HomeMy Public PortalAbout07-0195 Evans & Daly N
CITY OF TYBEE ISLAND
BUILDING PERMIT
DATE ISSUED: 04 -30 -2007 PERMIT #: 070195
WORK DESCRIPTION: DRYWALL, CABINETS, FLOOR
WORK LOCATION: 1608 JONES AVE 2
OWNER NAME ROBERT & MICHAE EVANS & DAILY
ADDRESS 11 E LATHROP
CITY, ST, ZIP SAVANNAH GA 31415
PHONE NUMBER 912- 691 -2102
CONTRACTOR NAME ROBERT & MICHAE EVANS & DAILY
ADDRESS 11 E LATHROP
CITY STATE ZIP SAVANNAH GA 31415
FLOOD ZONE
BUILDING VALUATION
SQUARE FOOTAGE
OCCUPANCY TYPE P
TOTAL FEE'S CHARGED $ 95.00
PROPERTY IDENTIFICATION #
PROJECT VALUATION $10,000.00
TOTAL BALANCE DUE: $ 95.00
It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire,
soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including
all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be
approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction
covered by this permit.
This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted
work will he stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided
unless work has begun within six months of the date of issuance.
Signature of Building Inspector or Authorized Agent: _ A
P. O. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328
(912) 786-4573 - FAX (912) 786 -5737
www.cityoftybee.org
LAW OFFICES
CALLAWAY, BRAUN, RIDDLE & HUGHES P.C.
A PROF£881GNAt CORPORATION
TIMOTHY F. CALLAWAY, (It 301 WEST CONGRESS STREET REPLY TO:
DANA F. BRAUN SAVANNAH, GEORGIA 31401 POST OFFICE BOX 9150
R. KRANNERT RIDDLE - ...... SAVANNAH, GEORa4
EDWARD M. HUGHES TELEPHONE (9121 2382760
ANNE ALLEN WESTBROOK FACSIMILE 1912) 238 2757 Of Counsel:
MONICA 9. PATEL Stanley E, Harris, Jr.
March 27, 2006 Voice Mail Extension #3011
nn l - Bhughes@cbrhiaw.aom
VIA FACSIMILE ONLY
Dee Anderson
City of Tybee Island, Georgia C O �y
P.Q. Box 2749
Tybee Island, GA 31328 -2749
RE: Condominium Conversions
Our File No. 510
Dear Dee:
You and I have previously communicated about our procedures dealing with conversions
of apartments into condominiums. I am enclosing an additional letter dated March 7, 2006 that I
received from Attorney Mark Shawe along with a copy of O.C.G.A. § 44 -3 -114.
I think under the circumstances here, where there is not going to be any alteration of the
existing structure, under our present ordinance, we do not have any involvement in the
conversion to a condominium project. A nonconforming use for other issues such as parking or
firewalls would continue to be just that, that is, a nonconforming use.
In effect, condominiums and apartments are virtually identical in code requirements and
any conversion of existing apartments into condominiums is not regulated by our code and under
O.C.G_A. § 44 -3 -114 probably could not be under most circumstances.
Please call if you have any questions or comments. With kindest regards, I am
Very truly yours,
/ r- --.--y
Edward M. Hughes
EMFIlbb
Enclosures
cc: Mayor and Council of the
City of Tybee Island, Georgia (via facsimile)
MAR -07 -2006 TUE 04:28 P11 FAX NO p, 03
WEINER, SHE AROUSE, vain, GREEN13ERG & SRAWI ,
March 7, 2006
Pa1 2
As always, 1 appreciate your ti«itc and input,
WW1 best rognrds, I am
�
Sincerely yours
F J
Mark T. Shawe
For the Firm
AM'T'S /pjp
;I d nw e:r.ri; orni unow phd-• a,ohco.t. IN,9,, u i dw:
Municipal Code
Section 4 -2 -24 Amendments and modifications to fire prevention code.
The following provisions shall amend and modify the provisions of the fire prevention code and, if in
conflict with the provisions of the fire prevention code, shall control and prevail:
1. No building or structure shall be erected hereafter closer than ten (10) feet (measured from the
closest point of the structure footprint to the property line) to the adjacent property line except the
following:
a) An accessory building of all metal construction not more than one story n height
nor more than six hundred (600) square feet in area, located on the same lot with
a dwelling, provided that building shall be placed at least five (5) feet from any
lot line,
b) A building so constructed that the exterior walls that adjoin adjacent property be
built to form a fire wall or have a full sprinkler system installed.
1. The walls that separate units in any building constructed with two (2) or more units that may be sold
as individual units, such as in condominiums, shall be fire walls.
2. Where more than one building or structure is built on a single lot, there shall be a minimum distance
often (1 0) feet between structures unless separated by fire walls.
3. Any building erected with the purpose of accommodating more than one commercial establishment
shall have fire walls to separate each establishment unit.
