Loading...
HomeMy Public PortalAbout06-11-2013MEDINA PLANNING COMMISSION AGENDA TUESDAY, JUNE 11, 2013 7:00 P.M. CITY HALL (2052 County Road 24) 1. Call to Order 2. Public Comments on items not on the agenda 3. Update from City Council proceedings 4. Planning Department Report 5. Approval of May 14, 2013 draft Planning Commission minutes. 6. Mono a Hol i„gs, T L C pm 01 1 8 73_22-0006 (ens of County Road 116, south of Hackamore Road) Preliminary Plat for 13 lot subdivision on 10 acres (5.72 buildable acres) and Rezoning to the R1 Single Family zoning district. PUBLIC HEARING TO BE HELD ON FUTURE DATE 7. Complete Eye Care of Medina — 170 Westfalen Trail (PID 12-118- 23-41-0117) — Site Plan Review for construction of new commercial building 8. Ned Sorley — 4200 Hillview Lane (PID 06-118-23-41-0002) — Comprehensive Plan Amendment to extend the Metropolitan Urban Service Area to include property to permit existing lot to connect to municipal sanitary sewer system 9. Council Meeting Schedule 10. Adjourn POSTED IN CITY HALL JUNE 7, 2013 MEMORANDUM TO: Mayor Weir and Members of the City Council FROM: Dusty Finke, City Planner; through City Administrator Scott Johnson DATE: May 30, 2013 SUBJ: Planning Department Updates June 4, 2013 City Council Meeting Ordinance Updates A) Lot Frontage, Flag Lots, Driveway Regulations — staff began work on an ordinance related to these subjects, which originally was a 2012 goal, but was deferred as other ordinances were determined to be of higher priority. The Planning Commission reviewed at the April and May meetings and recommended approval of the ordinance. Staff intends to present to the Council at the June 4 meeting. Land Use Application Reviews A) Morrison Lot Split and Variance — Truxtun and Adrienne Morrison have requested to subdivide their 18 acres at 1525 Hunter Drive into two lots. The applicant also requested a variance from the required road width standards of the subdivision ordinance, but has since withdrawn this request. The Planning Commission held a public hearing at the April 9 and May 14 meetings and recommended approval. The Council reviewed at the May 21 meeting and directed staff to prepare a resolution of approval. The resolution will be presented at the June 4 meeting. B) Fenske/Cole Variance Request — 2959 Lakeshore Avenue — Sandra Fenske and Randy Cole have requested a variance from the setback from Lake Independence to construct a house addition in the location of an existing deck on their home. A lake setback variance was granted in 1999 for the deck, but staff determined that the two-story (+ walkout) addition in the same location and an additional deck proposed by the applicant was an intensification and could only be constructed if a new variance is granted. The Planning Commission held a public hearing at the May 21 meeting, and recommended approval, but only if the applicant reduces hardcover on the property below existing conditions. Staff intends to present the request at the June 4 meeting. C) Complete Eye Care Site Plan Review —170 Westfalen Trail — Dr. Wesley has requested a site plan review for the construction of a new building to house Medina Eye Care next to West Financial at Sioux Drive and Highway 55. Staff is reviewing the information, which will be scheduled for a hearing at the Planning Commission, potentially at the June 11 meeting. D) Sorley Comp Plan Amendment — 4200 Hillview — The property owner has requested a Comprehensive Plan Amendment to add their 6 acre property to the Metropolitan Urban Service Area (MUSA) so that they can connect to the City of Loretto's sewer system instead of replacing a septic system on their property. Staff is reviewing the information, which will be scheduled for a hearing at the Planning Commission, potentially at the June 11 meeting. E) Fawn Meadows subdivision — east of CR 116, north of Medina Lake Drive — Money Tree, LLC has requested a preliminary plat and rezoning for the development of the 10 acres (5.72 net acres) immediately north of the Toll Brothers Reserve of Medina project. Staff is conducting a preliminary review and the item will be scheduled for a Public Hearing when complete. F) Kunin/Anderson Lot Rearrangement Easement Vacation — 855 Medina Road — the property owners have requested to rearrange lot lines to add two acres of property to 855 Medina Road. Planning Department Update Page 1 of 2 June 4, 2013 City Council Meeting The applicant also requests the vacation of drainage and utility easements adjacent to the lot line proposed to be adjusted. Staff is conducting a preliminary review and the item will be presented when complete. G) Three Rivers Park/Reimer Lot Rearrangement — the property owners have requested a lot rearrangement to allow a "land swap" of property which the Reimers own on the west side of Homestead Trail and which Three Rivers owns on the east side of Homestead Trail. The applicants do not wish to submit the deposit required by the City, and have not completely filled out the application forms. The item will be presented when complete for review. H) Johnson Lot Combination, Comp Plan Amendment and Rezoning — 2505 Willow Drive — The City Council approved of Dan and Jill Johnson's requested lot combination, CPA to change the future land use of three parcels of land from Rural Residential to Agriculture and rezoning of the property from Rural Residential to Agricultural Preserve at the May 21 meeting. Staff will work with the applicant to finalize conditions of approval. I) The Reserve of Medina Preliminary Plat — The City Council granted preliminary plat approval to Toll Brothers on May 21 for a 126 -lot single-family subdivision on the Gorman Farm property east of County Road 116 and south of Hackamore. The City will await an application for final plat. J) The Enclave at Brockton 3rd Addition — Lennar has requested approval to plat the "detached townhome" portion of the Enclave at Brockton. The Council approved a resolution at the May 7 meeting. Staff will assist the developer in finalizing the terms and conditions of approval before construction begins K) The Enclave at Medina 3rd Addition and 4th Addition — the City Council approved the final plat requests at the March 19 meeting. Staff is coordinating the conditions of approval before signing the plats and authorizing work to begin on the improvements. L) Fields of Medina West —1st Addn — north of Highway 55, east of Arrowhead — Mattamy Homes applied to final plat 34 of the 64 lots within the subdivision. The Council granted final plat approval at the April 16 meeting, and staff is working with the developer to finalize the conditions of approval before construction begins. Additional Projects A) Cable Expansion Priority — staff provided updated information for a meeting with Mediacom to discuss timing on expanding cable access in the community. B) Planning Commission Interviews — staff took part in interviews with Council Member Martin and Vice Chair Reid with applicants for open seat on the Planning Commission. The group will provide a recommendation to the City Council for appointment at the June 4 meeting. Planning Department Update Page 2 of 2 June 4, 2013 City Council Meeting 1 CITY OF MEDINA 2 PLANNING COMMISSION 3 DRAFT Meeting Minutes 4 Tuesday, May 14, 2013 5 6 1. Call to Order: Commissioner Charles Nolan called the meeting to order at 7:00 p.m. 7 8 Present: Planning Commissioners Robin Reid, Randy Foote, Charles Nolan and 9 Mark Osmanski 10 11 Absent: V. Reid and Kent Williams 12 13 Also Present: City Councilmember Kathleen Martin, City Planner Dusty Finke, Nate 14 Sparks of NAC and Planning Assistant Debra Peterson. 15 16 2. Public Comments on items not on the agenda 17 No public comments. 18 19 3. Update from City Council proceedings 20 Martin updated the Commission on recent activities and decisions by the City 21 Council. 22 23 4. Planning Department Report 24 Finke provided an update of upcoming Planning projects. 25 26 5. Approval of the April 9, 2013 Draft Planning Commission meeting minutes. 