel.:781 933 0998 Fox.:781 933 5019 www.sigcom.com COOPER Wheelock Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories r= IrRE Description: Designed for life safety, performance and reliability, Cooper When used in conjunction with Wheelock PS-24-8MC Power Wheelock's cost effective weatherpoof notification appliances Supplies or SM/DSM Sync Modules, the Wheelock weatherproof include: appliances can be synchronized to meet NFPA 72 synchronization Weatherproof Appliances Series requirements.The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync Strobes RSSWP protocol. MTWP horn strobe models are 4-wire appliances; the Horn Strobes ASWP strobes can be synchronized while the audible can be connected Horns AH-24WP,AH-12WP to a coded fire alarm system or can be set to produce any of eight Multitone Horn Strobes MTWP selectable tones. Multitone Horns MT Speaker Strobes ET7OWP Speakers ET-1010 Features: All strobe models are UL dual listed - meeting both UL1638 Approvals include: UL Standards 1971, 1638,464 and 1480 and UL1971 requirements. As dual listed appliances, these California State Fire Marshal(CSFM)and New York City weatherproof strobes, horn strobes and speaker strobes are listed (MEA), Factory Mutual(FM)and Chicago(BFP) . See for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of—31°F to 150°F (-40°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL • Compliance with the following requirements: NFPA, UFC, outdoor test requirements for rain,humidity and corrosion resistance ANSI 117.1, OSHA Part 29, 1910.165,ADA while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 • Weatherproof with extended temperature range of—40°F to strobe spacing tables(up to 185 candela for wall mounting and 177 150°F(-40°C to 66°C)* candela for ceiling mounting). • Dual Listed strobe models (UL 1638 and UL 1971) To enable weatherproof mounting, Cooper-Wheelock provides the • Industry's highest strobe candela options industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting • Synchronization capability using Series SM, DSM Synch to Wheelock weatherproof backboxes on walls or ceilings. The Modules(MTWP and MT-12/24 audible is non-sync) optional WP-KIT allows the weatherproof backboxes(IOB,WPBB or • Models with field selectable tone,dBA and candela settings WPSBB)to be mounted to a recessed electrical box for concealed • conduit installation. For semi-flush installation, the WPA and Wall or ceiling mounting options WFPA kits allow a customer to mount the weatherproof appliances • Surface of semi-flush mounting to a recessed electrical box without the need for an external IN/OUT wiring termination accepting two#12-18 AWG wires •weatherproof backbox. See the Backboxes, Plates and Gaskets at each terminal Table on page three of this document for a summarization of these mounting options and the required accessories. °The series RSSWP,ASWP.MTWP and ET7OWP have UL approval down to-40°F. The AH-24WP,MT-12/24 and the ET-1010 have been ULC tested and approved to -40°F,but not submitted to UL. The AH-12WP has UL/ULC approval to-31°F. 0 "'Ill • litta APPROVED E5946 151-92-E 7125-0785:131(ASWP) S5391 7125-0785:146(ET7OWP) S2652 7125-0785:156(MTWP) 7300-0785:154(RSSWP) I , • NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. F' 'IRE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR kTION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU Ai...iOR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount F .. .- FIRE ■ RSSWP MTWP RSSWP MTWP MT AH iiii 4F4j4.- , ASWP ET7OWP ASWP ET7OWP ET-1010 Strobe Order Code Strobe Order Code Audible Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 AH-24WP-R Red 7416 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-12WP-R Red 7415 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187 Horn Audible Strobe Audible Strobe MT-12/24-R Red 5023 ASWP-2475W-FR Red 9012 lip ASWP-2475C-FR Red 4251 Speaker ASWP-24MCHW-FR Red 5137 ASWP-2475C-FW White 4502 ET-1010-R Red 3135 ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-W White 3137 Multi-tone Strobe ASWP-24MCCH-FW White 5157 IV" '9-2475W-FR Red 8420 Multi-tone Strobe UL Max.Current AH t. '-2475W-FW White 3112 MTWP-2475C-FR Red 4457 24 VDC 12 VDC M l v/P-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 High(99)dBA 0.080 0.192 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 Med(95)dBA 0.043 0.108 Speaker Strobe MTWP-24MCCH FW White 5122 Low(90)dBA 0.021 0.058 ET7OWP-2475W-FR Red 9077 Speaker Strobe ET7OWP-2475W-FW White 3179 ET7OWP-2475C-FR Red 4452 UL Reverberant dBA @ 10 Feet ET7OWP-24185W-FR Red 4885 ET7OWP-2475C-FW White 4454 Watts 1/8 1/4 1/2 1 2 4 8 ET7OWP-24185W-FW White 4891 ET7OWP-24177C-FR Red 4845 ET7OWP-24177C-FW White 4859 ET-1010 77 80 83 86 87 92 94 ET7OWP 78 81 84 87 90 93 95 Candela Ratings UL 1638 UL 1638 RSS,ET7OWP and ASWP Series UL 1971 MTWP UL Max Current @° 77°F @-40°F (Strobe Only) High Med Low Model Number Agency Approvals 2475 30** 180 75 0.138 0.168 0.155 0.150 Strobe UL MEA CSFM FM BFP 135 135 56 0.300 0.355 0.340 0.335 RSSWP-2475 X X X X MCWH * 185 185 77 0.420 0.480 0.465 0.460 RSSWP-24MCWH X * * * * 115 115 47 0.300 0.355 0.340 0.335 RSSWP-24MCCH X * * * MCCH 177 177 73 0.420 0.480 0.465 0.460 Audible Strobe ASWP-2475 X X X X X 24185 185 185 77 0.420 **Wall mount rating only ASWP-MCWH X * * * * 24177 177 177 73 0.420 ASWP-MCCH X * * * Multitone Strobe MTWP-2475 X X X X * UL Max.Current MTWP/MT MT MTWP-MCWH X (Audible) 24 VDC 12 VDC MTWP-MCCH X * * dBA HI STD HI STD Horns/Audibles Horn 0.108 0.044 0.177 0.034 AH-24WP X X X X Bell_ 0.053 0.024 0.095 0.020 AH-12WP X X X X M Time 0.104 0.038 0.142 0.034 MT-12/24 X X X X X Cc .,Horn 0.091 0.035 0.142 0.034 Speaker Strobe Code 3 Tone 0.075 0.035 0.105 0.021 ET7OWP-2475 X X X Slow Whoop 0.098 0.037 0.142 0.035 ET7OWP-185 X Siren 0.104 0.036 0.152 0.030 ET7OWP-177 X Hi/Lo 0.057 0.025 0.114 0.026 *Pending Mounting Accessories i !h Irr � r .$ WFP WFPA IOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Mounting Options: Flush Plates Backboxes,Plates,Gasket Kits WFPA-R Red 4698 Surface Mount Flush WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 WFP-W White 4697 RSSWP Strobes WPSBB WPSBB+WP-KIT WFP Backboxes ET7OWP Speaker Strobes IOB IOB+WP-KIT WFP 10B-R Red 5046 ASWP Horn Strobes WPBB WPBB+WP-KIT WFPA IOB-W White 5047 WPSBB-R Red 9751 AHWP Horns WBB - WFP WPSBB-W White 3033 ET-1010 Speakers WBB - WFP WPBB-R Red 9014 WPBB-W White 4692 MTWP Multitone Horn Strobes IOB IOB+WP-KIT WFP WBB-R Red 2959 Multitone Horn IOB IOB+WP-KIT WFP WBB-W White 2960 — SERIES MTWP APPLIANCES SYNCHRONIZED STROBE Wiring Diagrams OPERATION WITH CODED FACP MTWP 0 0 0 0 Strobe Cu'cuil SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE i Modu W v le IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. NAC l°0 i 0 or PS-12/24-E 0,, Audible Power Circuit FROM TO NEXT FACP Supply 0 PRECEDING + + APPLIANCE APPLIANCE RED MAC it li BLACK " OR EOLR m OR FACP Note: Strobe circuit requires constant voltage. I I 0 C 3 SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ 0 DSM MODULE SINGLE CLASS "A"NAC CIRCUIT STROBE AUDIBLE DSM STROBE SERIES RSSWP,ASWP,AHWP,MTWP AND MT-12/24 NAC SYNC I 0 CIRCUIT APPLIANCES OUT p+OUT I 0 re ■ B+IN I is PRE FROM E PRECEDING ± + TO NEXT E Co MINUS 1 w _ APPLIANCE L— i� APPLIANCE OR Ill OR EOLR FACPo �` 0 AUDIBL9 FACP IN ',MINUS 2 Q+IN 2 l®��a® TROBE /�+OUTz NAC CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. ARCHITECTS AND ENGINEERS SPEC .CATIONS General Weatherproof notification appliances shall be UL listed for outdoor use.Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances)for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices fr-Hearing Impaired).The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using :r exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock i...,unting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of—40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464.The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. T Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480.All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET7OWP.They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required,the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in,patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a ,crate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. ■.,atherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings.Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. 2' -anchport Avenue Member Lc 3ranch, NJ 07740 Phone: (800)631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732)222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S9004 WP 10/06 COOPER Wheelock Series MIZ Mini Horn Appliances SERIES MIZ Description: Features: Wheelock Series MIZ piezoelectric Mini Horns are compact • Approvals include: UL Standard 464, California State Fire electronic alarm appliances that are listed under UL Marshal(CSFM),New York City(MEA), Factory Mutual Standard 464 for Audible Appliances in Public Mode Fire (FM), and Chicago(BFP) Protection Systems. The Series MIZ-24S models provide • Field selectable settings for Temporal (Code 3)or Continu a field selectable Continuous or Code 3 horn tone when ous Horn connected directly to a fire alarm control panel. They can • Synchronized code 3 horn when used with Wheelock Sync also provide a synchronized code 3 horn tone using the Module Wheelock SM, DSM Sync Modules or PS-24-8MC power • Designed to meet or exceed NFPA/ANSI standards supply.The series MIZ appliances are attractive,offer high • Convenient mounting to any standard single-gang box sound output along with low current draw and are ideal for Beauty plugs to cover mounting screws alarm signaling in individual rooms, apartments, hotels, No additional trimplate required for flush mounting •motels and offices. Color choices of red or off-white will blend with any decor. • Fast installation with In/Out screw terminals using#12 to #18 AWG • High sound output with low current draw • Available in red or off-white color Wiring Diagrams (for all models) FROM PRECEDING + + TO NEXT Applications: APPLIANCE - _ APPLIANCE • Individual Rooms 1111 OR FACP OR EOLR • Apartments • Hotels • Motels • Offices Specifications and Ordering Information Order Mounting Agency Approvals Model Code Description Options** UL MEA CSFM FM BFP MIZ-24S-R 8485 24 Volt, Red B X X X x * *PENDING - **Refer to Data Sheet S7000 MIZ-24S-W 8484 24 Volt, White B X X X X * for Mounting Options. General Notes: • Mini Horn models are Listed for indoor use with a temperature range of w.i 32°F to 120°F (0°C to 49°C)and maximum humidity of 93% RH±2%. U1 O, •Rated Input voltage(either filtered DC or unfiltered full-wave-rectified FWR): APPROVED 16-33 VDC(for 24 VDC MIZ-24S models) 55391 151-92-E 7125-0785'161 Architects and Engineers Specifications The notification appliance shall be a Wheelock MIZ-24S audible appliance or approved equal. The Notification Appliance shall be electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support coded systems operation. The anechoic sound pressure measurement on Temporal(Code 3)setting shall be 87 dBA minimum at 24VDC. The anechoic sound ,ssure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC. Operating voltages shall be 24 VDC ig filtered power or unfiltered power supply(full-wave-rectified). All models shall have provision for standard reverse polarity type supervision and IN/OUT wiring using terminals that accept#12 to #18 AWG wiring. The appliances shall be mounted indoors and mount on standard single-gang electrical backboxes requiring no additional trimplates or adapters. Table 1: UL Listed Models and Ranges * RMS current ratings are per UL average RMS method. Reverberant dBA Anechoic dBA UL max current rating is the Regulated Average Per UL 464 @ 10 ft @ 10 ft maximum RMS current within Model UL RMS Mounting the listed voltage range(16-33v Voltage Current* Continuous Code 3 Continuous Code 3 Options for 24v units). For strobes the g (AMPS) UL max current is usually at the dBA dBA dBA dBA minimum listed voltage(16v for 24v units). For audibles the 24 VDC 0.025 83.2 78.8 87.9 87.9 B max current is usually at the MIZ-24S maximum listed voltage (33v UL max* 0.026 85.8 81.3 90.6 89.7 B for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. A WARNING: CONTACT WHEELOCK FOR THE CURRENT"INSTALLATION INSTRUCTIONS"(P84408)AND "GENERAL RMATION"SHEET(P82380)ON THESE PRODUCTS.THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IL JRTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS,INCLUDING: •TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. •FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE CIRCUITS. •THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE. •FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. •CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS,PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters'Laboratories(UL), National Electrical Code(NEC), Occupational Safety and Health Administration (OSHA), local, state,county, province, district,federal and other applicable building and fire standards,guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. INWIiik 2' ',anchportAvenue �'� Member L ,3ranch, NJ 07740 Phone: (800)631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732)222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S1700 MIZ 06/06 is Co WO OP A 3A I�_ M EA L _ _.. .�t....._�. INC. re Alarm Systems Helping People Take AC i nTM POWERPATH TM Description POWERPATH Series PS-12/24-8 is a power limited 8 ampere power supply/charger used to expand the supervised power capability of a Fire Alarm Control Panel (FACP)for Notification Appliance Circuits(NAC)as well as providing auxiliary power to support system accessories.Power Limited refers to the ratings of the output circuits per UL 864 and NFPA 70 (NEC),Article 760. Two Series PS-121248 (2) Class "A" or Class "B" inputs from an FACP and two (2) dry Power Supply trigger inputs are provided to direct and deliver regulated and filtered 12 or 24 VDC via four(4)Class"B",two(2)Class"A"or two (2)Class"B"and one(1)Class"A"NAC Circuits.Each Class"A"or Class"B"ouput has a maximum rating or two(2)amperes.A single output of four(4) amperes can be achieved by paralleling two (2) Class"B"outputs. Series PS-12/248 (Batteries Not Included) POWERPATH Series PS-12/24-8 is compatible with all Wheelock's conventional 12 or 24 VDC Life Safety Notification Appliances and with its Patented BUILT-IN SYNCHRONIZED MODE feature, it can control and operate all of Wheelock's Synchronized OW! Notification Appliances.Additionally,the horn may be silenced while maintaining strobe activation. -: Features •Approvals(PS-12/24-8):UL 864,MEA,CSFM • Input and output synchronization (including •NFPA-72 COMPLIANT pass through) •Compatible with 12 or 24 VDC FACP • FACP NAC supervision steered to either input • 115 VAC @ 60Hz and 3.2 amps input voltage #1 or#2 •8 amperes rated supply current @ 12 or 24 VDC • Common input and output trouble circuit • Filtered and regulated power supply outputs • Input and output LED indicators • Field selectable 12 or 24 VDC outputs •AC fail supervision(Form"C"contacts rated @ • Each Class"A"or Class"B"output has a 1 amp @ 24 VDC or 115 VAC maximum rating of two (2)amperes. •Battery presence and low battery supervision •50 mA of resettable(internal or remote)auxiliary power (Form"C"contacts rated @ 1 amp @ 24 VDC •Accepts 2 Class"A"or 2 Class "B" NAC circuit inputs or 115 VAC •Additional activation options are: NC contacts or open •Ground fault detection collector of a transistor •Thermal and short circuit protection with •Programmable EOL Resistor Supervised NAC Circuit auto reset Outputs (4 Class"B"or 2 Class"A"or 1 Class "A"and 2 •Built-in battery charger for sealed lead acid Class"B")with a maximum 2 amperes per circuit or gel type batteries •Class 2 rated power limited outputs •Automatic switch over to stand-by batteries • 2 Class"B"Outputs may be paralleled for more power when AC fails on a circuit(Total 4 Amperes on the circuit) •Zero voltage drop when switching to battery •2 Outputs may be paralleled for more power on a circuit stand-by (total of 4 amperes on the circuit) •Circuit breaker battery protection •Dip switch selectable options • Unit includes power supply,red enclosure, •Code 3 (Temporal)option cam lock,open frame transformer and •Steady output option battery leads • Built-in Synchronization Mode • Size: 15.5" H x 12.5"W x 4.5" D Copyright 2001 Wheelock, Inc. All rights reserved. Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH Series PS-2/24-8,or equivalent.The unit shall be a stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s)(NAC).The unit shall be UL 864 approved for power limited operation of its outputs and comply with NFPA70(NEC),article 760.The power supply shall be listed under UL Standard 864,and have MEA and CSFM approvals. The power supply shall be activated by a standard Notification Appliance Circuit(NAC)from any Fire Alarm Control Panel(FACP)or a"Dry contact"closure.The unit shall be an 8 ampere, 12 or 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 9 to 30 VDC.The primary application of the unit shall be to expand a fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories.The power supply shall provide four Class "B", two Class "A", or two Class "B" and one Class "A" NAC circuit(s). The unit shall also supply resettable auxiliary power of not less than 50 mA at 24 VDC.The power supply shall be capable of charger batteries of up to 12 ampere hours per NFPA 72 (1999). Input activation shall be from not less than two NAC circuits or Dry Contact closures.These inputs shall have the capability of being directed to any combination of the four MAC circuit outputs.Each NAC circuit output shall be rated at 2 amperes and shall be programmable to generate a steady or Temporal(Code 3)output and or a synchronized strobe or horn output.The unit shall have the capability of achieving a four ampere NAC circuit output simply by paralleling two of the NAC circuit outputs. The power supply shall provide independent loop supervision for either Class"A"or Class"B"FACP NAC circuits and shall have the capability to"steer"all alarm or trouble conditions to either incoming NAC circuit.The unit shall have common output terminals and common trouble input terminals.The power supply shall be powered from a 115 VAC, 60 Hz source with a current consumption of 3.2 amperes. The unit shall incorporate short circuit protection with auto reset.The power supply shall incorporate a built-in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure.The charger shall incorporate circuit breaker protection for the batteries and have the ability to report low battery and/or no battery condition(s).Stand by current for battery back up shall be 75 mA. The cabinet dimensions shall be 15.5"H x 12.5"W x 4.5"D. .i. WARNING:PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS AND WARININGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Specifications and Ordering Information Model Number Order Code Input Voltage/Current PS-12/24-8 8114 115 VAC,60 Hz;3.2 amps PS-12/24-8E 8218 220 VAC (Note:no agency approvals) Output NAC Circuits Output Voltage/Current Four(4)Class"B" 12/24 VDC @ 2 amps per Circuit Two(2)Class"A"or 8 amps maximum available One(1)Class"A"and Two(2)Class"B" Standby Current 75 mA Maximum Loop Resistance 100 Ohms Standby Batteries Standby Time Alarm Output Aux Output Current Total Amps/Minutes 24 VDC/12 AH 24 Hours 8 Amps/15 Minutes 50 mA • (uses two(2)12 VDC batteries in series) 60 Hours 8 Amps/15 Minutes — 24 Hours 8 Amps/15 Minutes 50 mA 12 VDC/12 AH 60 Hours 8 Amps/15 Minutes -- 24 VDC/7 AH 24 Hours 8 Amps/15 Minutes (uses two(2)12 VDC batteries in series) 12 VDC/7AH 24 Hours 8 Amps/15 Minutes NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Distributed By: National Sales Office Made in USA 800-631-2148 Canada 800-397-5777 v _ E-Mail: Info @wheelockinc.com http://www.wheelockinc.com Member 273 Branchport Avenue• Long Branch, NJ 07740 •TEL: 732-222-6880 • FAX:732-222-2588 S9001 3/01 dm" SIGA-CT1 Single Input Module Product description Personality code 2:N.O. alarm delayed latching(Class B): Personality code 2 operates the same as personality code 1 except that contact closure must be maintained for Iii I approximately 16 seconds before an alarm signal is generated. Personality code 2 is only for use with non-retarded waterflow O 0 0 0 alarm switches. 8 7 Personality code 3: N.O. active non-latching(Class B):A contact closure causes an active signal instead of an alarm Osignal and does NOT latch at the module. Personality code 3 is typically used for monitoring fans, dampers, doors, etc. Personality code 4: N.O. active latching(Class B):A contact closure causes an active instead of an alarm event,which is 0 0 latched at the module. Personality code 4 is typically used for 4 3 2 1 monitoring supervisory and tamper switches. © CD Warnings 1. This module will not operate without electrical power.As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection The SIGA-CT1 Single Input Module is a component of the specialist. Signature Series.The SIGA-CT1 is an analog addressable device used to connect a Class B, normally open, alarm, 2. This module does not support conventional smoke supervisory, or monitor type dry contact initiating device circuit detectors. (IDC)to a Signature loop controller. One device address is required. Specifications The SIGA-CT1 can be used for alarm, supervisory, or monitor Operating voltage range: 15.2 to 19.95 Vdc type applications. This is determined by a personality code that Standby current:250 IAA is downloaded to the module by the loop controller during Activated current:400 p ■ system configuration. Operating temperature range:32 to 120°F(0 to 49°C) The loop controller assigns an address to the SIGA-CT1 Operating humidity range: 0 to 93% RH automatically.A custom address can also be assigned to the Storage temperature range:-4 to 140°F(-20 to 60°C) module via laptop computer. No addressing switches are used. Construction: High impact engineering polymer Shipping weight: 5.1 oz(145 g) i'` Diagnostic LEDs provide visible indication of the status of the Compatible electrical boxes module when the cover plate is removed: North American 2-1/2 in (64 mm)deep 1-gang box • Normal: green LED flashes Standard 4 in square box 1-1/2 in(38 mm)deep with • Alarm/active: red LED flashes 1-gang cover Initiating device circuit(IDC) Mounting EOL resistor value: 47 KS2, UL listed The SIGA-CT1 can be mounted in a North American 2-1/2 in Max. circuit resistance(per channel): 50 S2(25 S2 per wire) (64 mm)deep 1-gang box or a standard 4 in square box 1-1/2 Max. circuit capacitiance (per channel): 0.1 µF in (38 mm)deep with 1-gang cover.The terminal blocks accept 12, 14, 16, or 18 AWG wire(2.5, 1.5, 1.0, or 0.75 sq mm). Installation instructions Sizes 16 and 18 are preferred. Note:The SIGA-CT1 is shipped from the factory as an System controller compatibility assembled unit; it contains no user-serviceable parts and The SIGA-CT1 requires the Signature loop controller.The loop should not be disassembled. controller downloads the personality code which determines To install the module: how the module operates.The following personality codes can be downloaded to the SIGA-CT1. 1. Verify that all field wiring is free of opens, shorts,and Personality code 1: N.O. alarm latching(Class B): Personality ground faults. code 1 is assigned to input channels 1 and 2 at the factory. 2. Make all wiring connections as shown in the wiring Personality code 1 configures the module for Class B normally diagram. open dry contact initiating devices(e.g., pull stations, heat detectors, etc.). When the N.O. input contact of an initiating 3. Write the address assigned to the module on the label device is closed, an alarm signal is sent to the loop controller provided and apply the label to the module. Peel off the and the alarm condition is latched at the module. removable serial number label from the module and apply it to the appropriate location in the serial number logbook. Installation Sheet 17JAN03 © P/N: 387021P REV:7.0 SIGA-CT1 -Single Input Module 1 /4 4. Using the 4-24 x 1/2 in (13 mm)self-tapping screw provided, mount the wall plate to the module. al %. 5. Using the two 6-32 x 1/2 in (13 mm)machine screws / Compatible electrical box provided, mount the module to the electrical box. f Notes 1116110* 1. If a 2 in (51 mm) 1-gang box is used, conduit can enter the �' electrical box through only one knock-out hole. I 2. If a 2-112 in(64 mm) 1-gang box is used, conduit can enter 1 1 �1 1 1 Wall plate,white the electrical box through one or both knock-out holes. ,I l� I1 � (1-gang) 3. Wire in accordance with NFPA 70,National Electrical PIT�y V, Code. Wire stripping guide BSI MOW__ a 1/4 in(-6 mm) I. ►{ Mogr" Strip 1/4 in (about 6 mm)from the ends of all wires that Q connect to the terminal block of the module. Caution: Exposing more wire may cause a ground fault. Q Exposing less wire may result in a faulty connection. ,,14 Wiring diagram 141 4 Style B(Class B) 411•1► [1][2][4] _ � Typical N.O. TB2 initiat ing device UUULC listed © 47 kO EOL Red LED i Green LED (Alarm/Active) I 4 3 2 ®1 I (normal) TB1ff�l®& T ©i l--== _ _I DATA IN (+) II J (+) DATA OUT (-) w (—) From Signature controller [3] To next device or previous device Notes [4] Maximum 10 Vdc @ 350 IA [1] Maximum 25 Q.resistance per wire 5. All wiring is power-limited and supervised [2] Maximum 12 AWG (2.5 sq mm)wire;minimum 18 AWG 6. This module will not support 2-wire smoke detectors (0.75 sq mm)wire [3] Refer to the Signature loop controller installation sheet for wiring specifications P/N: 387021P REV: 7.0 17JAN03 Installation Sheet 2/4 SIGA-CT1 -Single Input Module I , Security In:el' gent Input/Outou: . Overview Standard Features The SIGA-MM1 Monitor Module and SIGA-WTM Waterflow/Tamper • Monitor and waterflow/tamper applications Module are part of GE Security's Signature Series system.They are Includes Alarm with delayed latching(retard)for waterflow intelligent analog addressable devices used to connect one or two applications,Supervisory,and Monitor. Class B normally-open Alarm,Supervisory,or Monitor type dry • Non-volatile memory contact Initiating Device Circuits(IDC).The function of the SIGA-MM1 Permanently stores serial number,type of device,and job and SIGA-WTM is determined by the factory loaded"personality number.Automatically.updates historic information including code". hours of operation,last maintenance date,number of alarms The input modules gather analog information from the initiating and troubles,and time and date of last alarm. devices connected to them and convert it into digital signals.The • Automatic device mapping module's on-board microprocessor analyzes the signal and decides Each module transmits wiring information to the loop controller whether or not to input an alarm. regarding its location with respect to other devices on the circuit. The microprocessor in each module provides four additional ben • Electronic addressing efits-Self-diagnostics and History Log,Automatic Device Mapping, Permanently stores programmable address;there are no Stand-alone Operation and Fast,Stable Communication. switches or dials to set.Addresses are downloaded from a PC,or the SIGA-PRO Signature Program/Service Tool. • Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time.Less sensitive to line noise and circuit wir- ing properties;twisted or shielded wire is not required. • Ground fault detection by address Detects ground faults right down to the device level. • Designed for high ambient temperature operation Install in ambient temperatures up to 120°F(49°C). rte. «..� n N'1OdL! eS les SIGA_MM1 Ei. SIGA-OTM it • • ,i,(ini 1! - li ., . • 0 r9hl ` Patented Se9 4.—7.-- A..44111F !et 85001-0297 Issue 5 Not to be used for installation purposes.Page 1 of 4 , 1 Application Installation The duty performed by the SIGA-MM1 and SIGA-WTM is determined The SIGA-MM1 and SIGA-WTM modules mount to North American by their factory assigned sub-type code or"Personality Code". 2-1/2 inch(64 mm)deep one-gang boxes and 1-1/2 inch(38 mm) AGA-WTM NORMALLY-OPEN ALARM-DELAYED LATCHING(Fac deep 4 inch square boxes with one gang covers and SIGA-MP tory set Personality Code 2)-Assigned to one circuit. Configures mounting plates.The terminals are suited for#12 to#18 AWG circuit 1 for Class B normally-open Waterflow Alarm Switches.An 12.5 mm to 0.75 mm 2)wire size. ALARM signal is sent to the loop controller when the input contact is GE Security recommends that this module be installed according to closed for approximately 16 seconds.The alarm condition is latched latest recognized edition of national and local fire alarm codes. at the module. Electronic Addressing-The loop controller electronically addresses SIGA-WTM NORMALLY-OPEN ACTIVE-LATCHING(Factory set each module,saving valuable time during system commissioning. Personality Code 4)-Assigned to one circuit.Configures circuit 2 Setting complicated switches or dials is not required. Each module for Class B normally open dry contact Supervisory and Tamper has its own unique serial number stored in its on-board memory. Switches.An ACTIVE signal is sent to the loop controller when the The loop controller identifies each device on the loop and assigns a input contact is closed.The active condition is latched at the mod- "soft"address to each serial number.If desired,the modules can be ule. addressed using the SIGA-PRO Signature Program/Service Tool. SIGA-MM1 NORMALLY-OPEN ACTIVE-NON-LATCHING(Factory Personality codes are assigned by the factory.No user configura- set Personality Code 3)-Assigned to one circuit.Configures circuit tion is required for these modules. 1 for Class B normally-open dry contact monitoring input such as from Fans,Dampers,Doors,etc.An ACTIVE signal is sent to the loop controller when the input contact is closed.The active condition is not latched at the module.Compatibility Compatible electrical box The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Warnings & Cautions rl Wall plate,white This module will not operate without electrical power.As fires fre- . (1-gang) quently cause power interruption,we suggest you discuss further �� i safeguards with your local fire protection specialist. '�'' t Testing & Maintenance .,*11 Q The module's automatic self-diagnosis identifies when it is defective •, and causes a trouble message.The user-friendly maintenance pro- Fl '• gram shows the current state of each module and other pertinent messages.Single modules may be turned off(de-activated)tempo- 4 rarily,from the control panel.Scheduled maintenance(Regular or ,��,,,� Selected)for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ).Refer to current NFPA 72 and ULC CAN/ULC 536 standards.Availability of maintenance features is dependent on the fire alarm system used. Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes.Page 2 of 4 ■ Typical Wiring The module will accept#18 AWG(0.75mm2),#16(1.0mm2),#14 AWG(1.50mm21,#12 AWG(2.50mm2) wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance _ 0.1NF per Circuit _ _�_ �_� For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm2) #16 AWG(1.00 mm2) 4,000 ft(1219 ml #14 AWG(1.50 mm2) #12 AWG(1.50 mm2) Typical N.O.Waterflow Contact Typical Supervisory Contact Typical N.O.Monitor Contact INPUT l INPUT 2 1 1 win 11 I-I 4 4 AAA Style B(Class B) IMP TB2 lib i) TB2 ntom►) j I Style B(Class B) �� B•7 • • UUULC Listed UL/ULC Listed 9 7 6 5 47KR EOL 47KR EOL AAA Q4 • • • UL/ULC Listed 47KS2 EOL Red LED Green LED Red LED 1 Green LED (Alarm/Active) 4 C C 4 e. (Normal) (Alarm/Active) , (Normal) ` ® I: {DATA IN(+) � ' DATA OUT(-11. f DATA IN(+) 1).DATA OUT(+) DATA IN(-) , DATA OUT(-)1 l DATA IN(-) 10.DATA OUT(-) v From Signature Controller To Next Device From Signature Controller To Next Device or Previous Device Q or Previous Device Q Model S(GA-WTM Model S1GA-MM1 Notes /1\ Maximum 25 ohms resistance per wire. Maximum#12 AWG(2.5mm2)wire.Min.#18(0.75mm2) ARefer to Signature Loop Controller Installation Sheet for wiring specifications. /4\ Maximum 10 Vdc @ 350pA. 5) All wiring power limited and supervised. 6) This module will NOT support 2-wire smoke detectors. Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes.Page 3 of 4 Security u.5. Specifications T 888-378-2329 F 866-503-3996 Catalog Number SIGA-MM1 SIGA-WTM Canada Description - Monitor Module Waterflow/Tamper Module T 519 376 2430 Type Code 48(factory set 49(factory set F 519 376 7258 personality code 3) personality code 2,4) Asia Address Requirements Uses One Module Address Uses Two Module Addresses T 852 2907 8108 Operating Current Standby=250pA; Standby=396pA; F 852 2142 5063 Activated=400pA Activated=680pA Australia Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) T 61 3 9259 4700 Construction&Finish High Impact Engineering Polymer one-gang front plate-White F 61 3 9259 4799 Storage and Operating Operating Temperature:32°F to 120°F(0°C to 49°C) Europe Environment Storage Temperature:-4°F to 140°F(-20°C to 60°C) T 32 2 725 11 20 Humidity:0 to 93%RH F 32 2 721 86 13 LED Operation -W - On-board Green LED-Flashes when polled On-board Red LED-Flashes when in alarm/active Latin America Both LEDs-Glow steady when in alarm(stand-alone) T 305 593 4301 F 305 593 4300 Compatibility Agency Listings Use With Signature Loop Controller UL,ULC,CSFM,MEA Mounting North American 2-1/2 inch(64 mm)deep one-gang boxes and 1- www.gesecurity.com 1/2 inch(38 mm)deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. 2006 General Electric Company All Rights Reserved Signature Series is a Trademark Ordering Information of GE Security. Catalog Description Ship Wt Number lbs{kg( SIGA-MM1 Monitor Module-UL/ULC Listed 0.4(.15) SIGA-WTM Waterflow/Tamper Module -UL/ULC Listed Accessories 27193-11 Surface Mount Box-Red,1-gang 1.0(0.6) 27193-16 Surface Mount Box-White,1-gang MFC-A Multifunction Fire Cabinet 7.0(3.1) -Red,supports Signature Module Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) .106 • Imagination at work Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes.Page 4 of 4 wiNN■rSIGA-CC1 Single Input Signal Module Product description Warnings 1. This module will not operate without electrical power.As fires frequently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. 0 e 2. This module does not support conventional smoke detectors. Specifications O Operating voltage range:15.2 to 19.95 Vdc Standby current 223µA Activated current:100µA 0 0 Output ratings 24 Vdc:2 A 25 Vac audio:50 W 70 Vac audio:35 W �-11 EOL resistor value:47 kfl Max.circuit resistance:refer to manual Max.circuit capacitance:0.1 µF Operating temperature:32 to 120°F(0 to 49°C) The SIGA-CC1 Single Input Signal Module is a component of the Operating humidity:0 to 93% RH Signature Series.The SIGA-CC1 is an analog addressable device Storage temperature:-4 to 140°F(-20 to 60°F) used to connect a supervised output circuit to the riser bus.The SIGA- Construction:High impact engineering polymer CC1 does not provide supervision of the riser;the fire alarm panel Shipping weight:7.7 oz.