Resolution Approving the Alignment and plans and specifications
of the Medina Interceptor within the City of MEDINA
Whereas, the Metropolitan Waste Control Commission plans
to construct a major sanitary sewer interceptor in the City of
MEDINA and
Ighereas, the a lignment of this major Interceptor, has been
reviewed by the City .of MEDINA , and
Whereas, the plans and specifications for the interceptor
have also been reviewed by the City of MEDINA
Now therefore, Be It Resolved that the MEDINA
City Council hereby approves the alignment and the plans and
specifications for the Medina Interceptor.
The motion for adoption of the foregoing resolution was
duly made by and seconded by
and upon vote being
thereon, t�ol owing voted in favor thereof:
and the following voted against the same:
whereupon said resolution was
G" m eri/
Date
Clerk -Treasurer
taken
PROJECT DESIGN SUMMARY
PROJECT: Medina Interceptor
M.W.C.C. Project No. 83-59
DATE: May 10, 1983
PREPARED BY: Comstock & Davis, Inc.
1446 County Road J
Minneapolis, Minnesota 55432
John E. Bearden, P.E.
Design Conditions
The flow to pass through the Medina Interceptor has been projected in the
"Southwest Facility Planning Study, 201 Facilities Plan", dated June 1980.
The design flows from Table II - 10, page II-15 is reprinted below:
Average Flow Peak Hourly Flow
Design Flows: Year (MGD) (MGD)
1980 0.08 0.32
1990 0.16 0.61
2000 0.20 0.76
2020 0.28 1.05
For the year of 1981, the following flows were reported in the "Medina W.W.T.P.
Evaluation", prepared by the M.W.C.C. November 30, 1982.
Basis Of Design
Year of 1981
Average Annual Flow
Minimum Month - January
Peak Month - July
Table 1
0.104 MGD
0.075 MGD
0,157 NGD
Basis Of Design For The Medina Interceptor
Average Annual Flow
Peak Month 200% of Average Month
Peak Hourly Flow 375% of Average Month
0.28 MGD
0.56 MGD
1.05 MGD
Design
Lift Station:
• Cast In Place Concrete, Top Elevation 980'-0"*
• Three Pumps - Two Pumps Running To Have Pumping Capacity Of
1.05 MGD Through 10 Inch Forcemain; C=120
• Stand By Power To Be Provided By Existing Portable Generator.
Manual Transfer Switch And Generator Outlets Provided.
* "Flood Hazard Analysis Elm and Rosa Creeks", By U.S.D.A. and
S.C.S., Dated September 1975. Section 125 at Lift Station
100 Year Flood Elevation 977.1 is being Revised By Elm Creek
Water Shed District To Elevation 979.2.
Forcemain:
• Size: 10 Inch Diameter
• Length: 11,650 L.F.
Design Velocity: 1.05 MGD, V=3.0 f.p.s.
• Flow: Minimum Rate Old Pipe, One Pump, C=100, 550 gpm, V=2.26 f.p.s.
Maximum Rate: New Pipe, Three Pumps, C=140, 870 gpm, V=3.57 f.p.s.
Gravity Sewer:
Size: 12 Inch Diameter
• Length: 6,650 L.F.
• Slope: 0.40 to 0.48%
• Capacity n=0.013, 1015 to 1112 gpm
• Capacity n=0.012, 1100 to 1205 gpm
4 . i
.1„,-...ti''',,"!;`• • ...
L
-.........„„,e,..-,-, ....„7.3...r...... . „..........,/
••,..-..„, i.:. :•:;,!
-....
....0
__:
• ,. -..-...:-;,,
., ».
44tii
•••:-.---,.... .....1.,
•••• _ -,-; . 7_
1r faii, . ................
.e. ....... 0
,..
....
. ...trir....i _ L
•
--.).. ....
,., .......
• .....
....„, ..................
. ........ .............
/
givis.•
. . ...... .;:z--.....;,-;:„.....,.......,
...„...» _...!.. • -,....", 4„,.,.., • .,..,.....?..!.t,. ... .„............ ..............
...............................
............ ...---".......„....„ i .......... .1,........_,,,..........
r.”
..... .. . --•
s 4, sm
4
WWI! •
16401014.
MONINIMINIONISINSOMISNOri