27 Motion by Foote, seconded by R. Reid, to approve the April 9, 2013 with one minor 28 change. Motion carried unanimously. (Absent: V. Reid and Kent Williams) 29 30 6. Public Hearing — Randy Cole & Sandra Fenske - 2959 Lakeshore Avenue - 31 Request for a Variance to the Setback Requirements from the Ordinary High 32 Water Line (OHWL) of Lake Independence for an addition and deck onto their 33 home (PID 18-118-23-23-0022). 34 Sparks presented request for a Variance to the OHWL setback requirements. He 35 explained the lot is approximately 7500 square feet in size. The applicant is 36 proposing a full addition with a narrow deck and stairs. The stairs extend out into the 37 yard currently and would be proposed to be less intrusive and would be parallel to the 38 deck and not towards the lake. In 1999 variances were granted to build a home on the 39 property to replace a cabin. The house was then built 25 feet from the road rather 40 than the 30 foot requirement, even though they weren't approved for the 25 foot 41 setback. Staff is not sure how this happened, though the front of the house appears to 42 be in line with the other homes along the lake. He said some consideration at the time 43 of construction may have been allowed, but staff is unsure. The lot currently exceeds 44 the allowable hard cover. Sparks further summarized the neighboring properties and 45 Variances granted along the lakeshore. 1 46 47 Sparks reviewed the Variance Criteria with the Commission and explained if the 48 Variance was granted as requested, it wouldn't change the character of the area. He 49 said lately the City has been looking closer at the impact of the local waters. He said 50 in this case, if the Commission were to consider approving the Variance staff would 51 recommend the applicant improve the stormwater runoff. Improvements would be to 52 replace existing hardcover in areas where plastic is used around landscaping and 53 replace it with permeable products. Sparks said the Watershed would also like to see 54 reduced hardcover on the lot which would assist in less runoff to the lake. 55 56 Sparks said by granting a Variance for this property it wouldn't be creating 57 precedence for others. He further suggested stormwater management be reevaluated. 58 59 R. Reid asked why the applicant needed a variance when they are reducing the 60 setback distance from original variance approved. Sparks explained that the original 61 Variance was approved for the deck and not for a full addition. Finke said the request 62 increases what was originally approved by increased massing of the addition going up 63 three stories and an additional deck. 64 65 Osmanski asked where the stormwater was located. Finke and Sparks explained its 66 location and that the catch basin would be to catch their own drainage. Nolan asked 67 what ideas would be helpful on a residential scale. Sparks said staff would have the 68 City Engineer look at it to determine what would be best. He said perhaps a small 69 raingarden to slow the water from getting to the lake. He said it would need to be 70 large enough to serve the purpose. Foote asked if any of theother land owners had 71 anything similar and Sparks said he couldn't tell from the applicant's location. 72 73 Nolan asked if the construction of the home not meeting the setback was by the 74 current owner. Sparks said no, it was a different land owner. 75 76 Public Hearing opened at 7:00 p.m. 77 78 Applicant Sandra Fenske of 2959 Lakeshore Avenue explained that the City had 79 made improvements to some of the runoff issues in the area and sees huge 80 improvements from Balsam. She said she'd be willing to take the plastic out from the 81 landscaping areas. Nolan asked the size of the house and she said it was a four 82 bedroom. Nolan asked what prompted the dimensions for the addition and Fenske 83 said it was determined by the current size of the deck. Dave Raskob, the applicant's 84 builder, explained that he's a neighbor and builder and wanted to work with the 85 existing conditions and make the same size with no additional impact to the lake. 86 Nolan asked what was currently on the ground elevation under the deck. Raskob said 87 it currently has a concrete slab which is cracked and would be taken out and replaced 88 to improve it. 89 2 1 1 90 Foote asked if the applicant gets water from the neighboring properties. Fenske said 91 they used to get water from the lot to the north but they made improvements with a 92 swale and don't have issues any longer. 93 94 Public Hearing closed at 7:37 p.m. 95 96 Osmanski, Foote, and R. Reid said they would approve the variance if the applicant 97 reduced the impervious surface. Nolan said he didn't see exchanging the plastic for 98 the fabric as an equal exchange. He asked for the applicant to look at some of the 99 hard surface areas and to reduce it further. He suggested trading a built surface for 100 landscaping or forgoing the grilling deck or the deck out by the lake. Nolan 101 commented that the applicant is adding to the footprint. Osmanski suggested a 102 specific percentage of reduction be recommended as an option. Nolan said at a 103 minimum he would want to see the drainage system improved. He said it's common 104 for properties to be able to mow right up to the lake, but then there isn't anything to 105 stop the chemicals from going into the lake. Foote said they were all good points and 106 if they lowered the size of the addition that would be acceptable. Nolan said they 107 wouldn't have to lessen the addition size, but rather eliminate the grilling deck, 108 sundeck, fire pit or something. 109 110 R. Reid asked if Nolan's issue was the additional 86 square feet being added for the 111 deck. Nolan said it was the increased hard cover on a lot that currently doesn't meet 112 the minimum and are asking for something additional. 113 114 Motion by Foote, seconded by R. Reid to recommend approval of the Variance 115 to the setback requirements from the OHWL on Lake Independence for an 116 addition and deck onto their home, conditioned that the private drainage is 117 improved as recommended by staff and the impervious surface be reduced 118 including but not limited to the areas within the landscaped areas. Ayes by 119 Foote, Osmanski, and R. Reid. Nay by Nolan. Motion carried. (Absent: V. Reid 120 and Kent Williams). 121 122 7. Public Hearing - Ordinance Amendment to Chapter 8 of the Medina City Code 123 relating to required street widths. 124 Finke presented the street width regulation changes. Nolan asked what the previous 125 changes were. Finke said the previous ordinance didn't have minimum standards in 126 City Code. He explained that in December a new ordinance was adopted relating to 127 road improvements which required a minimum roadway width. As recommended 128 currently, any subdivision with three lots or more would require a road meeting 129 minimum roadway width requirements. The proposed changes in the draft ordinance 130 modify the number of lots that trigger the road improvement. One lot into two lots 131 would not be required to meet the minimum width requirements. Foote asked as an 132 example, if a property owner came in and wanted to divide their one lot into two lots 133 and it was approved and didn't need to make improvements, but then a neighbor on 134 the same road comes in to divide their one lot into two, would the second party on the 135 roadway have to improve the road? Finke responded by saying the ordinance 3 136 presumes some sort of improvement, but the two owners on the same road could seek 137 the same flexibility without having to widen the road, but they would not be able to 138 then apply again and further subdivide any portion of the original lot. 139 140 Nolan asked staff if they were aware of any other municipalities that allow less than 141 20 feet in width roadways. Finke said not to his knowledge with new streets. He said 142 currently a person on an existing road wouldn't be allowed to subdivide without 143 improving the entire road to 20 feet in width. 