(218 g) must provide this function. Upon command from the loop controller,the Compatible electrical boxes SIGA-CC1 connects the output circuit to the riser input which can be North American 2.5 in(64 mm)deep 2-gang box 24 Vdc to operate polarized audible and visible signals,25 V or 70 V to Standard 4 in(101.6 mm)x 1.5 in(38 mm)deep square box with operate audio evacuation circuits,or telephone audio.One device a 2-gang cover address is required. The loop controller assigns an address to the SIGA-CC1 automatically. Installation instructions A custom address can also be assigned to the module via laptop computer.No addressing switches are used. Note:The SIGA-CC1 is shipped from the factory as an assembled Diagnostic LEDs provide visible indication of the status of the module unit;it contains no user-serviceable parts and should not be disassembled. when the cover plate is removed: • Normal:green LED flashes To install the module: • Alarm/active:red LED flashes 1. Verify that all field wiring is free of opens,shorts,and ground Mounting faults. The SIGA-CC1 can be mounted in a North American 2-1/2 in(64 mm) 2. Make all wiring connections as shown in the wiring diagram. deep 2-gang box or a standard 4 in square box 1-1/2 in(38 mm)deep 3. Write the address assigned to the module on the label provided with a 2-gang cover.The terminal blocks accept 12,14, 16,or 18 AWG and apply the label to the module.Peel off the removable serial wire(2.5,1.5,1.0,or 0.75 sq mm).Sizes 16 and 18 are preferred. number label from the module and apply it to the appropriate System controller compatibility location in the serial number logbook. The SIGA-CC1 requires the Signature loop controller.The loop 4. Using the 4-24 x 5/16 in(8 mm)self-tapping screw provided, controller downloads the personality code which determines how the mount the wall plate to the module. module operates.The following personality codes can be downloaded 5. Using the four 6-32 x 1/2 in(13 mm)machine screws provided, to the SIGA-CC1. mount the module to the electrical box. Personality code 5:Riser selector(single input):The SIGA-CC1 is Note:Wire in accordance with NFPA 70 National Electrical Code. assigned personality code 5 at the factory.This configures the module as a riser selector for signal power(24 Vdc)or audio evacuation(25 or Wire stripping guide 70 Vac).Since the module is not used for telephone audio,the ring- tone generator is disabled for this personality code.The output circuit is monitored for open or shorted wiring.If a short exists,the control 111111111 panel inhibits the activation of the audible or visible signal circuit,so 1/4 in(-6 mm) I- . that the riser is not connected to the wiring fault. Personality code 6:Riser selector(single-input)ring-tone:Personality Strip 1/4 in(about 6 mm)from the ends of all wires that connect to the code 6 configures the module as a telephone riser selector.When a terminal block of the module. telephone handset is plugged into its jack or lifted from its hook,the module generates its own ring-tone signal.A separate ring-tone riser is unnecessary.The module sends this signal to the control panel to Caution:Exposing more wire may cause a ground fault.Exposing less indicate the presence of an off-hook condition,and waits for the wire may result in a faulty connection. system operator to respond to the call.When the system operator responds,the ring-tone signal is disabled. Installation Sheet 17JAN03 © P/N: 387022P REV: 7.0 SIGA-CC1 -Single Input Signal Module 1 /2 Transient protection caution ° 0 0,1 Bipolar Transient Protector(P/N 235196P) O ; ' t The SIGA-CC1 requires transient protection for installations that O° 0."""1004‘4e* connect electromechanical bells or horns to output circuits.The , module's circuitry requires a Bipolar Transient Protector(P/N 235196P) O° t for protection against transient spikes caused by the inductive load of z�r �, ' bells or horns. \� ®moo Connect the bipolar transient protector assembly across the terminals 11�.1 of the bell or horn electrically closest to the module.The bipolar No ' -.111‘ft" transient protector is not polarity-sensitive. Q- ,. •� • Locate bells and homs at least 6 ft(1.83 m)from the module. ®ap Wiring diagram Personality code r I I �' typical l speaker circuit Personality code 6: Ian Ell typical telephone circuit Transient protection (see"Transient protection Personality codes 5: o caution"above typical notification lio co., appliance circuit Style Y(Class B) [1] [2] [5] [8] t O �+ O I 10 9 UUULC listed © 47K52 EOL Red LED ►o o 4 Green LED (alarm/active) 8 7 6 5 4 3 2 1 (normal) OO aDC Th j—mmmaD C 1 To next device or ■ Riser out(+) EOL resistor supplied • Riser out(-) with UUULC listed From UL/ULC listed [5]1 Riser in(+) > control panel control panel 11 Riser in (-) From Signature controller J Data in(+) > n Data out(+) or previous device l Data in(-) > J —' Data out(-) } To next device [3] [4] Notes [5] Supervised and power-limited when connected to power limited source. If non-power limited,then all power limited wiring in box [1] For maximum wire resistance,refer to the appropriate technical must use FPL,FPLR,or FPLP cable or equivalent per NEC. reference manual Power limited marking must be eliminated. [2] Maximum 12 AWG(2.5 sq mm)wire;minimum 18 AWG(0.75 sq 6. This module does not support 2-wire smoke detectors mm)wire 7. Polarity at terminals 9 and 10 on notification appliance,telephone, [3] See the Signature loop controller installation sheet for wiring and speaker circuits shown in supervisory condition.Connect as specifications shown in diagram.Polarity reverses on alarm. Supervised and power-limited [8] For EN54 applications,an RFK1 must be added to the output circuit P/N: 387022P REV: 7.0 17JAN03 Installation Sheet 2/2 SIGA-CC1 -Single Input Signal Module T!.t EDWARDS SYSTEMS TECHNOLOGY INTELLIGENT INITIATING DEVICES b y 4 QS4((41 EST2 EST3 111C-3/FCC Intelligent Duct Smoke Detector Housing ii - Model SIGA-DH 11 Features ■ Suitable for high air velocity duct applications Up to 4000ft/min.(20.3 m/sec.)with Photoelectric Detector. r Standard Signature Series detectors Designed for use with standard 4D,3D,and Photoelectric Signature Series smoke detectors.Does not require"special" duct smoke heads. ✓ Standard,relay,or isolator detector base Detector plugs-into base then easily installs into housing. IL Install in ducts up to 10 ft.(3.05 m)wide ULC nnE,e, ti) ✓ Remote LED and test station accessories __ ✓ Designed and manufactured to ISO 9001 standards Intelligent Duct Smoke Detectors Compatible Signature Series detectors includethe SIGA-IPHS 4D Multisensor Smoke Detector with THREE INTEGRATED SENSING Description TECHNOLOGIES.It combines Ionization,Photoelectric and Heat The SIGA-DH Duct Smoke Detector Housing is specially engi- sensors and processes and analyzes information from each sensor separately using dynamic filters.Also compatible are the SIGA- neered to exploit all the capabilities of Signature Series intelligent PHS 3D Multisensor Detector and the SIGA-PS Photoelectric photoelectric and multisensor smoke detectors.ESTSignature Detector.The installerselects the alarm sensitivity level from the Series detectors gather analog information from each of their one detector's wide 0.67 to 3.7%sensitivity range window.Five settings or more sensing elements and converts it into digital signals.The are available from within the range. detector's onboard microprocessor measures and analyzesthese signals.It compares them to historical readings,time patterns and Environmental Compensation known characteristics to make an alarm decision.Digital filters and Detection sensitivity for Signature Series detectors is virtually complex Algorithms are applied for optimum detector accuracy. independent of their installed environment and their physical Unwanted alarms are virtually eliminated. condition.Each sensing element adapts to long-term changes Each duct housing is packaged with detailed installation instruc- caused by dirt,humidity,aging etc.Every 8.6 minutes the detector tions,gaskets and a self-adhesive drilling template for locating and adjusts and updatesthesensitivity(/o t.Ever ation)ambient mounting the detector.The large access door is completely information neforits smoke sensing element.Every 68 minutes this removable to allow fast detector installation and field wiring information is written to its permanent memory. connections.The 16 gauge steel housing is finished in red baked The detector's alarm sensitivity setting selected by the installer enamel for easy identification.Five one-gang knockouts on the floats up or down to remain constant relative to the changing housing provide a convenient location for mounting intelligent baseline.This is called environmental compensation. Signature Series modules. Identification of Dirty or Defective Detectors The SIGA-DH Duct Housing comes with a 6 inch(150 mm)exhaust Each detector automatically identifies when it is polluted and tube.Air sampling tubes are available in lengths from 8 inches(200 causes a"dirty detector"message.The detector's sensitivity mm)to 10 feet(3048 mm)and must be ordered separately. measurement can also be transmitted to the loop controller.This Compatible smoke detectors,mounting bases,and accessories are measurement satisfies NFPA sensitivity measurement requirements. listed in the Ordering Information.Refer to individual device The detector's internal components are self-supervised.Up to 32 catalog literature pages for more detail. trouble codes are generated and displayed for diagnostics. EDWARDS SYSTEMS TECHNOLOGY U.S.SALES:SARASOTA,FL 941-739-4638;FAX 941-727-1214 • CANADA SALES:OWEN SOUND,ON 519-376-2430;FAX 519-376-7258 INTERNATIONAL SALES:905-270-1711,FAX 905-270-9553 • CORPORATE HEADQUARTERS:CHESHIRE,CT • U.S.MANUFACTURING:PI1TSFIELD&NEWPORT,ME Issue 4 Literature Sheet #85001-0325 Page 1 of 4 Not to be used for installation purposes. For the most current literature and updates visit www.est.net. Non-Volatile Memory Signature Duct Detector Accessories iature Series smoke detectors permanently store a serial _mber,type of device and job number.Automatic updates of Duct Detector Air Sampling Tubes historic information including hours of operation,lastmaintenance One air sampling inlet tube must be ordered for each duct smoke date,number of alarms and troubles,time and date of last alarm detector housing.Refer to Ordering Information for available are available.In the unlikely event that an unwanted alarm does lengths. take place,the history file can be called up to help isolate the Detector Mounting Bases problem and prevent it from happening again. One detector mounting base must be ordered for each duct smoke Electronic Addressing Er Device Mapping housing.Removing a detector from its base(except isolator base) The Signature loop controller automatically addresses each does not affect other devices operating on the same data loop. detector to save valuable time during system commissioning. Available bases are: Setting complicated switches or dials on each intelligent device is Standard Base SIGA-SB-This is the basic mounting base.The not required.If desired,the detectors can be custom addressed SIGA-LED Remote LED is supported by the Standard Base. using the Signature Series Data Entry Program. Relay Base SIGA-RB-This base includes a relay.Normally open The wired circuits between each device can be examined using the or closed operation is selected during installation.The dry contact data entry program along with the self-mapping feature built into is rated for 1 amp @ 30 Vdc(pilot duty).The relay's position is all Signature Series devices.With its graphic support,layout or supervised to avoid accidentally jarring it out of position.The SIGA- "as built"drawing information showing wire branches(T-taps), RB can be operated as a control relay if programmed to do so at device types and their address are stored on disk for printing hard the control panel(EST3 V.2 only).The Relay Base does not copy.This takes the mystery out of the installation.The preparation support the SIGA-LED Remote LED.Relay bases are not affected of"as-built"drawings is fast and efficient. or activated by the SIGA-DTS Duct Test Station. Device mapping also allows the Signature loop controller to Isolator Base SIGA-IB-This base includes a built-in line fault discover: isolator.A detector must be installed for it to operate.The integral -unexpected additional device addresses isolator relay is controlled by the detector or the loop controller.A -missing device addresses maximum of 96 isolator bases can be installed on one loop.The changes to the wiring in the data loop. Isolator Base does not support the SIGA-LED Remote LED. Stand-Alone Operation Alarm LED Indicator On-board intelligence permits Signature devicesto operate in stand- The SIGA-LED Alarm Indicator is suitable for use with the SIGA-SB alone mode.Should loop controller CPU communications fail for detector base only.A maximum of one can be operated for each -re than four seconds,all devices on that circuit(loop)go into detector.It features a red LED on a one-gang plastic plate and can d-alone mode.The loop acts like a conventional alarm receiving be installed remote or directly on the SIGA-DH Duct Housing. circuit.Each detector on the loop continues to collect and analyze Duct Test Station information from its surroundings.The detector alarms if the preset The SIGA-DTS Duct Test Station uses a key switch along with an smoke obscuration level is reached and causes a loop alarm.If the integral intelligent input module mounted on a two-gang plastic detector is mounted to a relay base,the relay operates.Similarly,if plate.It is supplied with two keys and features a red alarm LED. it is mounted to an audible base,the on-board horn sounds. When the key is turned to the"TEST"position,the LED lights and Quality and Reliability the integral module remotely inputs a duct detector test alarm.The EST detectors are designed and manufactured in North America to actions and sequences programmed at the control panel to ISO 9001 standards.All electronics utilize surface mounttechnol- activate dampers and other smoke control measures,are easily ogy(SMT)for smaller size and greater immunity to RF noise.A tested.Detector relay bases are not affected or activated.Resetting conformal coating is used for corrosion resistance and all critical the control panel clears the test and returns the system to normal. contacts are gold plated. The key cannot be removed when in the"TEST"position. The DuctTest Station mounts to standard 2-inch deep North - Cc� ri g American two-gang and 4-inch square electric boxes and European 100 mm square boxes. The detector mounting bases and test station will accept#18 AWG Air Velocity Test Kit (0.75mm ),#16(1.0mm ),#14 AWG(1.50mm )and#12 AWG The 6263-SG Air Velocity Test Kit is specially designed to interface (2.5 mm )wire sizes.Note: #14 AWG(1.5 mm 2)is not recommended to the SIGA-DH Duct Housing.It is used to test or confirm the air due to difficulty of installation.See Loop Controller and Detector velocity in HVAC ducts where the duct housing is installed. catalog sheetsfor detailed wiring requirementspecifications. EDWARDS SYSTEMS TECHNOLOGY Page 2 of 4 Literature Sheet #85001-0325 Issue 4 Not to be used for installation purposes. For the most current literature and updates visit www.est.net. Specifications SIGA-DH Duct Housing(NOTE:The SIGA-DH Duct Housing is NOT WEATHERPROOF or DUST TIGHT.) Dimensions 7-3/8 inches(188mm)W x 7 inches(178mm)H x 5 inches(127mm)D Material and Finish 16 Gauge Cold Rolled Steel,Red-Baked Enamel Conduit Knockouts Combination 1/2 inch&3/4 inch Agency Approvals UL,ULC,MEA,CSFM Compatible Smoke Detectors SIGA-PS SIGA-PHS SIGA-IPHS Air Velocity Range 300 to 4000 ft/min.(1.5 to 20.3 m/sec) 300 to 1000 ft/min. (1.5 to 5.0 m/sec) Photoelectric- Ionization-Unipolar Photoelectric- Light Scattering Principle Photoelectric- Smoke Sensing Element(s) Light Scattering Principle Light Scattering Principle Heat- 135°F(57°C)Fixed Temperature Heat-Alarms at 65°F(35°C) change in ambient temp. Temp:32-120°F(0°to 49°C) Temperature: 32- 100°F(0-38°C) Operating Environment Humidity:0 to 93%RH, Humidity:0 to 93%RH,non-condensing non-condensing Storage Environment Temperature:-4 to 140°F(-20 to 60°C);Humidity:0 to 93%RH,non-condensing 0.67%to 3.70%obscuration/foot ULI/ULC Sensitivity Range 0.67%to 3.77%obscuration/foot(305mm) (305mm) User Selected Alarm Sensitivity Least Sensitive:3.5%; Less Sensitive:3.0%; Normal: 2.5%;More Sensitive:2.0%;Most Sensitive: 1.0% Settings Pre-alarm Sensitivity 5%increments,allowing up to 20 pre-alarm settings Electrical and Physical Characteristics Refer to individual detector catalog sheets Compatible Mounting Bases SIGA-SB Standard Base,SIGA-RB Relay Base,SIGA-IB Isolator Base Compatible Remote LED SIGA-LED(LED flashes when in alarm) Controller Compatibility SIGNATURE Loop Controller Addressing Restrictions Uses one Input Device Address SIGA-DTS Duct Test Housing Operating Current Standby=250pA;Activated=400pA Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Replacement Key p/n-P-037449 Storage and Operating 32 to 120°F(0 to 49°C) Temperature Onboard LED Operation Red LED-flashes when in alarm or test state Mounting North American electric box:2 inch deep 2-gang or 4 inch square;European electric box: 100 mm square Construction&Finish High Impact Engineered Plastic 2-gang front plate-White Addressing Restrictions Uses one Module Address EDWARDS SYSTEMS TECHNOLOGY Issue 4 Literature Sheet #85001-0325 Page 3 of 4 Not to be used for installation purposes. For the most current literature and updates visit www.est.net. A opiication Notes Sample tube length must span the entire width of the air duct and the tube can be easily cut to any length.Inlet tubes longer than 3 .e SIGA-DH Duct Smoke Detector Housing requires a clear,flat, ft.