HomeMy Public PortalAbout1984-011r Resolution No. CITY OF MEDINA Resolution Approving the Alignment and plans and specifications of the Medina Interceptor within the City of MEDINA Whereas, the Metropolitan Waste Control Commission plans to construct a major sanitary sewer interceptor in the City of MEDINA and Ighereas, the a lignment of this major Interceptor, has been reviewed by the City .of MEDINA , and Whereas, the plans and specifications for the interceptor have also been reviewed by the City of MEDINA Now therefore, Be It Resolved that the MEDINA City Council hereby approves the alignment and the plans and specifications for the Medina Interceptor. The motion for adoption of the foregoing resolution was duly made by and seconded by and upon vote being thereon, t�ol owing voted in favor thereof: and the following voted against the same: whereupon said resolution was G" m eri/ Date Clerk -Treasurer taken PROJECT DESIGN SUMMARY PROJECT: Medina Interceptor M.W.C.C. Project No. 83-59 DATE: May 10, 1983 PREPARED BY: Comstock & Davis, Inc. 1446 County Road J Minneapolis, Minnesota 55432 John E. Bearden, P.E. Design Conditions The flow to pass through the Medina Interceptor has been projected in the "Southwest Facility Planning Study, 201 Facilities Plan", dated June 1980. The design flows from Table II - 10, page II-15 is reprinted below: Average Flow Peak Hourly Flow Design Flows: Year (MGD) (MGD) 1980 0.08 0.32 1990 0.16 0.61 2000 0.20 0.76 2020 0.28 1.05 For the year of 1981, the following flows were reported in the "Medina W.W.T.P. Evaluation", prepared by the M.W.C.C. November 30, 1982. Basis Of Design Year of 1981 Average Annual Flow Minimum Month - January Peak Month - July Table 1 0.104 MGD 0.075 MGD 0,157 NGD Basis Of Design For The Medina Interceptor Average Annual Flow Peak Month 200% of Average Month Peak Hourly Flow 375% of Average Month 0.28 MGD 0.56 MGD 1.05 MGD Design Lift Station: • Cast In Place Concrete, Top Elevation 980'-0"* • Three Pumps - Two Pumps Running To Have Pumping Capacity Of 1.05 MGD Through 10 Inch Forcemain; C=120 • Stand By Power To Be Provided By Existing Portable Generator. Manual Transfer Switch And Generator Outlets Provided. * "Flood Hazard Analysis Elm and Rosa Creeks", By U.S.D.A. and S.C.S., Dated September 1975. Section 125 at Lift Station 100 Year Flood Elevation 977.1 is being Revised By Elm Creek Water Shed District To Elevation 979.2. Forcemain: • Size: 10 Inch Diameter • Length: 11,650 L.F. Design Velocity: 1.05 MGD, V=3.0 f.p.s. • Flow: Minimum Rate Old Pipe, One Pump, C=100, 550 gpm, V=2.26 f.p.s. Maximum Rate: New Pipe, Three Pumps, C=140, 870 gpm, V=3.57 f.p.s. Gravity Sewer: Size: 12 Inch Diameter • Length: 6,650 L.F. • Slope: 0.40 to 0.48% • Capacity n=0.013, 1015 to 1112 gpm • Capacity n=0.012, 1100 to 1205 gpm 4 . i .1„,-...ti''',,"!;`• • ... L -.........„„,e,..-,-, ....„7.3...r...... . „..........,/ ••,..-..„, i.:. :•:;,! -.... ....0 __: • ,. -..-...:-;,, ., ». 44tii •••:-.---,.... .....1., •••• _ -,-; . 7_ 1r faii, . ................ .e. ....... 0 ,.. .... . ...trir....i _ L • --.).. .... ,., ....... • ..... ....„, .................. . ........ ............. / givis.• . . ...... .;:z--.....;,-;:„.....,......., ...„...» _...!.. • -,....", 4„,.,.., • .,..,.....?..!.t,. ... .„............ .............. ............................... ............ ...---".......„....„ i .......... .1,........_,,,.......... r.” ..... .. . --• s 4, sm 4 WWI! • 16401014. MONINIMINIONISINSOMISNOri