144 145 Nolan asked if a cap should be put on the flexibility of people subdividing on a 146 narrower road. Finke said the ordinance is written to provide the City a lot of 147 flexibility. R. Reid asked at what point is a driveway turned into a road. Finke said 148 over two lots would trigger it. 149 150 Neil Wolf, Hamel Fire Department, said 20 feet is for a reason, because they are 151 driving big trucks. Running a 24 foot truck which is 8 %2 feet wide in 10 below zero 152 temperatures with trees along the road is difficult. He said some driveways are as 153 long as a quarter of a mile in length and he feels the width standards are there for a 154 reason and that it works. He said some of the houses being built are the size of a 155 commercial building (5-10,000 square feet) and their trucks can't get down an 18 foot 156 roadway. The standard fire access road requirements need to remain. 157 158 R. Reid asked how we separate the difference of a driveway and a road. Wolf said a 159 lot of existing private roads are as difficult to maneuver through as are driveways. 160 161 Nolan asked if there was any liability to the City if the roadway width was reduced. 162 Finke said the new ordinance would allow staff to have the ability to discuss requests 163 related to road widths. Wolf said he doesn't want to deviate from the 20 foot 164 requirements. Finke said the new urban subdivisions will be 28 feet and it's the rural 165 property areas that would have the flexibility. Finke said that Wolf made a good 166 point concerning rural areas possibly needing more road width than urban areas since 167 urban areas have fire hydrants. Wolf said it's a difficult task at best to make sure no 168 one gets hurt, but with the long winters it's dangerous with the ice and weight of the 169 trucks. Inherently the tanker trucks are the most dangerous to drive. If a fire is at a 170 home and it has a long driveway it should have appropriate accessibility with a 20 171 foot wide driveway for safety reasons. He said the Fire Department has 8-12 minutes 172 to mitigate a fire. 173 174 R. Reid asked how wide a tanker was and Wolfe said Hamel's is 8'8". Finke 175 explained that with snow plowing the guys run into the same problem, though the 176 City has the option to use different vehicles based on the location they are plowing. 177 Wolfe added that it's happened once already where the fire trucks couldn't access the 178 house due to site circumstances and accessibility. 179 180 Public Hearing opened at 8:20 p.m. 181 4 182 Bob Mitchell of 1745 willow Drive said in his building he had to have a water 183 bladder in each building until the City built a water tower. He said if properties aren't 184 accessible to the Fire Department, insurance companies aren't going to insure the 185 building(s). 186 187 Public Hearing closed at 8:22 p.m. 188 189 Foote said he's generally been in favor of wider roads. He said he would like to keep 190 it at 20 feet in width which would then not open up the City to legal issues. Osmanski 191 said he is in favor of safe streets, but to allow flexibility to create adjustments to 192 existing narrower streets for small subdivisions would be nice if it wouldn't put the 193 fire fighters at risk. 194 195 R. Reid asked if the City had reduced the roadway widths on any subdivisions. Finke 196 said only one he could think of was 20 feet in width. He said the question is if 197 someone comes in would the 18 foot road be sufficient with improvements or would a 198 24 or 28 foot roadway width be required. Foote said his concern is multiple 199 subdivisions serviced by an 18 foot wide roadway. Nolan asked if they were talking 200 about the road or the driveway. Finke said the road to get to the driveway. 201 202 Nolan asked Wolf if the ordinance would allow flexibility and if safety is a factor in 203 design. Wolf said he maintains the opinion that a 20'width road should be required 204 since trucks will only be getting larger. The ability to allow people to not meet the 20' 205 roadway width would only increase the number of requests the City would see. Wolf 206 said he still maintains the opinion of requiring 20' roadway width. Foote asked Wolf 207 how he felt if pullover areas would be created and Wolf responded by saying it would 208 still be a danger to his fire fighters when they pull over on a class five roadway. 209 210 Motion by Osmanski, seconded by Foote, to deny the Ordinance Amendment to 211 allow flexibility to reduce street widths less than 20 feet. Motion carries 212 unanimously (Absent: V. Reid and Kent Williams). 213 214 8. Continued Public Hearing — Thomas T. Morrison — Lot Subdivision of one 215 existing Lot into Two Lots at 1525 Hunter Drive (ND 25-118-23-22-0005) and a 216 Variance from minimum Road Width requirements. 217 Sparks presented the application. He explained to the Commission that the applicant 218 withdrew his request for a Variance to the road width requirements today, but would 219 still like to subdivide his property. 220 221 Foote asked how long the road was and Sparks said about a quarter mile. Nolan said 222 he wasn't at the meeting last month and went to the property and didn't think that it 223 would be that difficult to expand. R. Reid commented that there would be quite an 224 expense to widen and make the road improvements. She further asked what the 225 narrowest and widest points of the road were. Sparks explained it ranged between 18 226 feet and 20 feet. Finke said they've gone out since winter and the road is on average 227 18 '/2 feet wide. Nolan asked what design specifications the City would require for a 5 228 private road. The Commission discussed and Finke said it would have to meet City 229 regulations. 230 231 Truck Morrison, the applicant, said he withdrew his request for a Variance. He said 232 since the previous meeting he had met with the Ferris's lawyer and had worked 233 through concerns they had about the driveway running parallel along their property. 234 Morrison said they agreed to install eight spaded trees to place anywhere the Ferris's 235 so choose. Foote asked if the applicant was willing to build the road to the 20 foot 236 width standard and Morrison said if they had to they would, but are hoping to not 237 have to widen the area closest to Hunter Road. 238 239 Ferris of 1535 Hunter Drive said he thought six more homes could be allowed along 240 their roadway and is inevitable. So by definition, the area will become a development 241 over time. He thinks the road width issue will continue over time. 242 243 Morrison said three of the nine homes have driveways '/ mile long and narrow. Nolan 244 said if the driveway isn't safe for a fire truck to drive down, then property owners are 245 losing some of the fire protection. 246 247 Public Hearing closed at 8:52 p.m. 248 249 R. Reid asked for clarification concerning there not being a need for a Variance since 250 they were just subdividing one lot into two. Finke said yes and that a condition 251 should be placed on the application to require the road to meet City standards. 252 253 Finke suggested the applicant and Ferris have a formal agreement with staff 254 reviewing it as it relates to the easement for the driveway. The Commission agreed to 255 include it as a condition. 256 257 Nolan said he is pleased that two property owners could get together and resolve their 258 differences since he hadn't seen it happen very often. 259 260 Morrison asked if they could have more than 180 days to file with the County and the 261 Commission said they would be willing to allow. 262 263 Motion by R. Reid, seconded by Foote, to approve a Lot Subdivision of one 264 existing Lot into Two Lots conditioned on modifying condition number four to 265 require a 20 foot roadway being constructed and to allow for the applicant to 266 have more than 180 days to file the necessary paperwork with Hennepin County 267 to effectuate the lot split. Motion carries unanimously (Absent: V. Reid and 268 Kent Williams). 269 270 9. Continued Public Hearing — Ordinance Amendment to Chapter 8 of the Medina 271 City Code related to flag lots, lot frontage, driveway regulations, minimum street 272 grades, and the use of public easements and rights -of -way. 273 Finke presented the ordinance Amendment. 