(900mm)must be supported at both ends. accessible area on the duct of at least 7-3/8 inches(188mm)W x 7 inches(175mm)H.The duct housing must be installed on ducts Duct detectors continually sample airflow in a HVAC duct and at least 8 inches(200rnm)wide.To avoid the effects of initiate an alarm condition whenever smoke is detected.An alarm stratification,install the detector housing a minimum of six duct is activated when the quantity(percent obscuration)of combustion widths beyond any bends in the duct.Duct detectors are usually products in that air sample exceeds the detector's sensitivity installed on the supply duct after the air filters;or in the return air setting. stream prior to being diluted by outside air. Air velocity in the duct maintains the air flow that enters the detector housing through perforations in the air sampling inlettube and discharges through the outlet exhausttube.The detector '_ housing must be installed with its INLET air sampling tube upstream of the EXHAUST tube.Before installing the duct detector Bend or other 'housing,test the duct air velocity to verify it is within the limits of obstruction the Signature smoke detector that is being installed.Also verify that duct air relative humidity is within 0%and 93%. ill WARNING:Duct detectors have specific limitations.Duct detectors ARE NOT a substitute for an open area smoke detector.Duct ■ detectors ARE NOT a substitute for early warning detection.Duct 'Duct detectors ARE NOT a replacement for a building's regular fire width detection system.Smoke detectors ARE NOT designed to detect . 6 Duct widths i Duct detector toxic gases which can build up to hazardous levels in some fires. (minimum) These devices WILL NOT operate without electrical power.As fires location frequently cause power interruptions,EST suggests you discuss further safeguards with your local fire protection specialist. Ordering information installation and Mounting •alog Ship Wt EST recommends duct detectors always be installed in nber Description lb.(kg) accordance with the latest recognized editions of local and SIGA-DH Duct Detector Housing 6.5(3) national fire alarm codes. 6261-001 8 inch(200mm)Air Sampling Inlet Tube .25(.1) 6261-002 24 inch(600mm)Air Sampling Inlet Tube .5(.2) Front Cover 0 t 6261-003 42 inch(1060mm)Air Sampling Inlet Tube 1.6(.8) .: : 4 4: ■ Adapter Plate 6261-006 78 inch(1980mm)Air Sampling Inlet Tube 2.2(1) 1 '. . r Base 6261-010 120 inch(3048mm)Air Sampling Inlet Tube 4.4(2) : L l SIGA-IPHS 4D Multisensor Detector Detector SIGA-PHS 3D Multisensor Detector .5(.23) SIGA-PS Photoelectric Detector SIGA-SB Standard Base Locating Pin fiL-_k SIGA-RB Relay Base � � Smoke chamber SIGA-IB Isolator Base 2('09) i Neoprene gasket SIGA-LED Alarm LED Indicator Exhaust tube ie connector SIGA-DTS Duct Test Station .4(.18) Air sampling 6263-SG Duct Air Velocity Test Kit Exhaust tube tube connector °,..-Air inlet ° sampling tube t-Rubber stopper I Airflow -.4 c‘ , EDWARDS SYSTEMS TECHNOLOGY It is our intention to keep the product information current and accurate.We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice.For more information or questions relative to this Specification Sheet contact EST. ©2003 EST Printed in U.S.A.(origin) Page 4 of 4 Literature Sheet #85001-0325 Issue 4 Not to be used for installation purposes. For the most current literature and updates visit www.est.net. w L. Security Intelligent Initiating Devices Overview Standard Features Signature Series Model SIGA-HFS and SIGA-HRS Intelligent Heat Note:Some features described here may not be supported by all Detectors gather analog information from their fixed temperature control systems.Check your control panel's Installation and Opera- and/or rate-of-rise heat sensing elements and converts it into dig- tion Guide for details. ital signals.The detector's on-board microprocessor measures and 70 foot(21.3 meter)spacing •analyzes these signals.It compares the information to historical readings and time patterns to make an alarm decision. Digital fil- • 15°F(9°CI/min rate-of-rise/135°F(57°CI ft.and 135°F(57°Cl ters remove signal patterns that are not typical of fires. Unwanted fixed temperature type alarms are virtually eliminated. Intelligent detector c/w integral microprocessor •The microprocessor in each detector provides four additional ben- • Non-volatile memory efits-Self-diagnostics and History Log,Automatic Device Mapping, Stand-alone Operation and Fast,Stable Communication. • Automatic device mapping • Electronic addressing • Identification of defective detectors • Twin RED/GREEN status LEDs • Standard,relay,fault isolator,and audible mounting bases • Designed and manufactured to ISO 9001 standards in c per.. e t Detect; rc SIGA-I-- FS & SIA-HRS . 00Thi‘[.. fl CO CE ® Apphcatton Notes g69,_ Available Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes.Page 1 of 6 Signature Series Overview Installation Spacing-The SIGA-HFS(fixed temperature)and the Self diagnostics and History Log Each Signature Series detec- SIGA-HRS(fixed temperature/rate-of-rise combination)intelligent tor constantly runs self-checks to provide important maintenance heat detectors are rated for installation at up to 70 foot(21.3 meter) spacing.These detectors may be installed in rooms with ambient rormation.The results of the self-check are automatically updated temperatures up to 100°F(38°C). and permanently stored in the detector's non-volatile memory. This information is accessible for review any time at the control panel, Status LEDs-Twin LEDs are visible from any direction.A flashing PC,or by using the SIGA-PRO Signature Program/Service Tool. GREEN LED shows normal system polling from the loop controller.A In the unlikely event that an unwanted alarm does take place,the flashing RED LED means the detector is in alarm state.Both LEDs on control panel's history file can be called up to help isolate the prob- steady shows alarm state-stand-alone mode.Normal GREEN LED activity is not distracting to building occupants,but can be quickly (em and prevent it from happening again. spotted by a maintenance technician. Automatic Device Mapping-The loop controller learns where Quality and Reliability-GE Security detectors are manufactured each device's serial number address is installed relative to other in North America to strict international ISO 9001 standards.All devices on the circuit.This mapping feature provides supervision electronics utilize surface mount technology(SMT)for smaller size of each device's installed location to prevent a detector from being and greater immunity to RF noise.A conformal coating is used for reinstalled(after cleaning etc.)in a different location from where it humidity and corrosion resistance.All critical contacts are gold was originally.The history log for the detector remains relevant and plated. intact regardless of its new location. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support,the wired circuits between each device can be examined.Layout or"as-built" drawing information showing wire branches(T-taps),device types Installation and their address are stored on disk for printing hard copy. This Signature Series detectors mount to North American 1-gang boxes, takes the mystery out of the installation.The preparation of as-built 3-1/2 inch or 4 inch octagon boxes,and to 4 inch square electrical drawings is fast and efficient. boxes 1-1/2 inches(38 mm)deep.They mount to European BESA Stand-alone Operation-A decentralized alarm decision by the and 1-gang boxes with 60.3 mm fixing centers. detector is guaranteed.On-board intelligence permits the detector J 0.8"(20 mm) to operate in stand-alone mode.If loop controller CPU communica- T tions fail for more than four seconds,all devices on that circuit go into stand-alone mode.The circuit acts like a conventional alarm 2.0"(51 mm) receiving circuit.Each detector on the circuit continues to collect -nd analyze information from its surroundings.Both the SIGA-HRS `=®®!/ d SIGA-HFS detectors alarm if the ambient temperature increases ��®�� to 135°F(57°C)or for the SIGA-HRS only,the temperature increases M H at a rate exceeding 15°F(9°C)/minute. If the detector is mounted 4.4"(>12 mm) to a relay base,the relay operates.Similarly,if it is mounted to an audible base,the on-board horn sounds. Fast Stable Communication-On-board intelligence means less Tamper-Resist Lever Arm I�I�I► information needs to be sent between the detector and the loop -Break off to disable- !1 ��k0 Ill ';?� controller.Other than regular supervisory polling response,the (Located on Base) detector only needs to communicate with the control panel when it has something new to report.This provides very fast control panel response time and allows a lower baud rate(speed)to be used for communication on the circuit.The lower baud rate offers several Access Slot Me for ti Tamper-Resist Mechanism advantages including: _ i valid - less sensitivity to circuit wire characteristics 1 ., - less sensitivity to noise glitches on the cable ceD " - less emitted noise from the data wiring r - twisted or shielded wiring is not required Electronic Addressing-The loop controller electronically addresses each detector,saving valuable time during system commissioning. Setting complicated switches or dials is not required.Each detector has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the circuit and assigns a"soft"address to that device's serial number.If desired,detectors can be addressed using the SIGA-PRO Signature Program/Service Tool. Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes.Page 2 of 6 Application The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors.The table indicates that no single sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA- HFS Rate-of-Rise/ SIGA-PHS .SIGA-IPHS Test Fire SIGA-IS Ion SIGA-PS Photo Fixed Temp. Photo Heat 3D lan/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases will accept#18 AWG(0.75mm2),#16(1.0mm2), #14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. Note:Sizes#16 AWG 11.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base,SIGA-SB,SIGA-SB4 Relay Detector Base,SIGA-RB,SIGA-RB4 Term Description Term Description Remote LED 1 Not Used Normally-Normally- 1 Normally-Open 0 en (SIGA-LED) 2 DATA IN/OUT(+1 Common Closed Open 2 DATA IN/OUT 1+1 Max.Resistance 3 Not Used 3 Common •ID per Wire 4 DATA IN(-1 4 DATA IN(-I _ + Must NOT Exceed 1052 4 Remote LED() 5 Not Used 5 Remote LED 1+1 6 Normally-Closed b 6 Not Used 6(C. 7 DATA OUT(-1 ril t,,y'� \ 7 DATA OUT(-I O C y,, /r \ f )_ Q'7 qt, CONTACT RATING J O . 1.0 Amp @ 30 VDC �t 1 ' IL r,, O (Pilot Dutyl DATA IN(-) 4;71 O DATA OUT(-) DATA IN(-) t z?I / DATA OUT(-)4. DATA IN(+) DATA OUT(+) DATA IN(+) DATA OUT(+) From Signature Controller To Next Device From Signature Controller To Next Device or Previous Device or Previous Device Isolator Detector Base,SIGA-IB,SIGA-IB4 Audible Detector Base,SIGA-AB4G ® o o Term Description 1 Not Used F Volume setting Tone setting 6 6 -= 2 DATA IN/OUT(+I /130,4 Default=High volume Default=Temporal pattern `Q' 0 4 DATA Used(-I Cut for low volume ® Cut for steady tone v'/,' ® 5 Not Used oo,1.OAT,o r Q O . 6 DATA OUT(-I 1 111 11 11 I I o ccs• . ` 7 Not Used hhLL.I� �`��= � I:i:r�cr .r .l To configure output volume I�_ +� -r� +� +��-�� or lone,cut the circud board DATA IN(-) \ Z O I"`0.4,,. 'I��I".1I as shown. DATA OUT() 111111 24 Vdc in _ From power supply or,. •:;i 24 Vdc out DATA OUT(+) previous base To next base or EOL relay DATA IN(+) To Next Device Data in From Signature Controller From Signature controller or Data out or Previous Device previous device ` To next Signature device Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes.Page 3 of 6 Accessories All detector mounting bases have wiring terminals that are acces- Isolator Base SIGA-IB,SIGA-lB1 -This base includes a built-in line --ible from the"room-side"after mounting the base to the electrical fault isolator for use on Class A circuits.A detector must be installed )x.The bases mount to North American 1-gang boxes and to 31/2 for it to operate.The isolator base does not support the SIGA-LED inch or 4 inch octagon boxes,11/2 inches(38 mm)deep.They also Remote LED. mount to European BESA and 1-gang boxes with 60.3 mm fixing The isolator operates as follows: centers.The SIGA-SB4,SIGA-RB4,and SIGA-IB4 mount to North American four inch square electrical boxes in addition to the above - a short on the line causes all isolators to open within 23 msec boxes.They include the SIGA-TS4 Trim Skirt which is used to cover - at 10 msec intervals,beginning on one side of the Class A the"mounting ears"on the base.The SIGA-AB4G mounts to a 4" circuit nearest the loop controller,the isolators close to sgare box only. provide the next isolator down the line with power - if the isolator next to the short closes,it reopens within 10 msec. The process repeats beginning on the other side of the loop control - . " ler. SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED Remote LED SIGA-LED-The remote LED connects to the SIGA-SB Audible Base Standard Base Isolator Base Relay Base Remote LED or SIGA-SB4 Standard Base only.It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. Standard Base SIGA-SB,SIGA-SB4-This is the basic mounting base SIGA-TS4 Trim Skirt Supplied with 4 inch bases,it can also be for GE Security Signature Series detectors.The SIGA-LED Remote ordered separately to use with the other bases to help hide surface LED is supported by the Standard Base. imperfections not covered by the smaller bases. Relay Base SIGA-RB,SIGA-RB4-This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp(pilot duty)@ 30 Vdc.The relay's Warn i ngs & Cautions position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to This detector will not operate without electrical power. As fires fre- do so at the control panel(EST3 V.2 only).The relay base does not quently cause power interruption,we suggest you discuss further support the SIGA-LED Remote LED. safeguards with your fire protection specialist. Audible Base SIGA-AB4G-This base is designed for use where This detector will NOT sense fires that start in areas where heat cannot localized or group alarm signaling is required.When the detector reach the detector.Heat from fires in walls,roofs,or on the opposite -nses an alarm condition,the audible base emits a local alarm side of closed doors may not reach the detector to alarm it. gnal.The optional SIGA-CRR Polarity Reversal Relay can be used The heat sensor in this device only provides a source of informa- for sounding to other audible bases on the same 24 Vdc circuit. tion to supplement the information provided by photoelectric or Relay and Audible Bases operate as follows: ionization smoke detectors which may be located nearby.The heat -at system power up or reset,the relay is de energized detector by itself does NOT provide life safety protection. Under no circumstances should heat detectors be relied on as the sole means -when a detector is installed in the base with the power on,the of fire protection. relay energizes for four seconds,then de-energizes -when a detector is removed from a base with the power on, the relay is de-energized Compatibility -when the detector enters the alarm state,the relay is energized. The SIGA-HFS and SIGA-HRS detectors are compatible only with GE Security's Signature Loop Controller. • Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes.Page 4 of 6 Specifications Catalog Number SIGA-HFS SIGA-HRS Heat Sensing Element Fixed Temperature Fixed&Temperature/Rate-of-Rise Alarm Point Alarms at 135°F(57°C)Ambient Alarms at 135°F 157°C)Ambient or Temp.increase above 15°F(9°C)per min. UL Listed Detector Spacing 70 feet(21.3 meters)center to center spacing Operating and Storage Environment Operating Temp:32°F to 100°F(0°C to 38°C)Storage Temp:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93%RH, Non-Condensing Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Operating Current Quiescent:45pA @ 19 V Alarm:45pA @ 19V Emergency Stand-alone-Alarm Mode:18m-A Pulse Current:100 pA (100 msec) Construction&Finish High Impact Engineering Polymer-White Compatible Mounting Bases SIGA-SB Standard Bose, SIGA-RB Relay Base,SIGA-IB Isolator Base, SIGA-AB4,SIGA-AB4G Audible Bases LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashes when in alarm Both LEDs-Glow steady when in alarm(stand-alone)Compatible Remote Red LED(model SIGA-LED)Flashes when in alarm • Compatibility Use With:SIGNATURE Loop Controller Address Requirements Uses one device address Agency Listings UL,ULC,MEA,CSFM Ordering information Catalog Number Description Ship Wt. lbs(kg) IMO SIGA-HFS Intelligent Fixed Temperature Heat Detector-U_UULC Listed 0.5(023) SIGA-HRS Intelligent Fixed Temperature/Rate-of-Rise Heat Detector-UUULC Listed Accessories SIGA-SB Detector Mounting Base SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS Trim Skirt SIGA-RB Detector Mounting Base w/Relay 0.2(.09) SIGA-RB4 4-inch Detector Mounting Base 1w Relay c/w SIGA-TS Trim Skirt SIGA-I13 Detector Mounting Base w/Fault Isolator SIGA-lB4 4-inch Detector Mounting Base w/Fault Isolator c/w SIGA-TS Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible(Sounder)Base 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1(.04) Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes.Page 5 of 6 O WIRING DIAGRAMS SPECIFICATIONS 0 - Standard Detector Base, SIGA-SB4 Operating Temperature Range 32 to 120°F(0 to 49°C) Operating Humidity Range 0 to 93%RH Storage Temperature Range -4 to 140°F(-20 to 60°C) Remote LED Construction&Finish High Impact Engineering Polymer, (SIGA-LED) Maximum White Resistance Compatible Detectors Signature Series Detectors per Wire •110 Must NOT Shipping Weight _ + IOI Exceed 1052 SIGA-SB4 2.9 oz(82 g) Max.Distance From Ceiling 12 in(305 mm) (for wall mounting) O ` t6 Related Parts 4 in Box Trim Skirt/Ring (SIGA-TS) li "'` r,..,.,%. ,V'' Compatible Electrical Boxes =MMk �-r O North American 1-Gang Box coo* � 3-1/2 in by 1-1/2 in(38 mm)Deep Octagon Box G_loi European 1-Gang(75 mm)Box w/60.3 mm Fixing Centers DATA IN (-) z I O DATA OUT(-) BESA Box 4 in by 1-1/2 in(38 mm)Deep Octagon Box lO� 4 in by 1-1/2 in(38 mm)Deep Square Box(using outer mounting brackets on base) DATA IN (+) DATA OUT(+) NOTES: From Signature Controller To Next Device 1) The SIGA-SB4 provides wiring terminals for connection to Remote or Previous Device LED,Model SIGA-LED. 2) These bases will accept 12,14,16,and 18 AWG(2.05 sq mm,1.5 sq mm, 1.0 sq mm, and 0.75 sq mm)wire. Sizes 16 and 18 are preferred. Term Description 3) Write the address assigned to the detector on the label provided 1 Not Used and apply the label to the inside rim of the base. 2 DATA IN/OUT(+) 3 Not Used 4) Break wire run at each terminal.Do not loop signaling circuit field 4 DATA IN(-) wires around terminals. 