4. Wood shingles, treated or untreated, shall not be accepted as an approved material for a roof
covering. All other roofing shall be classified a class A, class B or class C under the test
specifications of Underwriter's Laboratories, Inc,
5. Any person or persons owning or operating business or commercial buildings shall be governed by
the standards for the installation of portable fire extinguisher found in NFPA No. 10. (Code 1970, 7-
4)(Ord.1996- 23;10/10/96)
6. Common walls, that separate two or more units or two or more in stories in a multi -unit structure,
shall be fire walls and any deviation from this requirement shall require a petition for variance before
the Tybee Island Planning Commission and City Council.
7. In all multifamily structures of two or more units, each dwelling unit shall be separated by either:
is A firewall as defined in the latest edition of SBCCI as meeting four -hour resistance with
protective openings of three -hour resistance (Table 600) and which shall extend from the foundation
and through the roof, unless non - combustible roofing materials are used forty (40') feet to each side
of the wall, thus by its construction enabling the collapse of a structure on either side of the wall
without collapse of the wall itself. or
Each unit shall be fully sprinkled by a system conforming to the Southern Building Code
/ Congress International and installed by a firm holding a valid Georgia State Competency
Certificate.
8. In those areas designated as V -Zones of NFIPA maps published by the Federal Emergency
Management Agency, only "ii" above shall be permitted. (ord. 1993- 5 ;Oct.14 /93)(Ord 1996-
22;10/10/96) (Ord. 1998 -04; 2/12/98)
Page 9 of 22
_ ...._ .._.„ ..___ __.
. CITY OF TYBEE ISLAND, GEORGIA
APPLICATION FOR BUILDING PERMIT
‘,-- -
-)
Location: 't ‘1/40 0 . ' • K )01\) I.' TkOta,_ I PIN #
NAME ADDRESS TELEPHONE
- 1 - '7 — --T. "-----1
- s.t i.,1-= ([ or2.,..(4 I . z 1 L
- ,
-; ,
-- u ,
Architect
N)I A
--1 1
or Engineer
Building az tE.A-- . > , ) ) )
_Contractor Iv\ )r_I-kr1C,L., Pty t-le.,
(Check all that apply)
{]'Repair 0 Residential El Footprint Changes
0- Renovation 0 Single Family E__ Discovery
0 Minor Addition 0 Duplex Ti Demolition
0 Substantial Addition a .ulti-Family 7
0 Other 0 Commercial
Details of Project: f05 ) ..a_ei 0-.) (re.),
i — 1 -
.
Estimated Cost of Construction: $ I 0
Construction Type _ (Enter appropriate number)
(1) Wood Frame (4) Masonry (6) Other (please specify)
(2) Wood & Masonry (5) Steel & Masonry
(3) Brick Veneer
Proposed use:
Remarks:
ATTACH A COPY OF THE CERTIFIED ELEVATION SURVEY OF LOT and complete the
following information based on the construction drawings and site plan:
# Units I # Bedrooms I # Bathrooms i
Lot Area Living space (total sq. if) .57)00
# Off-street parking spaces P
Trees located & listed on site plan
Access:
Driveway __ (ft.) With culvert? With swale?
Setbacks: Front Rear Sides (L) __ (R)
# Stories Height . Vertical distance measured from the average adjacent
_
grade of the building to the extreme high point of the building, exclusive of chimneys, heating
units, ventilation ducts, air conditioning units, elevators, and similar appurtances-
• „ I CYO 7Jr-I, fl C K.JeL
During construction:
On-site restroom facilities will be provided through
On-site waste and debris containers will be provided by
Construction debris will be disposed by by means of
I understand that I must comply with zoning. flood darnaee control. building, fire, shore
protections and wetlands ordinances, FEMA regulations and all applicable codes and regulations.
I understand that the lot must be staked out and that the stakes will be inspected to ensure that the
setback reouirements are met. I understand also that a certified plot plan showing elevation must
be attached to this application and that an as-built elevation certification is due as soon as the
habitable floor level is established. Drainage: I realize that I must ensure the adequacy of
drainage of this property so that surrounding property is in no way adversely affected. I accept
responsibility for any corrective action that may be necessary to restore drainage impaired by this
permitted construction.
Date: -41V tr"' Signature of Applicant: Vc)
Note: A permit nonnally takes 7 to 10 days to nrocess,
The following is to be completed by City personnel:
Zoning certification NF[P Flood Zone
Approved rezoning/variance?
Street address and number: New Existing
Is it in compliance with City map?
If not, has street name and/or number been reported to MPC?
FEMA Certification attached
State Energy Code Affidavit attached
Utilities and Public Works:
Describe any unusual finding(s)
Access to building site
Distance to water main tap site
Distance to sewer stub site _
Water meter size
Storm drainage
Approvals: Signature Date FEES
Zoning Administrator Permit
. oc,
Code Enforcement Officer Inspections 30
Water/Sewer Water Tap
Storm/Drainage Sewer Stub
Inspections Aid to Const.
City Manager
TOTAL
TOTAL P. 02