6 i 274 275 Nolan asked at what point does a driveway become a road. Finke said with four 276 homes. Finke said the minimum width standard deals with the reduction of side 277 loaded garages. It also requires new driveways in nonrural districts to be paved 278 which are common in suburban areas. The frontage of a flag lot should have a 279 minimum of 1% street gradient. Finke said rural lots would be required to have 60 280 feet of street frontage. Martin asked why 60 feet and Finke said it was chosen to be 281 consistent with the rural right-of-way width requirements. Finke explained that the 282 width would be wide enough to create a road if necessary in the future. 283 284 Martin asked for clarification of suitable soils within private roads or access 285 easements. Finke explained that suitable soils under private streets within outlots do 286 not count for adjacent property. He noted that the proposed ordinance amendment 287 would treat the area within an access easement the same as if it were in an outlot, and 288 it wouldn't be counted towards the suitable soils for either property. He noted tha the 289 reason for this is that locating a septic system within the access easement would be 290 inconsistent with its use for access. However, if the subdivider proposed a flag lot, 291 suitable soils within the flagpole would be counted towards the lot in which they are 292 located. 293 294 Finke explained utility easements are a big concern. Drainage is typically 295 accommodated in rear drainage utility easements and property owners tend to do what 296 they think are minor improvements that cause drainage issues. Nolan asked if we 297 would review these requests. 298 299 Continued Public hearing closed at 9:19 p.m. 300 301 Motion by Foote, seconded by R. Reid to Approve the Ordinance Amendment 302 related to flag lots, lot frontage, driveway regulations, minimum street grades, 303 and the use of the public easements and rights -of -ways as drafted and conditions 304 within right-of-way. Motion carries unanimously (Absent: V. Reid and Kent 305 Williams). 306 307 10. Council Meeting Schedule 308 Nolan to attend and present at the May 21st, 2013 Council meeting. 309 310 11. Adjourn 311 Motion by Osmanski, seconded by R. Reid, to adjourn at 9:22 p.m. Motion carried 312 unanimously. (Absent: V. Reid and Kent Williams) 7 AGENDA ITEM: 7 MEMORANDUM TO: Planning Commission FROM: Dusty Finke, City Planner DATE: June 6, 2013 MEETING: June 11, 2013 Planning Commission SUBJ: Complete Eye Care — Site Plan Review —170 Westfalen Trail (southwest of Hwy 55 and Sioux Drive) Review Deadline Complete Application Received: May 14, 2013 120 -day Review Deadline: September 11, 2013 Overview of Request Dr. Gina Wesley, owner of Complete Eye Care of Medina, proposes to construct a building with a floor area of approximately 4442 square feet within the Hamel Station commercial development at 170 Westfalen Trail (immediately west of West Financial). Complete Eye Care currently leases space and operates in Medina. The subject property is 18,310 square feet in size, located west Sioux Drive along Westfalen Trail. Elm Creek is located immediately north of the site, with Highway 55 further to the north. Section 825.55-.59 of the City's zoning ordinance requires approval of a Site Plan Review by the City before a building permit may be issued for a new commercial building. The purpose of such review is to ensure compliance with relevant City regulations and to determine what conditions are necessary in order to promote public health, safety or welfare, to achieve compliance with [city] ordinances, or to accomplish the purposes of the district in which the property is located. Approved Site Plan In 2007, the City Council adopted Resolution 2007-56, approving the Hamel Station commercial development. This resolution is attached for reference. The property was rough graded during the development of the Hamel Station project. Half of the access drive to the site is located on the property and the remaining is vacant. This resolution included approval for development of three lots: a 5,476 square foot credit union (West Financial) to the east; a 9,216 square foot retail building to the west, and a drive-thru coffee shop of 1,750 square feet on the subject property. The resolution also approved a series of variances. One variance allowed additional hardcover upon the development site than is permitted in the Shoreland Overlay District of Elm Creek. Another variance approved of retaining walls and parking (already constructed) within the 50 foot setback from Elm Creek. Additionally, variances were approved for the subject property allow a drive-thru closer to Sioux Drive than permitted in the Uptown Hamel zoning district. The drive-thru variances are no longer relevant since none is proposed (and the property has subsequently been rezoned and the setback for drive-thru is no longer required). Complete Eye Care Page 1 of 6 June 11, 2013 Site Plan Review Planning Commission Meeting The proposed building is larger than was approved during the 2007 review. As a result, an amended Site Plan Review was necessary. Staff has reviewed the conditions applied to the 2007 site plan review approval. Most of the conditions were satisfied during the initial development of the site. The two outstanding matters are for specific utility and grading plans to be approved with each building permit and the applicant will need to obtain approval from the Elm Creek Watershed Commission for this amended plan. Subsequent to the 2007 approval, the property was rezoned to the Commercial Highway - Railroad (CH -RR) zoning district and various other City regulations have changed. As a result, the City reviewed relevant to current standards. However, staff assumed that the 2007 variance would still apply, and that the site would be permitted the same amount of hardcover approved for the subject property during the 2007 review (13,230 square feet). Analysis The proposed use is an eye clinic. Professional and medical clinics are a permitted use within the CH -RR zoning district. As noted above, the applicant proposes a building with a floor area of 4,442 square feet. Resolution 2007-56 approved a 1,750 square foot coffee shop on the subject property. The coffee shop approved in 2007 included a large concrete patio and a drive-thru lane. The applicant proposes to increase the size of the building, but not increase hardcover. Staff does not oppose the increase in floor area, provided matters such as setbacks, hardcover, and parking are not negatively impacted. The applicant proposes to construct parking to the north of the proposed structure. This parking lot is part of a broader shared parking lot which was intended to serve the entire Hamel Station development. Setbacks / Hardcover The following table summarizes the lot requirements of the CH -RR district in comparison to the proposed site plan. CH -RR District Requirement Variance Allowed Proposed Front Yard Setback 25 feet 620 feet Frontage Road 0 feet 10 feet (Westfalen) Arterial Roadway 50 feet 111 feet (Hwy 55 ROW) Rear Yard Setback 25 feet N/A Side Yard Setback 15 feet 15 feet Parking Setbacks Front/Street 25 feet 70 feet (Westfalen) Rear/Side 10 feet, 0 if shared Shared with properties to the east, west, and north Residential 40 feet N/A Elm Creek Setback 50 feet Impervious Surfaces 25% (shoreland) 72.3% 76.3% Building Height 45 feet 27.5 feet Complete Eye Care Site Plan Review Page 2 of 6 June 11, 2013 Planning Commission Meeting The plans submitted by the applicant meet the dimensional standards of the CH -RR district with the exception of maximum impervious surface coverage. Although a variance was granted in 2007 for additional hardcover, the plans originally submitted by the applicant proposed an additional 744 square feet of hardcover. The applicant has reviewed the plans and determined that hardcover can be reduced by 764 square feet as described in their attached narrative. Staff recommends this reduction as a condition of approval. Wetlands/Floodplains As noted above, Elm Creek flows just to the north of the subject property. The wetland adjacent to Elm Creek requires a buffer of 30 feet, and the Elm Creek Watershed required a 50 foot vegetative buffer adjacent to Elm Creek