4 Remote LED 5 Remote LED 6 Not Used SIGA-SB4 7 DATA OUT(-) iT1t1IIIIIII/• INSTALLATION SHEET SIGA-SB4 Detector Base INSTALLATION SHEET P/N:387034P FILE NAME:387034P.CDR DATE:01/18/99 REVISION LEVEL:7.0 APPROVED BY:B.Right CREATED BY:C.Hanrahan 7 9 3 0 1 6 0 1 9 8 0 6 GS BUILDING SYSTEMS CORPORATION 6411 Parkland Drive 625 6th Street East GS BUILDING SYSTEMS Sarasota,FL 34243 Owen Sound,Ontario CORPORATION USA Canada N4K 5P8 O GENERAL WIRING PRACTICES Refer to 'mpatible panel Standard Detector Base Relay Detector Base Isolator Detector Base tallation sheet for terminal assignments. JD 101 O rT O , 6 ? . 0 6=r 0 ,-_ii., O �ih �r X11 a� 11 e 7-, ' � '� 1/,� , 7 Imo'` V... . 0 s r]- SR�j `" Q7 1, °`\ tR �' ,-_ lam \ ,.,CS, _ O lol n lol t " wl lol 1 E. ® Insulate Shield/Drain � L t. + ® with tape Shield/Drain J / S [] Shim,.,d — Control Panel 1. Shielded wire is required ONLY in environments with very high electrical noise. AShields must be continuous and insulated from ground. AFor Class B wiring,there is no shield connection to ground at the last device. KO MOUNTING DIAGRAMS by 1-1/2" (38 mm) Deep Square Box(Surface Mount) 4"Box Trim Skirt/Ring r OO O 1.5"(38 mm) m. 0.8"(20 mm)1 12.0"(51 mm) s O Wes®®/i 11111kimmino011,' N N 4.4"(112 mm) SIGH-TS 4" by 1-1/2" (38 mm)Deep Square Box(Flush Mount) Flush Mount Electrical Box NOTES: 1) A 4" Box Trim Skirt/Ring (SIGA-TS) must be installed to give a r "finished"appearance to the 4"base. alillO O O 1.5"(38 mm) 2) Refer to Installation Sheet P/N 387056P for additional information. 0.8"(20 mm) 2.0"(51 mm) k H 4.4"(112 mm) P/N:387034P REV:7.0 Page 2 of 4 Quick EDWARDS SYSTEMS TECHNOLOGY CONTROL PANELS Corstpatibility-, Quickstert CIS1 Intelligent single loop ° ' ma6aQaz;` life safety control pane l 1M rofi a . - f CE Features - -- r E Supports up to 250 Signature Series intelligent devices !� ✓ Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable suppression ✓ Failsafe mode ensures uncompromised reliability • Class A(Style 7)or Class B(Style 4)wiring options • Capacity for eight serial annunciators GotliCit • Four built-in system relays • Optional dual line dialer supports Contact ID and 4/2 formats • Three methods of programming:QuickStart QS1's setup routine is deceptively simple,considering this `buto-learn,"front panel and personal computer(PC) system's robustfeatures.Supporting up to 250 intelligent detectors ■ Supports optional barcode scanner for direct device data entry and modules,QS4 takes full advantage of EST's exclusive Signa- ture Series technology,which provides electronic addressing, ✓ Optional bank of 30 front panel switches with dual LEDs automatic device mapping,environmental compensation,and true multisensor detection. L 20 adjustable pre-alarm settingsfor Signature smoke detectors QuickStart's innovative design makes it easy to add a dialer or • Wallboxes available in red or gray with optional trim ring for extra auxiliary relays.Quick-Lok option cards snap onto QS1's semi-flush mounting. easily-accessible DIN mounting rails.QS1 also supports as many I Large 14-line(224 character)backlit LCD display as eight remote annunciators and up to 30 programmable front panel switches with dual LEDs for system control and display. • Four password levels,plus priority access keyswitch QS1 is as simple to operate as it is to set up.Its large 14-line backlit ■ Message routing by event type or by individual message LCD display provides easy-to-understand details concerning up to • Alarm sensitivity by time of day or manual selection 1,000 system events,while bright system status LEDs and large, tactile control buttons present the user with a clean,crystal clear • 1,000 event history buffer,plus alarm history counter interface.Four password levels limit control and information • 6 amp Power Supply,4.75 amps available for external use retrieval to authorized personnel.A priority access keyswitch gives Level 2 access without a password to management and emer- gency personnel. Description EST's QS1 life safety control panel brings big-system intelligent Application control to small applications.Designed for easy setup and simple Thanks to its flexibility and simple setup and operation,QS1 is installation,QuickStart lives up to its name in every respect.QS1's ideal for new installations in schools,apartment buildings,hospi- exclusive QuickStart auto-learn function,and the option of tals,office buildings,and retail facilities. configuring the panel using convenientfront panel programming or from a PC,makes short work of system setup.Devices come on- The benefits brought by QS1 to retrofit applications underscores line in no timeas well,thanks to QS1's built-in barcode scanner the true potential of this powerful system.As an intelligent panel, port.A simple pass of the optional scanner is all it takes to store QS1 supports Signature Series devices,which can use existing device information in the QuickStart database.The scanner can wiring in most retrofit applications.This makes upgrading from a also be used for quick and easy text entry when assembling conventional system to analog control a simple operation with custom messages. minimal disruption to normal operations atthe site. EDWARDS SYSTEMS TECHNOLOGY, INC. U.S.SALES:SARASOTA,FL 941-739-4200;FAX 941-727-0740 • CANADA SALES:OWEN SOUND,ON 519-376-2430;FAX 519-376-7258 INTERNATIONAL SALES:905-270-1711;FAX905-270-9553 • CORPORATE HEADQUARTERS:CHESHIRE,CT • U.S.MANUFACTURING:PITTSFIELD,ME Issue 1 Literature Sheet #85005-0113 Page 1 of 6 Not to be used for installation purposes. 7B 1a I®n ©e000e00 +a+a+s m©+e Indicators Controls 1 1. Text display and .- 13.Reset button: ate °t ft` controls:Displays 3 _ 11 Allows devices or - ;r �� °gip system messages, ) 1 "`° , , 1 zones in alarm or ''' .%/- v,�'aa status information, : ''~ '� ---'-- "a_.. , and programming J _ _ Ix-� theirst to restore to theirstandb Y j mod? s q/_/4.4-1/ ile menus.Arrow condition.The LED buttons move the ,o +> ,2 indicates thatthe ,am® display cursor. panel is resetting. 2. Alarm LED:Indicates a fire or life threatening emergency. 14. Alarm Silence button:Turns active notification appliances off 3. Supervisory LED:Indicates an off-normal condition with the depending on panel programming.Pressing Alarm Silence a fire suppression system or related equipment. second time turns them back on.The LED indicates thatthe panel is in alarm and operating with notification appliances 4. Disable/Test LED:Indicates part of the system is disabled or turned off. being tested.Disabled components also signal a system trouble. 15. Drill button:Activates notification appliances depending on panel programming but does not place the panel in alarm. 5. Monitor LED:Indicates the operation of an ancillary system The LED indicates that the panel is in Drill Mode. function(door closures,fan pressure switches). 16. Menu button:Displays the operator menus. 6. Trouble LED:Indicates an off-normal condition or wiring fault 17. Delete button:Returns to the previous menu or backspaces that compromises the integrity of the system. the cursor. 7. Ground Fault LED:Indicates a ground fault in the system wiring.Ground faults also signal a system trouble. 18. Enter button:Press the Enter button to accept information or continue to the next item. 8. CPU Fail LED:Indicates an unexpected reboot or failure with 19. Numeric keypad:Numbered buttonsfor entering values and the microprocessor.CPU failures also signal a system trouble. making menu selections. 9. Power LED:Indicates the panel has power. 20. Barcode scanner jack:lnputfor optional barcode scanner. Help button:Provides additional information about the device 21. Priority Accesskeyswitch:Enables control functions reserved selected on the display. for access level 2 and above without requiring a password. 11.Status button:Displays the Status Menu from which you can identify active or disabled points in the system. 12.Panel Silence/Acknowledge button and LED:Acknowledges all events posted in the display queues and turns off the panel buzzer.The panel silenced LED indicates that off normal events have been acknowledged. CPU / LCD Display The QS1 front panel display Specifications p p y provides 14 lines by 16 characters of text detailing event,device,diagnostic,and programming Operating Temperature:32-120°F(0-49°C) information.Its large backlit LCD screen is easy to read and always environment Humidity: 93%RH,non-condensing provides at-a-glance indication of the system's state of operation. Current Standby: 117 mA when connected to PS6; requirements 105 mA when connected as a The CPU/Display Unit houses the CPU card and mounting space for remote annunciator one optional LED/Switch card. Alarm: 135 mA when connected to PS6; 123 mA when connected as a , remote annunciator Pe 2? se . ,.. ` In.. ROB Q0OD R oat ,t ee artu s Pal t et IT tt tt ar D. SPOKE ROOM 3'Y! FailsafeMode COO•Jft7LRfl3=4 aMop P•or r o: o•z+ev If the CPU loses communication with other circuit cards,the power SPPIPPLOP POOP ;R7 7 _ lto supply card continues to monitor the system for any alarm events. Ft; SLOP TOOL 1131, j P If an alarm occurs on any device or circuit during a communica- r33 r a 0190 r 3c tions failure,the power supply activates all alarm outputs and r;� instructs the dialer to transmit a default alarm message tothe 1 '1 monitoring station. •with two alarms shown a+.,tsea EDWARDS SYSTEMS TECHNOLOGY, INC. Page 2 of 6 Literature Sheet #85005-0113 Issue 1 Not to be used for installation purposes. Typical Wiring Class A Signature Data Circuit ---I LEGEND 1 RM 1 Pr Class A Notification k Integrity O Junction ! ! Appliance Circuit with Horn-Strobe Box I j.._ 2 A A A A Genesis Signals and j 0 UM A Nr I ' \/ , ' l \/ Signal Masterfor Genesis s End-of-Line ! y I P. I o w a A �/ A Gil A _ Independent Horn and Horn-Strobe S Resistor iii P B c, G, ' O^ ' Strobe Control and Synchronization over e ! -"—"—"— CR twocbnductors. Genesis n Programmable ! I Signal Master I/O Module j ! j .._..___.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.i O Smoke I-7 Universal I ! Detector I/O Module ! I I i S k Detector u Circuit jclass A Fire -••_.._.._.._.._.._.._.._.._.._.._..—.._.._.._.._, ! 2-Wire oe IDnpult Module ! : Signature Data Damper ! ! Circuit i ! Smoke Detector icrzl Control Relay 2 ' ' 2 ' 2 - 2 ©with Relay Base Module 1 - �� 2nd Floor I ©Smoke Detector Signal (� �+ �\/ \/ w �w gyp/ with Isolator Base Module 1 ! Y Class B Notification CC1 V-\ 0 /-\ o X ; u ; �r►� ; /-\_ g "` Appliance Circuit © Manual ® Signal Module CC1S \ 2Pr Pull Station (synchronization) j I �. 1 1 C..._.._.._.._.._.._.._.._.._.._.._.._.._.._.! .._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._._.._.._.._.._ More_ I ore wiring suggestions can be found o"-. 2 10 -"-" 2 ' ' 2 ' ' fl a'--'F "-'- 2 "-"-' 2 "-• •_. ', ! in the QS 1 Fire Alarm Control Panel ! i I ! ! — ! ! Installation, I I Operation,and Mainte- ..,. jr"` ro Critical Process ! ! Watertlow — Hance Manual,P/N 3100184.1 ; Monitoring — r— i �swibn j I with Control F--CT2 '-SSpurinekrveo Switch I CR Dimensions i. is ' 'V \/ ' 'V \/ Elevator I I ��rz<%mj 1 1 1 I �� I r x- Capture 1 CR I °o 8 Class A Notification l Appliance Circuit QS1 Panel Pi - P15]2cml Class B Signature Data Circuit ° - RM T P Horn and Strobe Synchronization with Audible Silence Class B Notification : —1CC1�- z P Appliance Circuit with o \/ \� \/ \/ Genesis Signals and c g Oj � CC1S J M 0 0 � 0 SiIndenal pendent Master Horn for and Strobe Control and j Synchronization over q- i two conductors. Mounting — 2.2" Signature j (5.6 cm) Data Circuit(1 pr.) Fire :..---- 2 - _ 2.68"—� 12.4cm Damper �'—•�'_.a—'_O._'� 2nd Floor 6.8 cm ( ) \/ \/ \/ \/ . CC1 0 /-( /0 4 0 0 a I 0 Y Horn and Strobe '0 Control(2 pr) c i s zPr 01 j . C=4-24 P^z Critical Process— Waterflow ! 1 ! _4 Monitoring Switch ! • Wall i Wall I F '-°-" CT2 Sprinkler . i Supervisory P P Switch CR Semi-flush Surface a.. \/ \/ \/ I Elevator Mounting* Mounting 0 A $-*-0—A--0—x$-A 0 Capture i JJJ���� U I i Semi-flush mounting requires an Notification Appliance Circuit: CR optional trim ring,which adds 3/4'to Horn and Strobe Synchronization with Audible Silence all sides of the panel. QS1 Panel EDWARDS SYSTEMS TECHNOLOGY, INC. Issue 1 Literature Sheet #85005-0113 Page 3 of 6 Not to be used for installation purposes. ._., :andard Components and Option Cards i - -w°; I4)' uS1 panels come standard with a CPU/Display Unit,an SLIC Signature Loop Controller, ;t mN and a PS6 Power Supply(see ordering information for details). I } f t sF; 'r !4 Available QS1 option cards provide dialing capability or extra relays for anciliary , control.Quick-Lok option cards snap onto DIN mounting rails fast,no-fuss installation. • � , I One option card space is available. ,. le Cabinet with option card " - ..�. ,. ,_s and batteries installed. STANDARD COMPONENT Power Supply Card PS6 The PS6 provides primary dc power to all the .1131 mismomespon Specifications circuit cards installed in the cabinet.There are 444e411L4 AC input: 115 or 230 Vac,50/60 Hertz !° Main supply circuit DC input:four 24 Vdcpoweroutputcircuits—three for `t ppY c°,, , p t: 24 Vdc batteries powering auxiliary applications,and one for r Battery charging circuit Charge current:2 amps powering four-wire smoke detectors—and a 111 '01 Charge capacity:40 amp hours(UL) charging circuitfor standby batteries.The PS6 I a 30 amp hours(ULC) also provides common alarm,supervisory,and i,; trouble relays,as well as a fourth relay that is In 't Smoke/Accessory Voltage:24 Vdc,regulated s y y TB2 7;ENS,X441SX power output circuit Current: 250 mA user programmable. _ Wire size: 12 to 18(0.75 to 2.5 mm2) Auxiliary power Quantity:3 Wiring w„,016 TB2 I®I®I®I M®014®0® output circuits Voltage:24 vdc full wave rectified 6”° I � R I I I Current: 1.5 amps each © °-° 100000000000000000 of Tim ° Common alarm relay Style: Form C RAY, PEW,RELAY,NUM, ■ a��M Contact rating: 1 amp AGO MR R52.32 Wire size: 12 to 18 AWG(0.75 to 2,5 mm2) 1: Form C.Contacts change position when the control panel processes an alarm Trouble,Supervisory Style: Form A signal and remain changed until all active alarm inputs restore and the control panel and programmable Contact rating: 1 amp resets. Relay2: Form A.Contacts change position when the panel processes a supervisory signal relays Wire size: 12 to 18 AWG(0.75 to 2.5 mm2) and remains changed until all active supervisory inputs restore. Operating environment Temperature:32-120°F(0-49°C) Relay3: Form A.Contacts change position when the panel loses power or processes a Humidity:93%RH,non-condensing trouble signal and remains changed until power returns or the trouble clears. Relay4: Form A.Relay closes and opens accordingto panel programming. Current requirements Standby current:72 mA Smoke/Accessory Power:Jumper setting determines ifthe 24 Vdc is constant or resettable. Alarm current:96 mA. STANDARD COMPONENT Signature Loop Intelligent Controller SLIC The SLIC provides one Class A or Class B data __ Specifications circuit(loop)for connecting Signature Series ,rBt Signaling line Configuration:Class B(Style 4)or Class A(Style 7) detectors and modules.The SLIC also provides ,' circuit Capacity: 125 Signature detectors two programmable Class A or Class B notifica- 125 Signature modules tion appliance circuits(NACs)for connecting - Wire size: 12 to 18 AWG(0.75 to 2.5 mm2) polarized 24 Vdc notification appliances such Circuit resistance:65 ohms p pp ''°"' Circuit capacitance:0.3 f as horns and strobes.QS1 supports one SLIC. -_ p N �qw Notification Configuration:Class B or Class A . appliance Output voltage:24 Vdc,nominal .