during the review of the Hamel Station development. No wetland impacts are proposed, and the proposed improvements meet the City's upland buffer requirements and do not alter what was previously approved by Elm Creek. Staff recommends that signage be added along the buffer consistent with City regulations. A floodplain also exists adjacent to Elm Creek to an elevation of 967.14. No impacts are proposed. The seller of the property had agreed to conduct restoration along Elm Creek during the initial development of the site. Instead, the seller removed a large amount of significant trees along the creek in violation of City ordinances and the restoration plans for Elm Creek. The City and the seller came to an agreement related to mitigation for these impacts, which included replacement plantings and a contribution to the environmental fund. The seller has begun maintaining the replacement trees and vegetation consistent with plans and the City's ecologist believes it is on track to be established this fall. The City holds a financial guarantee to ensure. Building Materials and Design The table below summarizes the building requirements of the CH -RR district in comparison to the proposed building plans. The proposed plans appear to abide by the district standards. One of the requirements of the CH -RR district is that any building facade which faces a street or residential zoning district should be "4 -sided" architecture and be consistent with the quality expected on the front of a building. The south side of the building, facing Westfalen Trail, includes windows and is fairly well modulated. Staff does not believe that any of the elevations feel like the "back of a building" and that the structure does have a 4 -sided look. CH -RR District Requirement Proposed Exterior Building Materials Brick, stone, glass, stucco Min 30% 82% Decorative Concrete Max 70% 0% Metal, wood, fiber cement Max 20% 18% Modulation/Articulation South Elevation 1 per 40 feet 1 per 30 feet North Elevation 1 per 40 feet 1 per 15 feet East Elevation 1 per 40 feet 1 per 17 feet West Elevation 1 per 40 feet 1 per 24 feet Fenestration (window coverage) "Generous" Generous Complete Eye Care Site Plan Review Page 3 of 6 June 11, 2013 Planning Commission Meeting Stormwater and LID Review The applicant proposes to utilize the existing stormwater improvements which were constructed during the initial site development in 2007 to control the rate of stormwater runoff. The proposed site plan does not incorporate low impact design (LID) principles. The City updated its stormwater management regulations after the stormwater improvements were approved and constructed and the improvements would not meet the updated standards. The stormwater management ordinance does allow for the City to waive full compliance with the updated standards if a stormwater management plan has been approved prior to the standards coming into place. Because half of the site was graveled and there was no stormwater treatment before the Hamel Station development, the City Engineer estimates that the improvements approved in 2007 reduced nutrient loading by 20%. The pond also controls the rate of runoff consistent with today's standards. Access/Driveway/Parking The applicant proposes to utilize the existing shared driveway which was constructed in the initial development of the West Financial building. When the property to the west develops, the access drive will continue through and connect with Westfalen Trail to the west. The original plan was for the Hamel Station project to be owned by a single entity, which is no longer the case. As such, staff recommends that reciprocal easements and maintenance agreement be recorded against all three properties to allow for access and shared parking. The applicant proposes to construct 20 parking spaces, 9 of which are at least partially located on adjoining property. Shared parking was planned for the Hamel Station commercial project. Although the floor area of the building is proposed to be increased, the change of use from coffee shop to medical office actually reduces the required parking from 18 spaces to 17 spaces. Ten parking spaces were approved on the subject property during the 2007 review, and 11 spaces are now proposed. Staff does not believe that the parking is negatively impacted as a result of the change of use and amended site plan. Landscaping/Tree Preservation There are no significant trees located on the property, so no tree removal is proposed. A landscaping plan was approved during the development of the Hamel Station site. The approved site plan from 2007 planned for 3 overstory trees, 7 ornamental trees and 70 shrubs. The applicant proposes to plant 3 overstory deciduous trees, 7 ornamental trees, and 32 shrubs. As noted previously, the property has also been subsequently rezoned since the 2007 approval. The requirements of the CH -RR district would require 10 overstory/coniferous, 5 ornamental trees and 17 shrubs. The Planning Commission and Council may wish to discuss whether additional landscaping should be required as a result of the increased building size or the new requirements of the CH -RR zoning district. Two landscaping islands totaling 180 square feet were shown on the approved site plan in 2007. The applicant proposes to construct a single landscaping island on 90 square feet. In addition, Complete Eye Care Page 4 of 6 June 11, 2013 Site Plan Review Planning Commission Meeting the applicant proposes 180 square feet of landscaping adjacent to the handicap parking stall. The CH -RR zoning district would require significantly more landscaping within the parking lot (8% of the area, or 580 square feet). Staff would recommend against a reduction in landscaping within the central portion of the parking lot area, and recommends that this be amended. It may be preferable for the survival of plants to increase the width of the single island rather than adding another small island. The applicant proposes to sod the area adjacent to the building. The area north of the parking lot will be native vegetation for the Elm Creek buffer. Lighting The applicant proposes lighting on the existing building. This lighting will be required to be downcast and shielded, consistent with City standards. Staff recommends a condition that photometrics be submitted to verify consistency with the 0.5 footcandle maximum at property lines. Trash and Recycling Facilities/Mechanical Equipment The applicant proposes to store trash and recycling containers within the building. No areas have been identified for storage on the plans, so staff recommends a condition to update plans to show how this will be handled. The CH -RR ordinance requires that mechanical equipment be screened with walls which are constructed of materials which are compatible with the building or opaque landscaping. Staff recommends a condition consistent with this requirement. Utilities The City Engineer and Public Works have reviewed the proposed utility plan and made technical recommendations. Staff recommends compliance with these recommendations as a condition of approval. Loading Dock/Outside Storage of Service Vehicles No loading docks are proposed. The proposed use has limited loading needs. Staff recommends a condition that loading and deliveries occur from the parking lot is such a way that does not interfere with circulation. The CH -RR ordinance limits outside storage of service vehicles (under 24 feet in length) to one vehicle per 10,000 square feet of building footprint. While the proposed use does not include the need for such parking, staff recommends a condition informing the applicant that a maximum of one service vehicle may be stored within the parking lot. Review Criteria/Staff Recommendation The purpose of a Site Plan Review, as described in Section 825.55, is to review proposed construction for consistency with City regulations. The City "may condition its approval in any manner it deems reasonably necessary in order to promote public health, safety or welfare, to achieve compliance with this ordinance, or to accomplish the purposes of the district in which the property is located." Complete Eye Care Page 5 of 6 June 11, 2013 Site Plan Review Planning Commission Meeting Staff believes that the proposed amendment to the approved site plan is consistent with City regulations and policies, subject to the terms and conditions noted below. Staff, therefore, recommends approval with the following conditions: 1) Except as modified herein, construction shall be consistent with the plans received by the City on May 13, 2013. 2) The applicant shall enter into a development agreement related to the terms and conditions contained herein and other relevant City requirements and policies. 3) The applicant shall update plans to reduce impervious surface coverage to 13,230 square feet or less. 4) The applicant shall update plans to provide a minimum of 180 square feet of landscaping within the center of the parking lot area. 5) The applicant shall provide specifications on proposed lighting, which shall be downcast consistent with City requirements. The applicant shall also submit photometric plans of lighting which ensure no more than 0.5 footcandles of light trespass at rights -of -way. 6) The applicant shall update plans to identify storage areas for trash and recycling. Such storage shall be within the building, unless an alternative is provided which meets City requirements. 7) Mechanical and HVAC equipment shall be screened with building materials consistent with the building or adequate vegetation. 8) Except as modified herein, the applicant shall abide by the recommendations of the City Engineer dated 5/29/2013 and City Planner dated 6/4/2013. 9) The applicant shall record easements and maintenance agreements, in a form and of substance approved by the City, which provide for shared access and parking. 10) The applicant shall install upland buffer signage consistent with the City's wetland protection ordinance. 11) Loading and deliveries shall occur from the off-street parking area and shall not interfere with circulation. 12) A maximum of one vehicle utilized for the use permitted on the property may be stored within the off-street parking area. Such vehicle shall be currently licensed, operable, less than 24 feet in length, and not more than 12,000 lbs. of gross vehicle weight. No outdoor storage shall be permitted. 13) The applicant shall obtain necessary permits from the City, Elm Creek Watershed, Minnesota Department of Health, and any other relevant agency prior to commencing construction activity on the property. 14) Construction hours shall be limited to 7:00 a.m. to 8:00 p.m. Monday through Friday and 8:00 a.m. to 5:00 p.m. Saturday and Sunday. 15) The applicant shall pay to the City a fee in an amount sufficient to reimburse the City for the cost of reviewing the site plan and other relevant documents. Attachments 1. Applicant Narrative 2. Resolution 2007-56 3. City Engineer comments dated 5/29/2013 4. City Planner comments dated 6/4/2013 5. Plans received by the City 5/13/2013 Complete Eye Care Page 6 of 6 June 11, 2013 Site Plan Review Planning Commission Meeting BJ BAAS Builders, Inc. June 6, 2013 Mr. Dusty Finke, City Planner City of Medina 2052 County Rd 24 Medina, MN 55340 RE: Complete Eye Care/Wesley Holdings, LLC construction at 170 Westfalen Trail, Medina, MN Dear Mr. Finke: This letter is in response to your recent letter dated June 4, 2013, and follow up phone conversations regarding the impervious surface area on the referenced lot. This letter serves as notification that we have redesigned the site plan to reduce overall impervious surface by a total of 764 square feet. We accomplished this by making the following adjustments: • Narrowing of sidewalks o 4/except at front of building) • Move sidewalk from East side of building to West, and split property line • Narrow Drive lanes to 22' wide • Eliminate concrete in island adjacent to handicap parking stall As per our conversation, we will re -submit a new site plan drawings that represents the noted changes prior to the upcoming City Council meeting in July. Should you have any questions regarding these changes, feel free to contact me. Respectfully, B ian J. Baas C.C. Dr. Gina Wesley Lea Kangas, Inside Outside Architecture Brent Roshell, PE, Anderson -Passe Engineering 330 N. Emerson Street Cambridge, MN 55008 www.bjbaas.com P: 763.691.0444 F: 763.691.0555 Member Johnson introduced the following resolution and moved its adoption: CITY OF MEDINA RESOLUTION NO. 2007-56 RESOLUTION GRANTING AMENDED SITE PLAN AND VARIANCE APPROVAL FOR THE UPTOWN HAMEL RETAIL DEVELOPMENT LOCATED AT 3575 SIOUX DRIVE REPRESENTED BY UNITED PROPERTIES WHEREAS, United Properties (the "Applicant") has requested approval for an amended site plan and with variances from the City Council ("the City") to operate a multi -use retail development with drive-in uses located at 3575 Sioux Drive (the "Subject Property"), which is legally described on Exhibit A attached hereto; and WHEREAS, the City Council originally approved the site plan with variances for the Subject Property on May 1, 2007; and found that exceptional and extraordinary circumstances do apply to this property due to the topography and proximity to Elm Creek; and FURTHER, that the Applicant has meet the intentions of the Uptown Hamel zoning district; and FURTHER, that the variances would not be materially detrimental to the purposes of the ordinance under which the property is zoned, and the Applicant has provided the minimum necessary improvements to alleviate the hardship, and that the Applicant is furthermore reducing the impervious surfaces and improving the site with the approved Site Plan; and FURTHER, that the applicant has demonstrated undue hardship because of circumstances which make the subject property unique as compared to other properties within the district; and WHEREAS, the City Council on September 18, 2007 reviewed the amended site plan with variances for its conformance with the City's ordinances and the terms and conditions of the original site plan approval, considered the recommendations of staff and heard comments from the Applicant; and WHEREAS, the City Council finds that the changes to the previously approved site plan with variances qualify as minor changes and that the amended site plan conforms with the conditions of preliminary approvals and the standards for the district in which the property is located; and Resolution No. 2007-56 October 16, 2007 WHEREAS, this resolution replaces the previously approved site plan and variance resolution (Res No. 2007-22) for the Subject Property; and NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF MEDINA, MINNESOTA that it should and herby does approve the request by United Properties for an amended site plan with the following variances for the Subject Property: 1. A variance to exceed the 25% maximum impervious surface shoreland requirement. The proposed development will increase the total impervious surface to 50% of the site. 2. A variance to allow the retaining wall to encroach 10 feet within the 50 -foot setback on the vegetative buffer on Elm Creek. 3. A variance to allow the driveway to the drive-in service businesses (the coffee shop and the credit union building) to encroach 80 feet within the 100 -foot setback from an improved intersecting street. 4. A variance to allow the driveway to the drive-in service business associated with the coffee shop to encroach 120 feet within the 300 -foot setback from State Highway 55. 5. A variance to allow the driveway to the drive-in service business associated with the credit union to encroach 20 feet within the 300 -foot setback from State Highway 55. NOW, THEREFORE, BE IT RESOLVED that the amended site plan and variance approval are subject to the terms and conditions are subject to the following terms and conditions: 1. The amended site plan with variances is approved, in accordance with the architectural plans received August 6, 2007 and the civil plans received August 29, 2007, except as amended by this resolution. 