*?f' circuits#1 Output current: 2.0 A at 24 Vdc for#1 Wiring OUT IN LOOP ,.C rid and#2 and 1.0 A at 24 Vdc for#2 Class Class A — A+ A—e+ a_ .�,^ r Wire size: 18 to 12 AWG(0.75 to 2.5 mm2) eai"r— ie°�; ,- + - + r- End of line resistor: 10k ohms,'h W 00000000 T62 TB2 NAC power Voltage:24 Vdc,nominal } ® ,�_ , .. input circuit Wire size: 18 to 12 AWG(0.75 to 2.5 mm2) ".. Operating Temperature:32-120°F(0-49°C) O environment Humidity:93%RH,non-condensing Signaling Line Circuit tY 9 IMP and NACs are 0000000® Tit ,m� supervised and Current Standby current:33 mA -- _ requirements Alarm current:57 mA(Both NACs on) 6+ g—A+A—e+ 6—Al A— power-limited. 71 NAC2 Gass A Card spaces Requires one card space. EDWARDS SYSTEMS TECHNOLOGY, INC. Page 4 of 6 Literature Sheet #85005-0113 Issue 1 Not to be used for installation purposes. t OPTION CARD Dialer DAD The DLD is a ULI/ULC listed dual line Digital Alarm Specifications Communicating Transmitter(DACT).Itprovidestwo ,,, ., phone lineconnectionsforsending system messages 1131 Operating Temperature:32°F(0°C)-120°F(49°C) environment Humidity: 93%RH,non-condensing to a compatible Digital Alarm Communicator Receiver. 1' _ The DLD supports 4/2 and Contact ID formats.It Current Standby: 13 mA occupies one card space on the chassis rail. „; requirements Dialing: 26 mA SURGE Phone Lines Two loop start lines on switched telephone Pilo 1 OR RING Wiring ' RED) f �X" 4 network.Pulse or DTMF dialing. Wall Connector RJ31X/CA31A equiv.or RJ38X/CA38A equiv. RA1X (GREEN) 00510 5105 4 Communications Contact ID(SIA DC-05),4/2(SIA DC-02 P3). B PIN MODULAR a PHONE SAME#1) CONNECTOR FOR /P-H-O�NE UNE#11 i, Protocol PHONE LINE R7 f, GREEN / , \ �' aPIN MODULAR " Programming Via QuickStart,Front Panel or PC. - RED- , PHONE LWE pZ --, Communications Communications Canada CS-03FCC/CFR 47 Parts .' PREMISES W f t Compliance 15 and 68,NFPA 72,ULI 864,ULC S527-M87 NOT-TAPS Receivers Signals can be transmitted to either or both of two PERMRTED Nava �a� receivers. 0 0 0 0 0 0 0 0 TB? Telephone#s Two 24-digit numbers per receiver. TIP RNG TIP RNG TIP RNG TIP MG Card spaces Requires one card space. IN OUT IN OUT LINE1 LINE 2 OPTION CARD Relay Card ZR8 The ZR8 provides eight dry-contact relays Specifications that can be independently configured as mum T81 Output relays Style: Form A or Form B (jumper configurable) Form A or Form B relays.It occupies one Contact rating: 1 amp @ 30 Vdc resistive. card space on the chassis rail. L. Wire size: 18 to 12 AWG(0.75 to 2,5 mm2) PL PL Operating Temperature:32-120°F(0-49°C) A iring ` � 'NFL " D environment Humidity:93%RH,non-condensing +R5- +R6- +RT- +R8- A / \ Current Standby current:7 mA 10 0 0 0 0 000 Tsz PL requirements Alarm current: 18 ma per active relay V v A A A PL Card spaces Requires one card space. Y NFL / NPi 000000001-B1 TB2 NPL +R1- +R2- +R3- +R4- _ ...T.( : OPTION CARD Class A RS-485 Card and UART Port X485 The NT-A,which includes the X485/ Wiring RS-485 card and QS-232/UART Specifications port,provides one Class A serial 12 to 18 AWG(0.75 to 2.5 mm2) remote annunciatorbusforcon- `RA OA Wire size twisted pair(6 twists er foot minimum) RA RA P P necting remote annunciator panels. CHI CH1 Circuit resistance 100 Ohms Control panels require the X485 Circuit capacitance 0.4 pF card and UART port,which also Temperature:32-120°F(0-49°C) serves as a laptop or printer port. '. Operating environment Humidity:93%RH,noncondensing The X485 occupies one card space ,, on the chassis rail.The 0000�1 '_�< 7B1 Current requirements Standby:75 mA UART port plugs into cHZ ;it Alarm:75 mA the panel CPU. t' Card Spaces Requires one space for the NT-A %b 1 I II _ L .� . ms/J EDWARDS SYSTEMS TECHNOLOGY, INC. issue 1 Literature Sheet #85005-0113 Page 5 of 6 Not to be used for installation purposes. OPTION CARD 'Cl Switch Card SL30,SL30-1 The SL30 provides thirty switches with two associated Specifications LEDs per switch.These switches and associated LEDs Operating Temperature:32°F(0°C)to 120°F(49°C) can be used for point or zone annunciation of alarm, --_,u E s environment Humidity: 93%RH,non-condensing supervisory,monitor,and trouble signals.Buttons on "'",'" "`'` Current Standby: 1mA the SL30 are numbered 1 through 30. `"`"""` 9 requirements Alarm: 0.75 mA per active LED Remote Annunciators Ordering Information QS1 supports upto eight remote Part Number Description Ship Wt. annunciators,which provide __ °°, lb.(kg.) mirrored or customized annun- Basic Package-Enclosure,SLIC,Power Supply,CPU and Display ciation of front panel messages QS1-1-G-1 Single Loop System.One option card space. 17.0 and status indicators.Remote Gray enclosure with 115v transformer. (7.71) annunciators connect directly to " } QS1-1-R-1 Single Loop System.One option card space, 17.0 the PS6 Power Supply Card or Red enclosure with 115v transformer. (7.71) an external 24 Vdc filtered --` Note:SLIC Card includes One Signature Loop Intelligent Controller supply.They are available with for up to 250 devices and one Class A or two Class B NACs. wallboxesforflush or surface Enclosure Accessories mounting. TRIM-1 Trim Kit-gray,1 option card encolsure 5.0(2.27) Remoteannunciator(ClassBwiring) TRIM-1R Trim Kit-red,1 option card encolsure 5.0(2.27) Other Option Cards IZEIIIM f F A DLD Dual Line Dialer.Supports 4/2 and Contact ID 1.0 formats. (0.45) ZR8 Relay Card.8 programmable Form A contacts. 1.0(0.45) N ` 11 Display Options SL30 Annunciator module.Numbered 1 to 30. 1.0 III Two LEDs and one switch per zone. (0.45) Rat QS1-CPU-1 Single Loop CPU/Display,one annunciator 4.0 option space (1.81) ° ° ° NT-A RS-485 option card.Required for Class A 1.0 remote annunciation.Includes UART card. (0.45) Remote Annunciator Dimensions 05-232 UART option card.Plugs into CPU. Required for PC Programming/printer port. 1'0 Model Height Width Depth Included in NT-A package (0.45) QSA-1-S 7.6"(11.68 cm) 14.25"(36.20 cm) 2.9"(7.3 cm) Part Number Description Ship Wt. lb.(kg.) QSA-1-F(rough in) 6.56"(16.66 cm) 13.25"(33.66 cm) 2.1"(5.33 cm) Remote Annunciator Cabinets QSA-1-F(finished) 7.8"(19.81 cm) 14.42"(36.63 cm) 1.38"(3.49 cm) (c/w Interface Assembly;Require CPU/Display) Rough-in dimensions reflect the size of the cabinet where it enters the wall QSA-1-S Surface Remote Annunciator Cabinet. Finished dimensions reflect the size of the cabinet that protrudes from the wall. Space for one SL30 display card. 4.0(1.81) QSA-1-F Flush Remote Annunciator Cabinet. Space for one SL30 display card. 4.0(1.81) Programming Tools Which Quickstart Panel is right for you? QSC QS1 QS4 QS-CU QuickStart Panel Configuration Utility. 1.0(0.45) Signature Series devices supported 0 1 x 250 4 x 250 QS-Scan QuickStart scanner and programming guide. 2.0(0.91) Conventional Class B circuits supported 3 x 16 0 3 x 16 Accessories Conventional Class A circuits supported 5 x 8 0 5 x 8 PT-1S SystemPrinter-Desk top Style 14.0(6.35) LCD display(lines x characters) 4 x 20 14 x 16 14 x 16 BC-1(R) Battery Cabinet.Room for one 40 Ah 22.0 Optional Zone Switch/LEDs on front panel 2 x 30 1 x 30 2 x 30 or two 24 Ah batteries. (9.98) MFC-A MultiFunction Cabinet. 7.0(3.1) Option card spaces 5 or 12 1 5 or 12 IOP3A RS-232 Isolator Module. For more information,see 85005 This 85005 3.0(1.36) catalog sheet number... -0112 Sheet -0114 RPM Reverse Polarity Module. 3.0(1.36) 2-CTM City Tie Module. 1.0(0.45) API-8/232ME Alphanumeric Pager Interface. 11.0(5.0) BPS6 6.5 Amp Booster Power Supply 13.0(5.9) BPS10 10 Amp Booster Power Supply 13.0(5.9) CDR3 PSNI Coder Module 1.0(0.45) EDWARDS SYSTEMS TECHNOLOGY, INC. It is our intention to keep the product information current and accurate.We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice.For more information or questions relative to this Specification Sheet,contact EST. ©2001 EST Printed in U.S.A. Page 6 of 6 Literature Sheet #85005-0113 Issue 1 Not to be used for installation purposes. ........ ES7 - 12 IIIIIIIIMbr' SP ECIFICAIMS Maintenance-Free Rechargeable Sealed Lead-Acid Battery Nominal Voltage(V) lZV ��_ Nominal Copao�/ ~�� � -- ' 20bou m�(036A0o1�5OV) 7.2Ah 10hou ��(K72Amu1O.5OV) 7.2Ah 5huur��(1.22A|o1U.20V) 6.l2Ah =r'�|o�rw«&�n| --�^� 1C(7.2Ato9.60V) 3.24Ah 3C(21.6A0n9.60V) 2.59Ah 1,..... . 4.Ny iijillik - fanl�r--� Weight 5.9lLbs. (Z.h78kg) ' --= •, ��-4` Internal Resistance(at 1KHz) 18mD �� Z-°-`..~ ^.`. —`~~n�� Maximum D�oha�eCunan hx '`~` 3O seconds: 144A Maximum Discharge Current for DIMENSIONS 5 seconds: 280A Operating Temperature Range � Charge 0°C(32°F)to 40°C (104°F) IIIII—I'';' � mm(mvx) �� Discharge '15^C(5^F)to 50°C (122°F) Storage ga -15°C(5°F) (104°F) 6.35 � ~� -harge Retention(she life)at 20°C(68°F) Fl ED I month 92% ���T�mu,«n 3 month 90% ' 65±1 6mon� 80% 1(71 -7-w�� 151±1(5941.864) Charging Mo�nds��25^C�7^R ' `_ - Cycle use: Charging Voltage 14.4 to 15.0V e; ,=, ES7-16121172A1)101E) Maximum Charging Curren 2.16A • ,. s � �c��� � � � `�� �� S�ndbyuse: Float Charging Vo|�gel3.50tol3.80V - ~ No current limit required -- USIFV16.019:1910lEv . Life expectancy: Cycle Use� 100%depth of discharge 250 cycles :�; m""��"nm°VS.Discharge Current(25°C) 80Y6 depth of discharge 350 cycles -- 50%depth of discharge 550 cycles `� '� Standby J-5m '� 0 years i Case Material ABS = 1\ | | i ^~ ^~ �4 HB&84V�fbmer�arbntcase ° -- �N�� Terminal Fl � / / | | . | ����� III ' ` ^ ' `� ° ~ ° ` ` ^ '° ° /_- ~_~ _- __ �� _ • Discharge Time MK Battery 1045 South Sinclair Street Anaheim,California 92806 Toll Free:8OO'37Z'82B'Fax:714'837'0818`E-Mail:sales@mkbattery.com iftlill , Es12 - 12 Maintenance-Free Rechargeable Sealed Lead-Acid Battery Nominal Voltage(V) 12V Nominal Capacity 20hour rate(0.6A to 10.50V) 12Ah I--- 10hour rate(1.2A to 10.50V) 12Ah .. --„ � 5hour rate(2.04A to 10.20V) 10.2Ah EvivizA, . 1C(12A to 9.60V) 5.4Ah . .. l 3C(36A to 9.60V) 4.32Ah !"y�.._ a .�� jilt, Weight 9.39 Lbs. (4.27 kg) ," , Internal Resistance(at 1KHz) 13 ms2 Maximum Discharge Current for 30 seconds: 240A Maximum Discharge Current for DIDENSIONS 5 seconds: 480A Operating Temperature Range Charge 0°C(32°F)to 40°C (104°F) mm(inch)j—it> Discharge -15°C(5°F)to 50°C (122°F) 3.4 Storage 15°C(5°F)to 40°C (104°F) 7.95 ..7 m i7.1 D. ;barge Retention(shelf life)at 20°C(68°F) F2 1 month 92% (FASTON TAB NO.250) 92% e 3 month 90% [ 6 month 80% 99±1(3.9±0.04) > < 101±1(5.9430.04) Charging Methods at 25°C(77°F) r\ r, A — r, Cycle use: Charging Voltage 14.4 to 15.0V c Ft12-1411 Y1L„PBN , a =Maximum Charging Current 3.6A Standby use: Float Charging Voltage 13.50 to 13.80V F. ' :, w_.._. .-'..7: .7.,. ,,,M,n,„,,n,. No current limit required _,.... Life expectancy ,onv Discharge Time VS.Discharge Current(25°C) Cycle Use: 100% depth of discharge 250 cycles -- 7- 0�_ - 80% depth of discharge 350 cycles ,zo 50% depth of discharge 550 cycles -----~ I \ \ 1 Standby Use : 3-5 years }1 .a . .,` ,ha-aa-,4A ;�' Case Material ABS s` 9 (94-HB & 94V-0 flame retardant case) I a c n 10 ac au sc : a s a io Terminal F2 I._ m.n.,,, ho,,�= -.i Discharge Time MK Battery 1645 South Sinclair Street•Anaheim, California 92806 Toll Free:800-372-9253•Fax:714-937-0818•E-Mail:sales @mkbattery.com r o 1 1 ARE PRODUCTS AD! EVAX Systems EVAX Systems EVAX Systems II Voice Evac Panel Voice Evac Panel "t"" Voice Evac Panel EV-EVAX25 EV-EVAX100 EV-EVAX150 EV-EVAX50 v EV-EVAX200 • Includes • All the features of our ! • Expanded capacity *Mic "Amplifier 25 and 5e buttems, up to 2 zone mic DMR *Power Supply same size but and 16 zone switches *Battery Charger MORE POWER! • i in one cabinet all this in a single unit • NOW 100W AUDIO! • Total system capacity: • 4 to 8 zones optional 2000WI • 25 or 50Vimp • Single circuit MEAA u� P W MIEA uQ( ! 4'�� Safety Technology Safety Technology Fire-Lite Alarms Polycarbonate Enclosures NEMA 4X Battery Charger SF-7550 Polycarbonate Cabinet FL-CHG75 • 19.5"x 24.8"x 7.3" F ""' (.- SF-7520 SF-7530 'I • Rated for batteries • 12"x 14"x 6.37" 4 • Cl of 25 to 75 Ah 'fie Clear polycarbonate cover • Multi-purpose cover for ' • Includes key lock • 120VAC or 220/240 VAC operation arm large electronic devices • Mounts in a FL-BB26,FL-BB55F,FL-MS9600, g (model al opening nor thumb lock) • FL-MS9200,FL-MS92000D or FL-MS521OUD enclosure • Includes key lock • Additional opening where secondary pad lock t'f'4 • Two rotary action latches • or safety seal can be used • Screw terminal connections for battery, with additional eyelets • Lifetime guarantee against breakage battery backup to other equipment and SLC loop rim for secondary lock of polycarbonate cover • Connection to monitor charger • SF-7550-UL Listed,NEMA 4X R am 0 :--J cL ®FtreureAIarms by Honeywell ce Altronix Altronix National Training Center, Inc. NAC Power Extenders NAC Power Extenders Advanced NICET AX-AL1002ADA AX-AL1042ADA Testing & Study Guide NrcFRmorraX R • 24VDC @ 10 amp • 24VDC @ 10 amp I`' 5T-NICET3AN4 A01'" '"r`"�e.Ralr AX-AL802ULAD AX-AL842ULAD L • 12 or 24VDC @ 8 amp DC or 12VDC @ 8 amp Includes advanced concepts } �• AX-AL602ULAD AX-AL642ULAD required for NICET • 12 or 24VDC @ 6.5 amp : 27.w41/ 24VDC or 12VDC @ 6.5 amp • Updated to most current codes : C, o 1 amp aux outputs FM Q • Sample test questions included • 2 Class A/4 Class B outputs • Requirements for senior project , r• • 1 amp auxiliary output ME'A Q(.6 • Two(2)wire horn/strobe Sync mode • Easy to use and understand • Gentex,System Sensor,Faraday, • 4 Class A/4 Class B outputs Amseco Sync protocols IS • Gentex,System Sensor,Faraday, m; Altronix Amseco Sync protocols 2iAltronix l [ 5t Mt GE Security NEW! Silent Knight 24VDC Remote Booster Power Supplies 9-Amp Distributed Power Module "I ED-BPS6A S16499 MIMI • 6.5 amp,24VDC power booster I ED-BPS1 OA • UL Listed for 9 amps • 10 amp,24VDC power booster of notification power CI • Extends power available to Notification Appliance Circuits(NACs) • Power supply§ • Provides strobe synchronization for GE appliances advanced switch mode design • Configurable signal rates reduces damaging heat and manages power Zd• Field selectable input-to-output correlations up to 509fiore efficiently than other systems • Available in 10 and 6.5 amp versions • Dip switches allow for easy configuration • 24 VDC filtered output voltages smrMEA U ®FM C O 0 01 GE secumi 1 IMZ Fire-Lite Alarms Bosch Silent Knight Remote Power Supply/Sync 6A Remote Power Supply 6-Amp Distributed Power Module FL-FCPS24FS6 DS-DS9484 Sl5495 'g FL-FCPS24FS8 • UL Listed for • Provides 6 amps • UL Listed for 6 amps 2 operating modes: of 24V NAC power of notification power 4/6 amps in standalone& • Interfaces to most fire alarm 11111 • Power supplyt = 6/8 amps in expander mode systems via supervised advanced switch mode design "0 • Integral battery charger up to 18Ah NAC circuit reduces damaging heat and manages power • Built-in NAC sync, • 4 Class B/Style`outputs up to 50%nore efficiently than other systems for System Sensor,*dock rated at 2.5 amps • Dip switches allow for easy configuration . and Gentex strobes • Each output can be converted • 24 VDC filtered output voltages r 8Flreure Alarms to a Class A/Style Z Mw•.•a Q � by Honeywell using DS-DS9414 Q ' BOSCH M ®,_; „,,,,,,,,,,,, For orders,call: 1-800-233-6261 • For Systems Sales and Support,call: 1-800-234-7971 • www.adilink.com 87 Technical Data Sheet iffsrpERINRE Fire Alarm Cables 2833 West Chestnut Street Washington,PA 15301 "�° Toll Free:(800)245-4964 Fax:(724)222-6420 www.westpenn-wpw.com PART NUMBER: 980 0•10••=0 DESCRIPTION: 18/2 Solid bare copper conductors,unshielded with an overall jacket. NEC RATING: FPLR,NEC Article 760 APPROVALS: (UL)or(ETL)us Listed APPLICATION: Indoor for(Audio Circuits,Control Circuits,Initiating Circuits,Notification Circuits) Construction Parameters: Conductor 18 AWG Bare Copper Stranding Solid Insulation Material PVC Insulation Thickness 0.010"Nom. Number of Conductors 2 Shield None Drain None Jacket Material PVC Jacket Thickness 0.015"Nom. Overall Cable Diameter 0.146"Nom. Approximate Cable Weight 18 Lbs/1 M'Nom. Flame Rating UL 1666 Riser Flame Test Electrical & Environmental Properties: Temperature Rating -20deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 29 pf/ft Nom. DC Resistance per Conductor @ 20deg C 6.4 Ohms/1M'Nom. Insulation Colors Black,Red Jacket Color Red RoHS Compliant Yes Mechanical Properties: Max.Recommended Pull Tension 39.2 lbs. Min.Bend Radius(Install) 1.5" Specification Issue Date: 7/06 This document is the property of West Penn Wire. Standard Lengths are I000ft. The information contained herein is considered The Jacket is sequentially footmarked. Proprietary and not to be reproduced by any means The information presented here is,to the best of our Without written consent of West Penn Wire knowledge,is true and accurate. However,since conditions of use are beyond our control,all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. Technical Data Sheet WESTPENNWIRE Fire Alarm Cables 2833 West Chestnut Street Washington,PA 15301 Toll Free:(800)245-4964 Fax:(724)222-6420 www.westpenn-wpw.com PART NUMBER: 994 s DESCRIPTION: 14/2 Solid bare copper conductors,unshielded with an overall jacket. NEC RATING: FPLR,NEC Article 760 APPROVALS: (UL)or(ETL)us Listed APPLICATION: Indoor for(Audio Circuits,Control Circuits,Initiating Circuits,Notification Circuits) Construction Parameters: Conductor 14 AWG Bare Copper Stranding Solid Insulation Material PVC Insulation Thickness 0.012"Nom. Number of Conductors 2 Shield None Drain None Jacket Material PVC Jacket Thickness 0.015"Nom. Overall Cable Diameter 0.195"Nom. Approximate Cable Weight 41 Lbs/1M'Nom. Flame Rating UL 1666 Riser Flame Test Electrical & Environmental Properties: Temperature Rating -20deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 32 pf/ft Nom. DC Resistance per Conductor @ 20deg C 2.43 Ohms/1 M'Nom. Insulation Colors Black,Red Jacket Color Red,Black,Blue,White,Yellow RoHS Compliant Yes Mechanical Properties: Max.Recommended Pull Tension 99.4 lbs. Min.Bend Radius(Install) 2" Specification Issue Date: 7/06 This document is the property of West Penn Wire. Standard Lengths are 1000ft. The information contained herein is considered The Jacket is sequentially footmarked. Proprietary and not to be reproduced by any means The information presented here is,to the best of our Without written consent of West Penn Wire knowledge,is true and accurate, However,since conditions of use are beyond our control,all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. _ ........._,._.. ..... :.: ;;:.:. ..._.