2. The amended site plan and variance approval shall be contingent on approval of a final plat for the Subject Property and all the conditions of final plat approval. Resolution No. 2007-56 2 October 16, 2007 3. The Applicant shall meet all of the Elm Creek Watershed Management Commission (ECWMC) conditions of approval addressed in the letters from ECWMC dated August 29, 2007 and September 5, 2007 that are still outstanding for the stream bank restoration and landscape buffer plan, the erosion and sediment control plan and the stormwater management plan prior to any work being conducted on the site. 4. The Applicant shall submit a complete set of updated civil plans prior to any work being conducted on the site that accurately shows that the proposed property boundaries are consistent with the final plat received August 29, 2007. 5. All conditions stated in the City Engineer's report dated September 11, 2007 shall be addressed by the Applicant. 6. The application for building permits must include grading, drainage and erosion control plans with each building plan submitted. 7. All signs shall be in compliance with the City's sign ordinance and if signage is lit, it shall meet the outdoor lighting standards as defined in the ordinance. 8. The Applicant shall dedicate a sign easement for a future freestanding community identification sign along the west side of Sioux Drive at a location to be determined by City staff. The freestanding project sign for the Hamel Station development shall be not be located within 50 -feet of the sign easement. 9. If the coffee shop is to have a menu board, the Applicant must submit the proposed sign prototype for review by the City prior to issuance of a building permit. 10. The proposed parking area shall meet all City design standards and ADA accessibility requirements. The plans should be revised prior to issuance of building permits to provide an acceptable handicap parking space and stripped access aisle for the coffee shop building. If an individual must cross the vehicle lane than a white painted crosswalk should be added. 11. The drive-in services must not be used between the hours of 10:00 p.m. and 6 a.m. 12. The Applicant acknowledges the potential adverse impacts of the Highway 55 corridor planning efforts as presented in the City Council Special Meeting held on April 17, 2007, which may result in encroachments beyond the dedications made by the Applicant on the plat. Resolution No. 2007-56 3 October 16, 2007 13. The Applicant must enter into a development agreement and a petition and waiver agreement in forms satisfactory to the City to ensure completion of subdivision improvements and development of the project in compliance with all City requirements. 14. The Applicant shall pay to the City a fee in the amount sufficient to reimburse the City for the cost of reviewing the site plan and related documents. Dated: October 16, 2007 T.M. Crosby, Jr., Mayor Attest: Chad M. Adams, City Administrator - Clerk The motion for the adoption of the foregoing resolution was duly seconded by member Weir and upon vote being taken thereon, the following voted in favor thereof: Crosby, Smith, Weir, Johnson and the following voted against same: (Absent: Cavanaugh) None Whereupon said resolution was declared duly passed and adopted. Resolution No. 2007-56 4 October 16, 2007 EXHIBIT A Lot 33, Auditor's Subdivision No. 241, Hennepin County, Minnesota, except that part described as follows: commencing at the Southwest corner of said lot; thence on an assumed bearing of North 1 degree 29 minutes 40 seconds East, along the West line of said lot, a distance of 192.20 feet to the Northwest corner of said lot; thence North 61 degrees 35 minutes 39 seconds East, along the Northwesterly line of said lot, a distance of 55.78 feet; thence South 59 degrees 12 minutes 01 seconds East a distance of 101.50 feet; thence South 75 degrees 49 minutes 17 seconds East a distance of 91.63 feet to the point of beginning of the land to be described; thence continuing South 75 degrees 49 minutes 17 seconds East a distance of 125.00 feet: thence North 14 degrees 10 minutes 43 seconds East a distance of 60 feet; thence North 00 degrees 38 minutes 05 seconds East a distance of 10.05 feet to the South line of State Trunk Highway No. 55; thence North 79 degrees 29 minutes 35 seconds West, along said South line, a distance of 152.54 feet; thence South 75 degrees 49 minutes 17 seconds East a distance of 29.58 feet to its intersection with a line bearing North 14 degrees 10 minutes 43 seconds East from the point of beginning; thence South 14 degrees 10 minutes 43 seconds West, a distance of 60 feet to the point of beginning. Resolution No. 2007-56 5 October 16, 2007 WSB rs May 29, 2013 engineering • planning • environmental • construction Mr. Dusty Finke Planner City of Medina 2052 County Road 24 Medina, MN 55340-9790 Re: City Project: Complete Eye Care Site Plan Review, LR-13-108 WSB Project No. 2065-500 Dear Dusty: 701 Xenia Avenue South Suite 300 Minneapolis, MN 55416 Tel: 763-541-4800 Fax: 763-541-1700 We have reviewed the site plan dated May 8, 2013, for the proposed Complete Eye Care site. The plans propose to construct an eye care facility along with parking areas, storm sewer, utility connections, and landscaping. We have the following comments with regards to engineering matters. Sheet Cl Grading and Drainage Plan 1. The plans show the property boundaries and proposed construction going beyond the property lines. The applicant should provide evidence they have permission to construct improvements on neighboring properties. 2. The plans should include proposed 1 -foot contours. 3. Storm sewer calculations should be provided. 4. The proposed sanitary sewer and water connections are shown being cut into the existing systems. The applicant should utilize existing sanitary sewer and water stubs to this site if they exist. The as -built utility information for this site should be included in this plan set. 5. More sanitary sewer service detail should be provided including proposed invert elevations and cleanout locations. 6. The plans should include more detail in the northeast corner of the site where the existing bituminous berm is to be removed. The berm was installed to prevent an erosion problem at the north end of the drive aisle at the MCES access to their facilities. The plans should show how the proposed storm sewer on the subject site will accommodate the drainage previously diverted to the storm sewer on the neighboring property to the east. 7. The proposed storm sewer system shall collect all drainage from the proposed site improvements. It appears storm sewer needs to be added to collect drainage from the westerly part of the site. St. Cloud • Minneapolis • St. Paul Equal Opportunity Employer wsbeng.com K.. 0?065-500,AdminDacs1Complere Eve Core Sire Plan Revie,w052913.doc Complete Eye Care Site Plan Review May 29, 2013 Page 2 8. It is unclear why CB 4 is necessary. The applicant should provide clarification why this structure is necessary. 9. The City does not allow irrigation from the municipal water system. Future submittals should identify how water will be supplied for irrigation. Sheet C2 Civil Details 1. City standard details should be included in the plan set and replace the details shown. 