-.,.. „ » ........' s •-----'••- '.." j € €t( � 1: zw o v UWt—t W FIRE ALARM SYSTEM ENS SCHEDULE 1 1- 0 .E.-_ 000 s:-_:, f Zee- DESCRIPTION r� PART B L < BOX y <LA LI A H H3-8 o Z A r1, o CK C3 H ci A cz 1- Y „ } FIRE ALARM CONTROL PANEL _ WALL MOUNTED _ 1 R D) ROUGH-IN - MS, 18 .: 14, ' X f:': £ 'D, H ' _ DOWN TO 1ST FLOOR J-BOX EOL-H3- H o ,U APPRO X: F b R - T O CENTER OF P# ; L, -T TRIM-1 F LUSH TRIG KIT I H3-2 Ig 75 H3-7 Z P Y DENOTES MOUNTED D INSIDE 1 EATHER: Lt < ^r LCS PE 1 D I ✓ -t U WEATHERPROOF C . ( ce `v L: _ I € u. s . / ,�.„,„,,. �wqt a� t_ .`; ,, " __ ili CZ I t, 1 x ; r `` I j I Q A A¢ � Z U t- a.^-^^^ „ :: .. . ... i / ......... I ce Q l� p '-' Z y AW 1--1 t E } Pc I SIGNAL BOOSTER POWER SUPPLY PANEL _ WALL MOUNTED W HEELOCK PS i, /24-5✓P ; 12." A J: x 15,: fH. x 4: a ; I E _ t_.BEDROOM l \ / i \ i , um 1 a - '*- i-I xH F- W U APPREX: A,F.* ; TO CENTER OF PAN-_ AJI SE-7550 1 .. ^ l , . \i [ . F : .... I m \�Si X\ I 2( BEDROOM D I 11 J i 1 : H> >- W W ¢ A O J w ¢ U W 1 ii JF x DENOTES O MOUNTED WEATHERPROOF aCLOSUR` x a A I t\ 1 L i H3— BBA ET D R❑ if \ BEDROOM / -"DI OWN D TO 2 ~�' a q'D A J a r- . :: ; �IHP 120 VAC HARDWIRED SURGE PROTECTOR � K D K _ 1 MOUNT ; 4 : BOX ,U T 41: 17. R PULL , Gq FIRE ALARM WEATHERPROOF 7 AND A HORN/STROBE SIGNAL WHEEL ASW: W . P_D�R WEATHERPROOF ..N. ATION BEDRO❑M •• 1 : ii ,.. FLOOR U BEDROOM T,-. ': STATION � I'• I M F --V Tom - , j LL MOUNTED ABOVE I TSHW y FLOOR �: CENTER ;" DEVICE, KITCHEN i .\ ' a ` ` .r : -t--. ' il 75 DIMENSION IS TAKEN FROM ROM FINISHED FLOOR, NOT FROM SLAB, I i KITCHEN• ITCHEN I` \ \. KITCH EN EN :: s i .� Q--H3 a BATH i •FIRE ALARM ` SIGNAL DEVICE ICE _ WALL MOUNTED dHEELOC MI .S SINGLE GANG BOX _ r__1 „ - - .. : > BAT - , BATH E _ BATH BATH -H3 5 BATH »-; .. a• --• -, H 3 ^: i DIMENSION IS TAKEN FROM FINISHED FLOOR, NOT FROM SLAB, ' - H3-6 P., � ... _...,..r � w - \ 4 ;.' «......:. GH •` c B H - ' ' I LIVING IME ; .._ � � LIV ING = i#_- - S WB SCRIP? BY NOTIFICATION � PP IjN CES ROO '-" _ € - MEOH f # 3 , r ROOM H3 t.. J 2 € ` LIVING 0 LIVING -, ,„ 2t.. , ./ ROOM 1 a ---- DENOTES DEVICE NUMBER N HORN/STROBE CIRCUIT, ,J F 1 f » i O DENOTES HORN/STROBE CIRCUIT NUMBER DEVICE IC TIED TO, 9 ..w _.-.._-----"c S•a„mmi� ..... - .. w�aw"r _ .-.•--„-...a!,aw„.x^. _ ,.....«... C............... .,...,..,A3 �a x o 1 I . w -``• A - ssA_ L E SMOKE DETECTOR _ CEILING SURF A ,E O JN? = E.r,_. SIGA- S ,; _AD) ' OCTAGON BOX _ 2 °1/ 1 DEEP € . MASTER BEDROOM .t MASTER BEDROOM MASTER BEDROOM '\.12 CP DENOTES PHOTOELECTRIC TYPE STGA-SB4 C 5 BALCONY _ z BALCONY BALCONY MASTER BEDROOM • 7,. BALCONY t 2 R wffat .,,-..-•.--,..-..-... xvxs i ADDRESSABLE : A- DETECTOR 1S-t FIXED TEMPERATURE TYPE, E,S.M, 5�� � - S (HEAD) r OCTAGON B f� _ �-z MN �h-� ”;i_, .�-•�•, ,t ..c Y�^•^ , .hv�.. ,...: e s, F IN ELEVATOR EQUIP, ROOM ELEVATOR SHAFT ER PIT, MOUNT S_ A S34 (4' ASE) ..._..>.: �-•�»�..,» �«,.:«.�ce.4,. �� ---- ..i . -,. WITHIN 2'-O” OFF SPRINKLER HEAD, CEILING DR WALL MOUNTED 3RD FLOOR FIRE ALARM PLAN ;.7. — ADDRESSABLE CONTROL RELAY MODULE - E,S,T: SIGA---CR 4"5Q, E-1/;D"DEEP WITH SCALE: 1/8" = 1 ,_C,r MOUNT WITHIN :3' 3" OF DEVICE TO CONTROL. SIN LE GANG PLASTER RING w 1- aa ADDRESSABL SINGLE INPUT MONITOR MODULE - WA«.L MOUNTED E S,T, SIGA- CTS. 4',SQ, 2-1/8'DEEP WITH C-1 FIELD VERIFY EXACT MOUNTING I..- .0 ATION, SINGLE GANG PLASTER RING Z ADDRESSABLE .T`-R;- LD\'/TAMIPER MONITOR MODULE - E.S, ; , SIG . W . , . --.- ..., ..,_.. _ r . - , ------ , r..... - -. m » ______o -• w �I TI�1DDRESSAl A L �`' , f ` N 1 1 F i MOUNTED ;:..•A"' PRINK TAMPER R ANI.: . .--1V�' SWITCHES, SINGLE GANG PL PLASTER RING €\\` .. i.. 3 1 M f A;_.;_. N: .:\ S. i ...}iii\ ...: E ' i:.. �cn S R € IL.L..:; /CR : Y EXACT MOUNTING E... PA . II; , DOWN TO 1ST FLOOR J- _ I H2 H2 8 H i w r,1=i co CU - PULL t: r Y ... c _ �::';_S WEATHERPROOF ! BOX EDL H2 ��¢�� : r �. t C WITH SG-WP P �L I z/V I _ _ L- I , VIP WEATHERPROOF . S } A i A� �� SC �. 1H2-2 ».,... , H27 ;=gco.D WP r _ r.VI W EA . F ERt R: O: MANUAL : UL' x »...,.ry, :.. • 2 2 D R„ : P i .s 3 MODULE •: B i ..... Q' Y e...," ^....... , •'..•.' «•"" -.»»`», ;ml,P7 _I t"�OD i' ADDRE,. .. t 1�SI.:.,l.._ BOX 3 lrrtrrr 'f� ............................ C�^7 SSABLE ...°;. ... >.».> .<.: ::.... . , J MD 7 .-.. ,.- >-- .-,F- , , t .. . . i=r IE _____77„,_t I H CMl.i O�`, ,.,,_... ., ,�,_. F d T , , , i. Y Q_ f 11 : , WITH 1- _,S. , , S . C lam: _, BEDROOM ILwN MOUNTED: E E AT, :�R, ROGF -3� FIXED TEMPERATURE ❑ �E � M=131 EDR \ w 1P � t ; ` rn HEAT DETECTOR WITH; ADDRESSABL SINGLE INPUT :MONITOR -�,5, , SIGA-C•"1 9 r D E r t ,, BEDROOM t' ��• w ODULE INSIDE BOX > :: .. I t '1 DJ :.w; :;t; �oox I .......... F , , BEDROOM II • BEDROOM — I -. ;.. BEHIND:Y r„ KITCHEN if 4 i1 .--tu_o .... .,... «. ,_. RESISTOR... .,...,..,. E ?"- i-�r• i i >b ' s } rt: \i.,y q.}:.., /} ..__ s ____ �.: i i£ - :. - VALUE ANL AL 1L S € L1 N . ' . P<M P , z If C3L-,r�. lI G{ L� L�iS1 , . , FT % 1 U TO 3RD o RLCJIREP -NTS, L. ' ` �' FLOOR PULE + 1 BEDROOM M.;.. ..€ a •�—�.. i :` :.:;::. BEDROOM (IBC wo_M\ D TO 1ST .a M i t .... r.i :•• .!``,.._ •• i �, !',. 3 }r* r. } ,~� < ....._«........: i,.,.•. -- .- .. 3«<«<0><«<..». r p E W C+N') EDLR T: POWER 1 /PTVOJiT �° SC, �IJL3 ✓Tz � CX H2 u, C �!E RELY dD CF L Y r . : �: .. ., �;,� i �f I ;�- F SAT J IC F,'STATION . � IO � • .......___"- �F ,.... � KITCHEN s :: €ar..., ; ,. � .. ._..... � tom..c�¢�r� . € '° $ KITCHEN D �A ctiE / ms's. • L 24 of.,'i DP DT SIB: (:E OWN/SI- UN I TRIP P CON E RL L 1 '�.._..AY AIR PROD. PAM-1 1 t'"�OUN i� IN JUNCTION IO3� BOX %' »» ' 0 try f t < : . , ? BATS € FIB'' :E ..• , f tn t WITHIN �� I DEVICE E. I, 4 , ... i BAT BATH a ? I , c,•,z..-, -4t-� I I f BATH 1 BATH (: ..,, vcWi�—o .B BATH • H2-3 - , H2 w° : ._ I i:" ..._"" H2 •f •'« H2-6 Ll.� :::c'' ��:a f BATH r n MEGH �.i..: MEt (� CLJOX} C t LIVINGMEC)1# f• r ��! J '}. x E H IM €I Ii1 6°¢dW: I U, >ROOM LIVING -- :..�. I fti _ !/� I w I:II ROOM H2 7"' / _.., ECH LIVING ;I, —pp r ,M_:.:::::: r. f J'� n LIVING ROOM <, Zµ•, ,t . / I ROOM —kn `�=" Y" W L / �., z U ' .5• i I\4'(_..,... -r t fu'3-L.P .1. '3 f l.:i�t E" %._...D V,'"...:'C). ,...F\: i., i ......:E.,f-': ?i..E 1V E'd L.i 3 ;J ' ,.3,S, E R;..i V ?i.l E 3J 7.7�i' L: I"'E�::. S ........ s .tt,""..=:� -..: :3...«.«a-.....",.•^-r . .cC N- � y q Q�cL MASTER BEDROOM • MASTER BEDRO❑M MASTER BEDROOM -oc Ewe <C;�-•--E.3 S'-�R�<.INK OW SWI C�_1 _-.. '>=ILL R r:t XA1 T ATION I - I Y si:5.'C, PR vJID' I f O € H tS __ BALCONY '`\.., BALCONY - « BALCONY MASTER BEDROOM �` >—Si icP\ r.. BALCONY O d1_,- M W� r _ P PIPING �d'.- ! I7y ,�r.>:... { L. VII ..s » N } "-Y: I n :L jUNCT E CN X . OR r IRE . , AR s _ u - r .., , W x `,,,",�1;^e�„",>' ,uw,.,,!�.,• :-�!, p,�, c».�b" lr, ',;;' +-.,`. -. ..---:z `a`"`x`y,»:x,."..:u,.., �:.�,+`n uaxv i,.,x< .,� u,..�,,,,!a,..r `- ---- - 24 VDC FIRE AI A, CIRCUIT:• RUNS IN CONDUIT,, 9' #� - DENOTES CABLE TYPE IRE ALARM P A R D FLOOR FIRE ' , ����, --.< an�o x SCALE: 1/8" = 1 -O" ----- �f.,, ..,.� 120VA�C CIRCUIT FROM DEVICES SHOWN 1 1 J.r/ ti J.S.C. JAX, SO ND & COMMUNICATIONS E.S.T. = E:DWARDS SYSTEMS TECHNOLOGY ESL -- ELEC I RD SIGNAL LAB A.F.F . -- ABOVE FINISHED QED FLOOR L.1 CO E.:._ flinch r \ FIELD VERIFY EXACT LOCATION CO Lf7 r. z•`;-. .--,t-� —r+ .i i'-\ DEVICE i T 't .^ TYPICAL l r/ '! 1 i• TAMPER W TYPICAL A .IRESSAB_E DETECTOR Dt I ADDRESSABLE MODULE DEVICE o �'• �- } I TO DEDICATED 120V � � � '�'```'``� ,?'2 DEVICE J s AC I \.,...'f-' m-326 r....._.�•�-x-;....»,..� -;-.>..., _ �- :>:;.: ;:a:G,_--^"=s„ _.� _....�<. _. ��.:. .__---•^'---__-___._::. __,z�`:«^•^� ....... ._.a�. ^'»»^^".� - .--..��^«�..:M•^'m ............:�::.x._ .s_--"----�.. _.,.,--n..'`�».»»»�»:`" f.�d��-0 Pi- - -� € IP TO TELEPHONE BACKBOARD ;I € ,�„., _«T DEVICE NU BE:R ,h E � 1 TELEPHONE CABLES : ! .,.-.Z NOTE!E' ' �DJLS FROM wPE mm I L '-:::.v::::.:::::r.:.._::»i _ CZ) 4 PAIR #24 AWG, R DENOTES A DETECTOR DEVICE- T _ t _ _ 1 En-, rI°"1 :E ... 4. E 1dF' M- i M-128 ' F �I.i ;..,S ;..,...: D E.. ..- TES S . , . .,--t D,.j�...-.. DEVICE } t , • i : • t FMS : " NUMBER D,DR : 1 i 1 11 - . ; .. R : - M-127 12 C'�L i L .J�. 1 :: .... T ° € \. , Imo.. I wEDL-Hl 1Fgj M-129 • TO DEDICATED 120VA , D,DR I_ _ (I) N. :a..11,6::,: ( c� < 1 -130 il H1,H ,H3,H4 •, t /::::t_46112 }-: Z - 1 . - : 1 .. •E v , i-. tY..1 E H1,H1R,D,DR t ••.......-.....DR I c t iw` - F S /f H1,D,AP D ......... HI,D,DR i o ry UP TO 4TH FLOOR-0-1f H1-2 METER CENTER H1-3 ; o MINIM 11 CO D TIT SIZ SHALL �� SIDE AS NEEDED DER NEC. _ HORN/STROBE 1 • 1 Li Q CONDUIT r, PULL STRING. N' i H4 , , p H1,D,DR i II H1DA \ 2) ALL e„ONDUIT SHALL BE FURNISHED TH .� N P L E P1; IG> ; E n. r : aj I O A 31 DO ND- INSTALL CEIUNG MOUNTED SMOKE DETECTORS WITHIN 3 FEET O. UP TO 3RD FLOOR ' •� D 0 Z 00 p4 - A R DISCHARGE GR LLES, 000 RD NATE WITH OTHER TRADES AS REQUIRED, .,.. UP TO ROOF LEVEL ••,C J i L EQUIP. ROO M ,..-I UP TO 2ND I 0 5- FIRE ALARM CABLE SCHEDULE DETECTOR HEADS MUST 3E COVERED DURING CONSTRUCTION UNTIL FINAL CERTIFICATION GY JSC. FAILURE TO COVER HEADS FROM DUST OR DAMAGE FL 00 R- g' FLOOR PUL D A P , w o COULD VOID WARRANTY. "THEREFORE, . HE CONTRACTOR RESPONSIBLE WILL I.j.,HORN/STROBE H2 STAT ION ,5 ; , . DESCRIPTION E �OL 1 ¢ U Q V aY a_ BE SUBJECT ED TO THE COST OF REPLAC NC OR CLEANING THE HEADS, , Z pq o A D DATA 1 PAIR #16 AVG. (FPL) RED JACKET I t > 5\ NOTIFICATION APPLIANCE CIRCUITS f C SHALL BE STYLE '4 - I v —� ] 1- DR DATA RETURN 1 ✓ AR k:a Al . Cc RED JACKET (TAPED YELLOW) E 1 w H# I"fL11 N/S.-«k1..'-JN- 1 FAIR #I.4 AW:. , (FP...) RED .JAC.KF..T �.... .. . t I H#R HORN/STROBE RETURN 1 PAIR #14 AWG, (F PL) RED JACKET (TAPED RED) o) INITIATING DE '€4E CIRCUITS DC) SHALL BE STILE A (CLASS t3'} WIRING, t 1 1 a- I W #`. _ DENOTES HORN/STROBE W<RC Iu:T NUMBER 7) SIGNAL..I.-ING LINE CIRCUITS (S_.C) SHALL BE STYLE fi (CLASS 'D') d RING. 1 1 I W DENOTES I „ 8) WIRING FOR ZONE INITIATING AND INDICATING CIRCUITS MUST 1 #— STYLE A Y ZONE CIRCUIT 1 PAIR #t A G, / } ) QED JACKET 3 INSTALLED IN A CONTINUOUS N FROM DEVICE (rDEVICE _v � � - \ � trr 1. Q LD � . F: 1 , t i. » ?`z ! \ w - _ ___-_ # - Nl L Or 'AS w.. WITHOUT N ' , _TABS. � � A t z$. _ i J ,`l\ ? J , J , F i ' F , ` 'MIRING' _ ✓ THESE CIRCUITS MUST . > N- i -: / \ .` \ `: \ - i \ `.` r \ E ! \ / \ 1 € / I1 r:: ~ AP AUXILLIA 7Y POWER 1 PAIR #I °� ,_�. RED JACKET ._ / \ i i I \ ` M H _ ) 204AC CATED BRANCH ROUT SHALL BE MECHANICALLY �. W > co In PL l BT BOOSTER TRIP 1 PAIR #14 A ° (EP`-) FD JACKET PROTECTED. THE CIRCUIT DISCONNECT MEANS SHALL E MARKED IN 1ST FLOOR FIRE ALARM — PAR <ING\ G AR 'AG,E ` i - EL ELE VATOR LIGHT (FIRE HAT) 1 PAIR fi14 AWG, (EFL) RED JACKET ED, ACCESSIBLE TO AUTHORIZED PERSONNEL_ ONLY' AND IDENTIFIED ‘--I ° V) AS „FIRE ALARM CIRCUIT". LOCATION OF CIRCUIT D SCONNECTI'C SCALE: 1/8” = 1 ,-0> � 0 � E R LL..LVA CI: : : ! A _: 1 PA_` #1.4 AWG, P`•"-) RED JACKET MEANS SHALL BE IDENTIFIED FIRE ALARM � NTRO.. UNIT, AN D a� � d up„,,,;---- R' r ,... �. - h T OVERCURRENT PROTECTION S L B E P R O V D E C DE PROVIDED. - v ca r i" - [\ 1S; PRIMARY RECALL) H,. . DENOTES SECONDARY RECALL (COMPLY 4T NFFA 72 4.�,�,4." T> RJ 4.4,1.4.4.) Chatham Count� Q 3 Pt a a ST SHUNT TRIP 1 PAIR #14 AVG, ( PL) RED JACKET Inspections Department g , g �k € 10) IF A DE TECT R S LISTED AS SUITABLE FOR WALL MOUNTING, IT MUST °� �t�� ` DESCRIPTI❑N s BE MOUNTED BETWEEN 4 INCHES TO THE TOP OF THE DETECTOR FROM REVIEW FOR CODE CO-"�T,.':";nE � � FIRE ALARM THE. CFII_.IN G> OR 12 INCHES TO THE. BOTTOM OF DETECTOR FROM q a� SYSTEM •.-: CEILING.tG :^,G CANNOT " 1, y, 7n.+, n ._•----- � 3 THE CfEfL;N�. TAE DETECTOR'S Eu:�E CA:�t��,i EN MOUNTED LESS THAN Every effort e-1 '^ _ y _ OPAL ,�- EQUIP. SCH<) ..�., FROM '°': s-_ CORNER,... tf, .- .-i.; CEILING y.-,, r: W °-x ?.{-- ors �� r �° x , 1ST, . INCHES ; ROM i; OR R }HLRL CEILING AN 4 code V, o..�,:.. . '3 no o1%c %: b, _ i..� ,/..\ ..\ I , A H ,: N� WALLS SEW: r �h� D, reviewer shall be construed a-> �1.�?'''(,: ;, ty } 8 •u � z~� \,-..1 \-- `s, .,,- I \,_.,i I `' , /", ( ` `«'\ FLOOR PL n tl �.---Y•- ; ,) SHUNT 1P i z - ws L € PLANS; �'`�.� . €) Sr-;w'N; I'�I, �, RuI�II "ST" MUST 1�� PULLED ?`� A SEPARATE to tii, �z .e � u o?.?.:e , c•s.,.l•.• alter or set aai .a Y1S1©n �• ' aDi i.. .,.v. ..., i ;i... ,.. _ ..f.. ,i PULLED, ; ; Y CONDUIT! IT SEPAI ��TED FROM 1 I IRE ALARM C FAG J TS. oa . c:� , The Jacksonville Sound&Cct mmunieations,Inc. 5 . E } UA�LE TYPE SHOWN A(� JR CABLES P JL�E sL1;�CONDUIT, �. r `� 2219 B Sac• a 2;`' co^es or o"°_' na zc^„ c�e S' } THE „r DEVICES ,i BE e ry n �n ,} ..,;n.;_ li,LX2-------<A--,2 Rowland Ave. Savannah, GA 31404 IF WT RING ; € �V RATED TYPE CABLES INSTA Ll3 IJN OF E WIRING, RACEWAYS,5 t Y CEVICES WILL E r _ .. =o' '_a �. be construed ....,_./% �im IF OPEN ��WRI=NG AND CEILING IS r LFNUM TYPE,PE, USE PLENUM RA r ED r PE \F-PL ), __ _ IN ACCORDANCE WITH ALL APPL CALL :,OUNTY CITY CODES, as a k�-� r _A ni e _ PHONE:(912)303-0310 FAX: (912)303-0390 r r �• r ^y j�j g. - SHEET NUM, : FLU F R O I•\ B RATED i- Y UNDERGROUND i E LOCATION, i1 T EDITION IF R `E RUi.ES AND •3 u.- 4, 'F �ALS ARE Lz II�� RL1d ; SE CAS- A , I} ;�' 4L�E,t R N 1 NE PA �c CODES, > \. 3 J❑B NUM. _ _ k �/ � Georgia License Number: LW40S400 REGULATIONS OF THE STATE FIRE MARSHALL'S OFFICE. /f Reviewed �� Date Licensee Name:ame: B r an Stross F ® 01 S06-053 Signature: - - ------- - _........._ ... - • ; ___________ ..___________ NAC VOLTAGE DROP CALCULATIONS WHEELOCK PS-12/24-8MP 8 AMP SIGNAL BOOSTER POWER SUPPLY PANEL (BPS) BATTERY CALCS. FIEM3 ALARM BATTERY CALCULATIONS (QS I-1-R-I) Z P1 t- I-I 0 W <1-1- 1- EDZ VOLTAGE DROP CALCULATION'S DESIGN THRESHOLD (NAC) NOTIFICATION APPLIANCE CIRCUITS TIED TO THIS PANEL - H1, H2, H3, & H4 EST QUICKSTART FIRE ALARM CONTROL PANEL 1-1-•fY X Z CZ ._ LA SUPPLY VOLTAGE= 24V 0 ec _i ci z 0 p TOTAL TOTAL DEVICE STANDBY T TL ALARM TOTAL FIELD ADDRESSABLE DEVICE TYPE ,x .cr uo cel_._ MINIMUM VOLTAGE REQUIRED AT EACH NAC DEVICE- 16V (PER MANUFACTURER); Notification Appliances Description Q-Y: STANDBY STANDBY Ai ARM Ai ARM QTY, CURRENT (ma) STANDBY (ina) CURRENT (ma) ALARM (ma) o CURRENT= 80%OF CIRCUIT SIZE (EXAMPLE: 2,0A (MA.X) x 0,80- 1,60 AMPS) ; (Amps) (Aripc-,) (Amos) ' -- 51-1-(4f4Z < Lice el CLASS B - STYLE "I'WIRING; CABLE USED - #1 4 AWG.; , - , - u X 025 0,000 0,4 0,000 11 1 <PIal<Ers-ViZUF- NOTE: WIRE RESISTANCE PER 1000 FT, WTRE (PAIR) ;#12 AWG. =3.5 OHMS; #14 AWG, = 5,2 MINIS: #16 AWG, -- 8 OHMS MIZ-P4S-Nd Temporal Mini-lHorn 1.%.3. X N/A 0 0,026 0,312 czw z pi 0 0 ci ''''4 Z ' . 4. SIGA Seri 1--- Series Detectors 6 X 0.045 0,270 0,045 0,270 mX1-41- 1411.) I I 0> >-LALJ <EPI (NAC) CIRCU T TO RESISTANCE VOLTAGE PANEL VOLTAGE TAL WIRE END OF ASWP-2475W-FR 75 CD Outdoor Horn/Strobe 15 X N/A 0 0168 2,6 88 -------- _ . SIGA Single Stage Pull Stations t : 0) n X _ -----------------------------------------' .o ...i Li <r c_.) w NOT F. CIRCUIT LINE 0 025 0,000 0,4 0.000 7 ET-rTEJI=IF-W31-6--FT- APPL. LENGTH PER 1000 T. DROP B_ANK VOLTAGE DROP X N/A 0 0 0000 CURRENT VOLTAGE SIGA Two Sto,oe Pull Stations (SIGA-278) 0 X 0,396 0,000 0,68 0,000 ).- C RCUT (FEET) (AMPS) FOR #14 AWG (VOLTS) (VOLTS) (VOLTS) (VOLTS) TO-AL NOTIFICA-MN APPLIANCE ALARM CURRENT (A) = 3.000 ---- -- NUMBER (OHMS) SIGA-CC1/2 : n ! ' X 0223 0,000 0.1 0.000 O 0.45 . 23:55 SIGA-CR 4 X 0:1 0,400 0,1 0:400 1000 = 0,45 24 .... Hi 130 X 0,672 X 5,2 0 - . .- . . e TOTAL TOTAL H2 280 X 0.776 X 52 4 - 1,13 = 22:87 STANDBY Ai .ARM Auxilliary Devices c TY. STANDBY Ai ARM , n --)K.-:. O 4 - 1P1 = P:79 (Amps) <Amos) SIGA-CT1 ..., X , ,.) 111111111111.11111=1 3.600 H3 300 X 0,776 52 ;;-- 1000 =- 12I i (Amps) (Amps) ------------ H4 320 X 0,776 x 5,2 -- - 29 1033 = I 1, I 24 - 1.29 = 22.71 End or the Une Power Supvisory Relay 0 X 0.015 0,000 0.015 0.000 SIGA-CT2 1 X 0,396 0.396 068 0.680 z 12 __.._.__......__..___ - — Misce?it 0.n e ous 0 X 0 0,000 0 0,000 SIGA-LED OR SD-TRK 1 0 X 0 0 2 0000 .94 m c.) LA . Aux Wary Mtais (Amps) Standby (B) = 0000 A I a r m (C) = 0.000 SIGA-MM1 0 X 025 0,000 0,4 0,000 m .....----- ,,,,--- SIGA-UM, Personality Codes 1,2,3, or 4 u X 0,396 CO3 0,68 0.000 '01 NOTIFICATION APPLIANCE CIRCUIT (NAG) LOAD CALCULATIONS , > 1, BASE: PANEL COMPONENT STANDBY CURRENT (D) = 0.060 SIGA-UM, Personality Code 8 n ,) X OA 0,000 0:1 0:000 m PANEL & ALARM SUB TOTAL STANDBY CURRENT (B) + (D) = 0,060 n CIRCUIT # SIGA-UM, P-Codes 9,10,11,12,15, or 16 X 0,222 0,000 0,365 0,000 OUTPUT CURRENT TOTAL , DEV CE IS NOTIFICATION APPLIANCE DESCRIPTION OTY. NUMBER DEVICE S T ED TO TIED TO (Amps) (Amps) SIGA-UM, P-Codes 13,14,20, or 21 0 X 0,1 0,000 01 0,000 I BASE PANEL COMPONENT ALARM CURRENT (E) = 0.100 SIGA-WTM 1 X 0.396 96 0:3 068 0680 SPE-OUT 1 H ASWP-2475W-FR 75 CD Outdoor Horn/Strobe 4 X 0.168 ,,,,"7,7) o,o(c: TOTAL ALARM CURRENT (A) + (C) + (E) = 3,1.00 SIGA-IM X 0,045 0,000 0,045 0,000 NOTIFICATION APPLIANCE CIRCUIT (H1) TOTAL At (AMPS) = 0.672 0 w 1--- II± I • HP MIZ-24S-Vi Temporat Mini-Horn 4 X 0.026 04-- Totals 111111 5 a'63 SPE-OUT 2 ------------ -----------——- - ---- . --- ------ H2 ASWP----2475W-FR 75 CD Outdoor Horn/Strobe 4 X 0,168 0,672 DESIGN PARAMENTERsi SUPERVISORY HOURS = 2 m -..._.__ ____-- -- .— ----- NOTIFICATION APPLIANCE CIRCUIT (HE) TOTAL LOAD (AMPS) = 0.776 ALARM MINUTES = u,--:,- I 1 -- ------- ----t-- -- _ _....._ H3 ML-24S---W Temporal Mini-Horn 4 X 0.026 0:104 ALARM HOURS = ALARM MINUTES/60 = 0,383 Main Panel and Remote Annunciator TD..FAL T ITI AL SPE-OUT 3 Q TY, STANDBY (ma) Al ARM (ma) - 1_,J c3c.1 cu N- E c uip men t Description STANDBY (ma) - " ' ALARM (ma) H3 ASWP-2475W-FR 75 CD Outdoor Horn/Strobe 4 X 0:168 r;..---7 BATTERY CALCULATIONS NOTIFICATION APPLIANCE CIRCUIT (H3) TOTAL LoAr (AMPS) = 0776 REMOTE ANNUNCIATOR 0 X 105 0,000 123 0 .... ..1=4-...co Standby AH = Total Standby Amp(s) X Supervisory Hours = 1.44 AH i ,--- 1---1...- -•r--. -`7.I=c„,,i•C",.,-.. H4 MIZ-24S-W Temporal Mini-Horn 4 X 0,026 0:104 IQUICKSTART FIRE ALARM CONTROL PAWL 1 X 199 199,000 235 2-:z5- SE-OUT 4 , Alarm AH - Total Alarm Amp(s) X Aitc.Irm Hours - 0,26 AH rze--)>—4.#■—• L..; H4 ASWP-P475W-FR 75 CD Outdoor Horn/Strobe 4 i X 0.168 0,A72 .-- i 4:'t Tr 33 33,000 57 57 eco:e4=4›.‹ , MINIMUM BATTERY AH REQUIRED = STANDBY AH + ALARM AH = 1,70 AH NOTIFICATION APPLIANCE CIRCUIT (1-14) TOTAL LOAD (AMPS) = 0.776 I L-1 1FRONT PANEL LED/SWITCH MODULE 0 X 5 0,000 75 CD ..... Minimum Battery AH Required + 257. Addition = EStandby AH 0 o ;:),1 2 AH Z + Alarm AH] X 1.25 i . I ZR88 8 PROGRAMMABLE RE! AY S 0 X 53 IIIEIMIIIIIIIIM -otal AH battery beino provided = (2)-12V 7,P AH : . D 0 d'D leit:trcrk9r, I DLD DIALER , , 1 , X i 13 13,000 20 PO ......... 0 Z ZB16-4 ZONE CARD 0 X 123 0.000 123 0 u (1) 0 — '•t •-•.'-•_52E h j gi I-- ;-: -'41:.c-)c( ,)■•,Zg; • Smoke Power, 4 wire detectors' I 0 X 0005 IIIEEMIIIIIIEIIIIII 0 L.L1 NO-1; 1 1 _.1 <0 rl- -2.Ltj'. . : RE AV RISER DIAGRAM IS SHOWN FL-JR DIAGRAMATIC PURPOSE ENLY. __I 0 - REFER -0 Fi DOR Pi AN FOR ACTUAL LOCATION OF DEVICES) CONDUI- NC & AUX: DEVICES i — z ROLJTING AND WIRING DT DEVICFS, Output #1 (BT) Boos-ier. T—rip7(PS-12/248MP I -..,--- i I- Panel) " 1 i I 10 10 Z _710 ,:1/47, i ____. __. ____ ,c), iti-)i-g ,ELn ' output # '<SPARE) f 0 1 X I N/A 0 0 0 --I E Cel ON CU Q ; I I 0 - i...,J-oh. CD D i i O 0 E ,1 IF _, End of the ne Power Supvisory Relay i .1. i X lc: 15,000 `I'• 15 1 ,,,,,,,-......1,-,zt-,:-., . . i (,) o L.,. ...._,„..,..„ D-005 N co cP D ..-, cu D-004 m cn (,.ii "4.' Miscellaneous 0 I X I 0 0,000 0 u .<1( e II I I I — 5.630 I ce= 1 L=.3nEn, D ,.' x z x x x x . Totals from Above Worksheet N/A N/A 3,712 N/A 7f)F, E.1.5: KI-1*-F%'.145-13-17, 1 OF D-006 r -, ---t :71; -:+41 D-003 TOTALS IN MILLIAMPS (ma) ---------------------------------------- aEENIIIIIIIIIIIIIIIIIII 342.63 ..J . i. I ,,D I t- i•51-7 -I ' cu'" • Fi FV, SHAFT 0 : :51. -cti 1 WI Mai CONVERT MILLIAMPS (ma) TO AMPS (A) = MD LIAMPS/1000 0,264 0,343 :-.'-'14-)f--"231cLjc,q571-1-7:17:6r: „.. d r.g \-\/-__ Lij 1 'W °.- >.:Z >Z i 1 0 Z ,,; Lai GI LK -- ----- - -a., DJ Lii DESIGN PARAMENTERS: SUPERVISORY HO.iRS = . o m _1 .C4 a. m 0 1-1- CI Q I'',.0 . LI 1-1 '- i_i: k ALARM MINUTES = 1111.1111111111111111111111111111 -I re 4.1 -- C L M- o RALAROU x = ALARM MINUTES/60 = IMIEMIIIIIIIIIIIIII I F- AP ROOF LEVEL , BATTERY CALCULATIONS EL.Ev. t.::cull,) -------- _ - ---------- _ i Standby A = Total Standby Amp(s) X Supervisory -lour s = 6,33 AH (/) i-H4 v v7,/,E, Alarm AH = 'Total Alarm Amp(s) X Alarm Hours = MOM AH M-136 M-135 A -,--=----go■TO HORN/STROBE DEVICES ON CIRCUIT 'H3' ......... Cil. CT1 D <E FL' WP D H4-1 MINIMUM BATTERY q REQUIRED = STANDBY A-: + Ai ARM AF = 6,36 1111111111111 ----- IF. WP (s- .1 4TH FLOOR Mmum Battery AH Required + 207. Addition = Z OK <E EStandby AF:4 + Alarm AH] X 1.20 11111111111111111111111111 o x _ 4, i Z LD < N Total AH battery beirio prov de = " I (2)-12V 12 EMI D 0 c:27 Ei.. V5 _ H3 v yf: M-133 M-134 1 l'-=1■ z TO HORN/STROBE DEVICES ON CIRCUIT 'H3' ICT1 1 CT1 • Z _J z _ m 0 r R '' •„." H3-1 m w fil wp D WP 0 Q Z ro 3RD FLOOR L ..T ..c a. Li o ix II_ - z pq V) Pt < >- 1 . 6 Li_l I- D tli D r2 y7 ,4E 0 TO HORN/STROBE DEVICES ON CIRCUIT 'H2' ce Z M-132 M-131 0_ _ H2-1 LLI cfli un F 7 : 1 ,p D ' VP B-, 2ND FLOOR > > - <,:t < 0 ---1 ,,, < [Hi v‘,/,: CY '''' I- LA=-31■•TO HORN/STROBE DEVICES ON CIRCUIT 'Hi' CZ cp - M-126 • 1 . 11_1 _1 co n 12,21 TO OTHER ADDRESSABLE DEVICES ""7--p . > co I-I CD D WP Dj I H1-1 J-BOX 2> 0 I (0 AP,D,BT o C di- o—H1,H2 , ,H3H4 a_ --5) 4 6 r 0 TO DEDICATED 120VACW -NAHPI 1 \\\ 11-1P1 LT'J -7'."-TI" 4 — I-- 1 .,:r 3 Pt PI PI TO TELEPHONE 1 F7Acp SPE 1 DESCRIPTION BACKBOARD SPARE Hi. Hp 1 z WEATHERPROOF ENCLOSURE (TYP.) FIRE ALARM (2)-4 PAIR #24 AWG. BT • SYSTEM TELEPHONE CABLES P I H3 I SPARE FACP BATTERY CALC.; iL AP .,.......‘ BPS BATTERY CALC.; BT INPUT,-At-BT-EOL • , , . n : 1 '\ \ / --: • : --...., NAC LOAD & VOLTAGE DROP CALC; .............. .............. . ._..._.._ _ _ _ BT 1ST FLOOR a Division of Iacksonville Sound&Communications,Inc. RISER DIAGRAM _ 2219 B Rowland Ave. Savannah, GA 31404 PHONE:(912)303-0310 FAX: (912)303-0390 SHEET NUM, JOB NUM, 17:1 nr: A 1 A 7:0:. A Dif.r.n:,Q no •% e-.977,7: A. p,A Georgia License Number: LVIJ405400 ;. ',, pkg.-PA livl 1 1-:.,,,-)L,l' f ,L)1,; ',.k.,Ar liA.ev.1 Licensee Name: Bryan Stross NOT 'TO SCALE FA.03 S06-053 Signature: _ _____________ _ ____ __________ ____ ____ _________ _ _______ ___ ____ _ tO3 OF 03 ________ _____ __ _________ __ _ _______ ___ _________ ____ ___ ______________________ __ ___ _ _____ _ ____ _____ _____ _______. _ __ .- ----------------------- --------------------_______ _________ _______„ _____ _ , Z Li 0 0 C._)LJ!--I LI V5 — — — — — — — I .._._ ..._... ...__. ..........._ ..._.. .,...._ ...,._.... __ .____ r-M DU\T THESE DEVICES . . _____________ . _______ _ 1 z pal- r-i 0 D -_ - — — 1 - , BY THE BREAKER PANEL : TO ELEVATOR u_z1-1-MX ,ZCZ‹ 120VAC ' ELEV. SHUNT Li CONTROL PANEL TR IP BRE:AKER NTRO/ H N -------- •'OTD THIS RELAY IS SHOWN A, ..i x OCZ Li __ - _ __0 ., ..„ ...._ DE-ENERGIZED. IT ENERGIZES WHEN THE HEAT DETECTOR IN THE ELEV. EQUIP. RM, OR TOP 1 t t 1 i , 1 120VAC FEED (2)-#14 AV/G. R -AA... INSTALLED IN TOP ,. • i .... 0,0p412 -- DI -0 ,--I INPUT TO ELEV. : " '' D / il t • OF SHAFT GOES INTO ALARM. nMOUNT THESE OF ELEVATOR PIT : 11 '''% S TAI R D,DR,AP _— FIRE HAT 1 DEVICES BY TO ELEV. SHUNT EoL-------1 1z 1"1" I/ THE ELEV. TRIP BREAKER x-, 1---• L....1(..) 47K OHM 1 ::.--,:m TO SMOKE .is.* „ 1 ,......;._,......i....._ ----1 C --EL CD--ER I ,... ER2 criNTROL. PNI., M-137 LK : • . , DETECTOR D 006 .,-, Pr:: DOWN TO 1ST ::.:i?... .-":„. ,:,.,..:,,.! ICYZr=“:1CGOLLI ..-M-...4 .i : I • -SYMBOL GYP. ) D,DR,AP,1Z 4P T FLOOR J-BOX MECHANICAL CY : AHU-2 a .:1 li :. rj,, ,,,,,,____, .., lz-a ,....:AA.._ ,... .,... ... ROOM es ,, DAP r D 1 gri. Lt1i .' 5 %-,! ,‘;1 4 1 ICR CRI Li 8 7 6 K_. -4/-,1 D,DR,2Z 7 D-003 ( P iF 0 0 0 i 1 il.E.1 .1-6-. .,. --- 7-.-Zio 1 . '1---. "EMT --- . , , . , . , . : I : . AUX. POWER & .-,--,-, M-138 - --- • -, % - -- :in 2 ATO, 4 I=Ur' w .:...!I: ,, ELL 0 .;- WWII : * 4 API ,..,_ ,, * 0 2 2 L EOLR . 47K ' 8 7 i 0 0 0 I . • , I 6 7 6 a a :me 4=28tr" i• 07 0 0 WI:Tr' 07 a. 0 r i :.:20.g.. fEil ELEV, POWER MONITOR t,.., C.. , M-139 — ---..—....... .—..—____...—__ _..—.—.....—__..._._--,...1 . :L . 11 : f PU P 9a° lb m......-----. ---• *--- I 757111i- 1 -4,-- EL D,DR,AP / ....- ............... i ISIOACT2 i 0 o 0 01 : 0 OM 1 i <„, .„, 7..._ : : ° 8 3 2 1 1 L. . ME ... 1 4 3 2 1 " INPUT TO ELEV. ; CR. M-140 ....,. 2z ; -I- I FROM FACP H> . I 0 72 0 i - . mom . .:11, :ousfasio . FIRE HAT IN CAB ER1 ... , , (-) :-MN _ , (---,--, M-141 1 AP Do : Ill -- . - • : L, \' 1 , , , , -AP D?) . D j " D D D : i . TATA 1.1UT TO ELEV. -i IT D,DR . i ! 8°4 FROM PREVIOUS > (+) -6 ..........1 1 i . ., \-,,TO N:E.XT CONTROL PANEL . ; t.,... k M-142 , ! La p 1 ADDRESSABLE DEVICE >Dt_Ti)1 IN I I -)( ADDRESSABLE i i Fi C'VATOR CAR FAN --.1 f 1 6 DR --) DEVI ',E ER2 (20 AMPERE TRP F USES) I . (4 L-MOUNT THESE DEVICES BY THE BREAKER PANEL / FUSED F..);SOON N EC I FoR 5 ce TYPICAL ELEVATOR RECALL/SHUNT TRIP & ELEVATOR WARNING LIGHT WIRING DETAIL L-MU NT WITHIN 31-0" OF ELEV.A.1"0:' UGH TS (LOCATED IN ELEVATOR EQUIP, ROOM(S)) ELEVATOR CONTROL PANEL. I ____ _______. _ . . ....__________ _ _____ -- -- ___ _ __......... --- ...._...... .....___ _ ROOF FLOOR =IRE ALARM PLA\ • SCALE: 1/8 '' = N-- SEE TYPICAL,, ELEVATOR,. „....„„ WARNING'' DITEK RECOMMENDS A LICENSED ELECTRICIAN RECALL/SHUNT TRIP INS T ALL Jr HE_D I K_12,:ia.,.HW AND ELEVATOR WARNING LIGHT f,,, --ti; — _.1.;...._;„,L__,......... ,.....q„,_ ::: L:; 1,,,,, lal •ILI ,, t.,.: ,_.17.......„..„•••n\\ fr.,. E .^ I. a,„ :,• Ki \ ■ P‹ DITEK UNITS SHOULD BE CONNECTED TO THE LOAD (p/n SG-32SK1-SC) WIRING DETAIL THIS SHEET i v --,i 1 SIDE OF THE FUSE OR CIRCUIT BREAKER, i H4-1 H4-8 r 1 j , \ : d \i/ i H4 WP H44.... . H4/ .::::::„......,„.„,,,,,.....„....„.,:::„„:„........„...:::,..,,„„,„„,,,,,,,......„:-. k. ,,:--------WP ' 1 FLOOR J-BOX WP _ELO_L-H4 IA, 75 H4-7 47K OHM EOL, ---T,==.2---, 1 I 1 D y ?i la i i -■1 -----' ------' A 1 c , , I i :VP n ), _ , i :: • -,.-- m ,, • - .... :,.....„,...., ) ,... . ., ., •,.,..,...,,,7,„„4, 1 , / 3 g \ j 13'` ! i \ :: h r 751)-x triwp BLK, L GREEN WIRE TO GROUNa : : ,.;_:....,.,...:::._,-----. ,1„-... ....—,-----..._ :: • 1 \ ,< 15 -- i DTK GRN. 2 WHITE WIRE TO NEUTRAL t4-11 : : \ I, : 1 BEDROOM I .._ .. 1 Hil \/ ilt-4 I , / .0 1 ii / 1 1 1 i t--:c,_•4 T:11 WHT, 120 HW 3, Bi ACK WIRE TO PHASE, N.O, DRY CONTACT i 1 t.---=-/ il :1 ../ \ , 1 ----J BEDROOM 0 : -:',. ' D ,,,, , , , , it.----' ../ \ .r--- L_____ WEATHERPROOF trd , J., i „.,-- ) BEDROOM .. / \ :; • BEDROOM % '\\ I/ '' ..L .• •5;,::, - ,,/ 1> \:: : . 1 . .,::!..: •iii Lt-r--1-'-'I--- 0-,r---- ON , ri DOWN TO 3RD, ,. ,C1 1 1 5.1 .t, \ • , ,_'--i , GROUND 1Z C) PULL STATION - t...-ii- &TIMOR PULL \'' - 1 _ . _....._.= ':-.. - • 1 ..: r.0 .,...,c,.... ......_, ul 5 6.,-s• , r-. T- -TnArr-- __ z _,-,../ ..,,,..,„..... ;1 t?„, ,,,,,,,,,";-, -----,-"--sr:- --n--<- I ”' \ Op t BEDROOM 1 - I :::..„.n,...4 I 4 \ \ 17 N i . 1.......... BEDROOM 1-.- A L-..; H. 70 ,, .., _ ._, • H4_, ii \ ... ,. a „......„ ......._, .,.,. „,,.._ 1 :: : :: . ,, ; ......_ .„4--1 , I / { - ' Li - 1 1 .!:-...7s\ 1.,-'1 ^". 4*. .t.:,4 : . .,:: ..--. ,','N o''''',,,.." 1 1 . H cyl CI S<C z SYBOL= HP ' II 8 7 } :i 0 0 0 • it . & k.--,t • KITCHEN - 11 ,-..„,:..„ r _al----3 KITCHEN • c '; ' , „.. - i i . ,,$I"..1 k KITCHEN ' --, - I :-.---1 I !! I : 1 - -1 I / <6 1 ,... - \ m , ________i :-.7' : 0---H4 ..1 CD 0 11 alePUTMCIDULEI (p/n SIGA-CT1) Ct. . k 7 . „.- ,,-, ,, , , I --7 ,,Nj-- : ,---, --BATI-4-0. %- , , , z pi nc ,,,- , D (i) -`:-E5 . ......r , - - -; -<,.::,,, \-,..,,,j ,I: ' . : cp 1.,_ CAUTIONt MEASURE ALL VOLTAGES TO INSURE APPLIED VOLTAGE DOES I: . 814,4.-CT I I: 0 ,,,', . ."'" , BATH-,- '' BATH rii ' ' - BAT 6 ii ir.-) • ?..i ' )i -•I L, I..4 '1 ,.„, ..., 111, \I"' -;-.: •t:' :: // i' H4-404--; , ---%._ 1 1 ii \ • in cx, NOTEXCEED THE VOLTAGE RATING OF THE UNIT. IMPROPER II 0 e...., p4: CTI i _ I, ..?e• . ., ../-F-1-MECH ---- -!---MECH 14 .14.--.5 BATH ' I "------. ,.; i.-- INSTALLATION VOIDS THE WARRANTY, PLEASE ALLOW THE SURGE p - al.... i:,-.: .4) • 0.„„4-: i i. vi B7AT!. li rr 7 4:1 L, ) : : I ,)---- r .1n, : , :., 7, : . - PROTECTOR REACTION TIME BY PROVIDING 3-5 FEET WIRE BETWEEN 4 3 2 1 tt-1 ,, 11`-. Z g i: H4-3 ' ._' -, :; .:.> ._. II H4-, .z. ,: -„, i , _ H4 ' 7: THE DTK-120 HW UNIT AND THE EQUIPMENT TO BE PROTECTED, . i \------> - BATH s.--- , — D 4 0 Z > '`-'cTi•chccP ALSO, TI WIRE DISTANCE FROM THE SURGE PROTECTOR TO li AIBMBEU, D- il 1 zri k, LIVING IMECH 1 / :: 1 1 ii I i 1 , : I „,,,,,, 1 V) 0 -.1 t6".- 15 l'--.ci‘.. L•rE3 PROTECTED EQUIPMENT MUST BE GREATER THAN THE WIRE DISTANCE STAMM RASE "; ROOM : i LIVING 11 11 \\ (.:d IMEOH g A .: . _};) rt le -,,,, -,, 1— t- =-- •.•,,,,,,,, ,,,r----4-tH---0 „ LIVING L:., _ 4:E FROM THE SURGE PROTECTOR TO GROUNa D- D - n I CAT.110. SIGA-SISq BLK (-) H4 • y '., :: ) LIVING 1 I , L.--.....J „, . ,,. „' /:,., - (+) DATA IN I DATA OUT • ii LI 1 -./ 1,-,,..- r.---- 1 t . \, -..1 ROOM 's -1-t .-U •c-..).¢=....... \: < ;.,.., KITE! CONNECT GREEN WIRE TO MECHANICAL GROUND FIRST; THEN WHITE, DATA IN(+) - I DATA OUT s, RED (.±) . • . ii,.../ ... AND BLACK WIRES LAST. (-) > . v >(-) ...-1 i • L —I o H-: L., ,., _ ....,..., I „,-,._,...,..,... ,• : .... , "SIGA—CT1" MONITOR MODULE TO SMOKE OR HEAT DETECTOR BASE : 1 - MASTER BEDROOM 1 7 MASTER BEDROOM 1.! : MASTER BEDROOM 1 ........... Z ,,._. DTK-120 Pd 111-RGE PRH-ECTOR INSTALLATION DETAIL WEATHERPROOF PULL STATION N.T.S. i BALCONY ..._.,.., N : 1 BALCONY I_ > z til 1 BALCONY I \ I 111 'N 7 MASTER BEDROOM --- U I / BALCONY z D '21 ,D -•=c1 N.L >. N.T.S. i \ : \ , I ill ii 11 _______ _____ _ - . ti r- .<• --=-=• ' m - ,-.--il 0 .... :... . --.=.:4-,a•-• . ......-:-„„. ..--:;<::;:::===6-16-v-azz,. .7a,_,<-' ,, 0 P LC1C ICZ.9°3 [ET 4T- FLOOR FIRE ALARM PLAN o LL. .----,A-----c-,-, (MAX OUTPUT ----- 2 AMPS) 1) SCALE: 1/8 " = 1'-0" • 0 o „....,...,..... • ----'(.MAX OUTPUT = 1 AMP) TD DEDICATED TO DEDICATED ••••., - HP i. 2n vAn —, — tL r„, :-. i 120VAC ASWP-2475W-FR ASWP-2475W-FR 7 PHONE LINE #1 I 'Z' TYPE CABLE --.- -'Z' TYPE CABLE ITIORN/STOBE INPUT HORN/STROBE HORN/STROBE i. I „, 1 - ---- ) 0 TO TELEPHONE , k)>E(1‘'''P II. ar-2TKI 1-0 h•'M <For I VOLTAGE ONLY) A 1 ,(4) A CS! <-0 A 0-> i 1.0K-1 a BACKBOARD I HP ,--,., Y. I PHONE LINE #2 1- I 1111 1 II 1,- ,--,c-..-•>in I TELEPHONE CABLES 47K OHM F--LI1W SW, TAMPER SW, 47K OHM I- FROM BPS < 1 VP I _ 1 _ (2) 4-PAIR #24 AVG. EL,L, E.O.L. L-:- , ' ''‘ (-) • - • 0(----> !''At i iii , , , ,... A I H# H# H# =CI-,..._,Cr,•4:4- 0.00000000000000000 ,,b000000 MI_ ANN NO C (VC C NO C NOC NO F/U + - + - r g ezx Rx B+ B- A+A- B+ B- A+A- ...-71.11-M117.. .. N M 1- >- >. ),- ),- SMK. RS485 PWR. R232 - NAC I NAC 2 1/41 k‘€1 0 0 0 0..'. 8 B P S 8 71v_ ...,,,. ...:„ „ :: :, " :: „ ....._....„, 8 7 6 5 H W M i (D- i! (p/n SIGA-WTM) I FIRST DEVICE MIZ-24S-W HORN 1 AST • 4 < < ‹ T B1 o o o HORN/STROBE WIRING DETAIL I . . c,..... , d d ACC. TB1 .. . _... w i w w PwR. I Er cz x ce C) 181 PUIRPIRPIR 0 0 1 II L N.T.S.T El RED (+\--) (.1) . D- DATA (._.) Fl I I I I II • : I = 10 AMP 250V C U S 1.1 AC POWER SWI SELECTION p 120/240VAC El IN C - .t„1„; , .riii II RED (4) 717.417±-'crs.,1.::...1...H...'..i..........!..,1 SYMBOL (TYP. ) ''' > (+) / 1 I AC POW DATA OUT D ‹ SLIC FUSE V > (-) I--1 k DLD : REMOTE POWER SUPPLY BLK, (-) BLK, (-) 0 cp : 1 PS6 i , OUT TREI MO- AC WHEELOCK 4PS-12/24-8MP TYPICAL WIRING DETAIL CLASS B CIRCUIT, Z rY 1 < 0 - 1 1 DB RUTI 09 FI D13 um 015 Np2 WIRING FROM MODULE TO E LA .c 0 D14 ouT3 DI S ts. D71opowER SUPPLY DC I I N I gfi 018 otn-4 019 BATT FLOW AND TAMPER SWITCHES 0 cY : n SW4, DC POWER OUT I I =PUTT larSt/C WHEEICCK sac 7,4 SW2 SW EVIEELCOC MC ra Ri,SELECTION 12Vde OR 24Vdc MTS. 0 z co m <E -,-,,- II I •PPM§ Elm- NM= • • ■,..4.0 4 Z '.'fiskpattv.:'.“4/Msw5 Byis i .: ; . ga xi La i---1 > _. . Li T B2 TB2 0 MIT SEIECT Pi1U1! ON OFF ON OFT SELECT LI j- 0 L1 Z 0 120VAC BATT PWR NC .3 •i B 2 8 OUT IN LOOP •I U •tE •GE 0_ I.1.1 Li CC a_ i 3 + - + - A+A-B+B- MT lil ' BATT Z p21 E0) PI 4r I'M I n00 O 00000 000000 I-1 ‘7,/ ,..,.? ,... 1....J sw7E _I \ hi 1,1 070n MICRO ' CEILING LINE u 1- r__ : rin...„FAILT NO LESS THAN 6" , NO LESS THAN 6" NO LESS THAN 6" LI D -----/ CI --- ir cii,ss/./B i f i DBLK (-) cy Z P8 la 4230 SELECTM iiiyi 0- , REV. SWITCHES SN9 'l f ,.,_, trio 0 n 0 . TO ANALOG TOUT OUT2 OUTS OUT4 II DATA OUT : '..: •'`.- Pa- RET1- DRY1 1N2- RET2- DRY2 .,_ At 13, f.7\2. LI DEVICES IN1+ it ET1,1- C NC IN2t ET2-1-= C 16 ' ....- + rig- + pm- + - I NO 1 C NC 161 ;....., LI o U o > L11 > RED (+) TB4 8 0 g: $ .0- 11114 POI 7 -17417-77, . gja; 0 WO 0 0 4 0 0 < < 0 - Iii Wild WWII W6/ "--"i--"-"- p=/ HORN/STROBE 'A STROBE MINI-HORN < T85 1B QV -al Ce }---- — 10K (... c) - > 1 CO '--4 FACP BPS ILI --I CO In rn i 2-I MANUAL PULL STATION 1---1 C-H4 a -- - — -- --.- > V) '--.1 (-) > 2i _j AUX. POWER OUT 0 —1 85" A.F.F. TO CTR. c (4 LT i • 0 i 1,-1::: (-0 > 0--H3 x) ? z SUGGESTED MOUNTING (.1) o_ ci >- z 1- -1 It."-/.. ■ OF BOX ID ? 0 80 MIN. 80 MIN. 90 MIN. }- d d -- ...... -1 ‹ 3 3 • ejr----35 TO-7."-----75 H2 2 70 MOUNT 413" A.F.F. R P A TEwLEVRATINOGN MDGE, THATSI,LDsET: ± ,..... .4,. , - a TO TOP OF HGHEST CONTROL DESCRIPTION • e med 48 BUTTONS OF PANEL. FIRE ALARM rs,\_.....r..,,,,, --\A---1-n v 0----HI BA--: )V ,.. \ 1 in r N I .,, - -ro," Lqi T:..K I ,(1_, , ,, „:: L ,: V) , MOUNT 48" A.F.F. TO CTIR. OF CABINET FOR SUGGESTED MOUNTING / SYSTEM . „....„. \ 4TH & ROOF FACP . ' FINISHED FLOOR LINE w w 'a Division p2 H2'Gio.9eNooBErfg:Ricaa9:cwiki i'liocn3neod.v in3Asl10eev3NeS: --.„ 7-, \ / ,--N ,\ :/...., 7-1 ,,--, ,...„, \,...,„ \„, ,, „ , i ..,,,..) I ......., F1_OOR PLANS; NOTE (FOR NON-SLEEPING ROOMS): MOUNT HORN/STROBE, STROBE OR HORN . FIRE ALARM PANEL WIRING DETAIL FIR 7 _ ALARM WIRING DIAGRAV ACCORDING TO LOWEST WALL MOUNTED EQUIPM=NT ELEVATION MOUNTING - EIG- TS DETAIL Licensee Name: 13 SHEET NUM JOB NUM, (NOT TO SCALD N.T.S. FA.02 S06-053 Signature: __ .____ / 02 OF 03 _ ___ _ ___ _____ _...________ ___ ___ ___ __..____ ____, ____ ______.__ . ____________ . --- ------ _ _ , _______._ _______ __ _ ..,■_ Sound xrat rn:no:Qv u.jas79h's;2:70A3 5:310400 194.os,In'c.