2. The proposed parking lot section should match the section used on the property to the east. Please contact me at 612-209-5113 if you have any questions. Sincerely, WSB & Associates, Inc. Tom Kellogg srb K:101065-5001AdminlDocs!Compkre Eve Care Site Plan Revie-O5?913.doc i MEDINA CITY OFFICE 2052 County Road 24, Medina, MN 55340-9790 ADMINISTRATION I PLANNING Sc ZONING I PUBLIC WORKS p: 763.473-4643 f: 763.473-9359 e: city@ci.medina.mn.us PUBLIC SAFETY p: 763.473.9209 f: 763.473-8858 June 4, 2013 Dr. Gina Wesley 6855 Old Settlers Road Corcoran, MN 55340 Dear Dr. Wesley: City of Medina staff has conducted a preliminary review of the materials submitted requesting Site Plan Review approval for your new building at 170 Westfalen Trail. The plan is largely consistent with the approved site plan for this site and City policies and regulations. Staff did note some items which will need to be adjusted, which are described below. Proposed hardcover exceeds that which was approved as part of the original Site Plan Review and Variance in 2007 by 744 square feet. Staff will be recommending that hardcover be reduced to be consistent with the 2007 approval. It appears that the removal of the sidewalk along the east and south of the building (or the utilization of porous surfacing) would reduce hardcover by 450-500 square feet. The southern drive aisle could also be narrowed which would reduce hardcover by approximately 75 square feet. Additional detail Is required related to plans for trash/recycling storage. Staff recommends that the applicant specify how the hardcover will be reduced (as a narrative, at the least) and where trash and recycling will be stored before the project proceeds to the Planning Commission. Additional detail is also necessary for the grading/drainage/stormwater management plan. The utility plan is required to be updated to show how a hydrant will be accommodated at the southwest corner of this lot as shown on the approved site plan and how the future hydrant to the north of the building to the west will be served. Staff recommends extending the existing 6" waterline in the parking lot to the western property line. As an option, the hydrant could be placed on the western property line for the possibility that it serve both buildings when the site to the west is ultimately developed. This information does not need to be updated before the Planning Commission meeting, but should be provided before approval by the City Council. www.ci.madina.mn.us The proposed landscaping plan appears mostly consistent with the approved landscaping plan for the development. Staff will note during the review process that the building size has been increased and that the approved landscaping plan does not meet the standards of the CH -RR zoning district. The Planning Commission or City Council may require additional plantings as a result. Additional comments from the City Engineer are attached. These are more technical comments which will need to be addressed before permits can be issued. This letter also serves as notice that the City will extend the review timeframe for this site plan review by an additional 60 days as described in chapter 15.99 of Minnesota State Statutes. The review deadline is September 11, 2013, although staff anticipates action will be taken far in advance of this date. If you have any questions, please do not hesitate to contact me at dusty.finke@ci.metdina.mn.us or 763-473-8846. Sincerely, — Dusty Finke City Planner CC: Brian Baas, BJ Baas Construction (via email: brian@bibaas.com) Dr. Gina Wesley (via email: gmweslev@yahoo.com) Project File CO DE ANALYSIS CHECIQIST IBC 2006 Propel Here :Ca n** Elm Cage _.. .. Prepared by: :LEK A. BASIC DATAltem Code Refere rar - Item • Semen 303 1 Occu pancy groulys ): M eer th e: B Tads 506.13 se men 908 2 Occu pancy sepa ra tio n re quired n Data 4/1912013 Chap. Tabs 602 Table 503 Bo ston 50. 1-511 Table 503 a. Wall 0 b. Open ing 0 3 Co r,tniction Type VB 4 Fee Re sistance Requ ire ments of Exte rior Walls : a. North: 0 b. Ea st: c. So uth: d. West Opening. OpeNngs Openin gs Openings Stan. Sto ries: 0: 0 0 0 0 5 Bu ilding Heights a. Allowable Height: b. Increase he Sprin klers: 0. A ctua l H eight: 6 Budding A rea s: A. O cctp erruy Type: t Bash Allowable 40 20' 208' 0 2 2 9000 5062 _... ... 2 In crease Fronta ge [179-16,247-10,.. 2512630 <3.xlllu-2941 606.3 3 In crease fo r Sprinklers, NFPA 13: rt03. 24 9801 4 Total Allo wable Area: 29943 C. Actua l Area: Total Area list floor: fo otprint __.. . ..Total are a seco nd floor: fo otprint B. FIR E RESISTIVE REQUIREM ENTS: Reference Item Tea 63' t Structu ral Frame: 2 Exterior Beenrp Walls: 3 Integer Be ating Walls: 4 Exterio r Non-Beenng Walls: 5 !Me na Non'Bmmtg Wa l!s:. .. 6 Fa rs - FloortCedings: 7 Ra ab • RonECN lags: 9 Exterio r Doors: 10 Exterio r Windows 12 Ro ot Cowlings: a ng er6 Orprw 6 prreue Al Stars : ton 15 Con dors: candor occ. Lo ad < 30 m all of 40 occ - 20) 0 Hours 115 16 Oohs (tjI@ iasy 0 Hours C. OUT REQUIREMEN TS: EN TS: Co de Re feren ce : -Ite m _. ... . 1004 and 100.1 1 I O ccupant Lo ad b. First Faor . N o, Exits: : 34 0. Upper Floor No Exits: 6 O. To tal: (for o ccupan cy gro up) 2 E xd Doors: 1095 a. M Room Width Regw red 36' Height 6'$ b Maximum Leaf Width Allowed- - a6 0, S win g Re wired'' 5ecem 1019 rt. Number of arils 1 (gl 2nd lax : 1g 1st loon, 2 ex its pr ovide d 3 Exit Co rridors: . ... 1017.2 a. M'wmum Required Yrgdln. _-- 44' 10173 b. Dead End Lando n Mowed? Maximum Length. -.56 0' 10171 c. Walt Fire Resistance Required: 0 7154 d D oors and Fr ame s Fire R esista nce Re quired: 0 ire 4 M aximum Caden ce Alkwsd to Exit: 300' ton. 21 5 End Separali Required M inimum: 281• Presided: 66-7 . _.. .: 1015 6 N umbe r of Stairwa ys Required 1020 - 7 . Era En closure Requirements: Not enclosed 1020.1 except 1.1 1410 oce. ) 10073 8 Sta r Dimen sion s Requited: ...... . _ a. Width M in imu m: 46 acce ssible ?minded. 60' b. Riser Maximu m: 7" Plaided: 613/16 Cpen: no Closed: Ye s c. . Trend M inimum. 11' Prided: 11' d Head Oemance Min imum: 86 Pleaded: 6d' o Distance Betwee n Landdnga M aximum: 12' Pro vided' 10.3' terse C __. _i __ . .... d_. _ LarxSng Gmensinn Minimum: - Pea 5' roots - g. Are a of Re fuge Minimum Size 30' X 48' 10091 h Handrail Requ iremen ts:. . __.. . T Requ ired et Each S de Yes 2 Inte rme diate Ra ils Re quired at Stairs no 3 M aximum Width Be tween Interior Reis:tip 4 Ex ceplans Applicable _. . no 5 Height Able N osing: 6 Minimum Spacin g Allow ed: 7 Handrails Return to Wa ll at Eats" B Exlamions a1 Ends Re qu ired: Bo th Sides .. . .. _. Top 17 , Bo tto m 23' ... averaver1111 Acces sibility 2ndKweno t re qu ired to be a cces sible 1101 a. Ro ute of Tavel: 1st lax route of trawl is a cdessiMe b. :Stain R equire d: not rea med 11098 0. O emlas Re quired:.. . .. .. .. . _. . tW7. 6 -. d Area or ReMgr. D. FIR E ALARM A ND SU PPRESSIO N SYSTEMS : Code Re fe ren ce Ite m 1 Fre Ex tinguisher System s: 5031 a. Sprinkle rs Re quire d: re quired pe r MSBC 13. 06 as adapted by Gaya/ M aine LETA lot a. Ere Extinguishers Require d: 3 travide d T•7 - 2 Drat Stops Re quired al: .._ nine'1 3000 SF M ECHAMCAU ELECTRICAL REOLIIREM ENTS: Code Ite m Re ferenc e 1 Talet R oan Require ments: a. Velure Co unt Req uirements Owger Nei 1 Men Re quirement Actual (a ) Lasa taies . .. _s ets...... Veeyeeh (b)Wa [a easels 6011 code (c) U tina ls en dda ebra&ml (d) Han dica pped Purr.. Cade 3500 942 0- Haute O Hours O Hou rs ... O Hou rs 0- . Hours.... O Hours O Ho ts 0 Hours O Hours O Hz O Hou r, 34' -38' 4' clear Ye s 2 Warren (a ) Lavatorie s (b) Water Closets (c) Handicappe d F. . Drinkin g Fountain ftequitemen ls: . Showers Re qu ire d: d. serwae Sinks: e. Floo rs: _.. . _ I. Walls:. D MISC. REQ UIR EMENTS: Code Item Refinnse 1 Rooing R egW re ments: t504 15W7 alas : - c Ma teria l asphalt shingles 8 standing seam metal Dratstops Re quired: no ne c 3000 SF attic spaces Ven t8a6o n Requ irements: Drainage '. 0 pe r MSBC 2007 2902.1 enc . F ceramic rite ce ramic tale W va t walla asphalt slope 6'12: standing seam slo pe 3/12 001 -WE 4 Finis hes: 7,3, 60 34 a Fame -Spread Classiiea ton R equired: Rooms Or Are as:.. . _. _.. .. . c. LOCATION MAP ABBREVATIONS N .I.C. U .N.O. FEC SIM M AX MIN E LEV TYP W/ W/O A DA COMPLETE EYE CARE N OT IN CON TRA CT UN LESS NOTED OTHERWISE FIRE EXTINGUISHER CABINET SIM ILAR MA XIMUM MINIMUM ELEV ATION TYPICAL WITH WITH OUT AMERICANS WITH DISABILITY ACT (ACCESSIBIL TY) PROFESSIONAL BUILDING 170 WESTFALEN TR MEDINA, MN 55340 CONTACTS ARCHITECT INSIDE OUTSIDE ARCHITECTURE, INC. (IO A INC.) CO NTACT: LEA KANGAS Phone: 763-428-5870 GENERA L CONTRA CTOR BJ BAAS BUILDERS, INC 330 N. Emerso n St. Cambridge, MN 55008 C ONTA CT: BRIAN BAAS Phone: 763-691-0444 OWNER COM PLETE EYE CARE DR. G INA WESLEY FIXTURE / ACCESSORY MOUNTING LOCATIONS LAV ATORY M IRROR PAPER TO WEL DISPENSER SAN ITARY NAPK IN VENDIN G HA ND DRYER TOILET PA PER HOLDER SANITAR Y NAPKIN DISPOSAL GRAB BARS URINAL WATER CLOSET TOILET PARTITION URINA L SCREEN FIRE EXTINGUISHER CABINETS ROOM SIGNA GE 2'-10' TO TOP OF BASIN (ADA MAX. ) 2-5' CLEAR BE LOW SINK (M IN.) TYPICAL MIRROR BOTTOM SET ABOVE BA CKSPLASH OR 6' ABO VE WALL M OUNT SINK BOWL. 3'4' MAX. TO BOTTOM R EFLECTIVE SURFACE OF M IRROR (ADA) 4'-U' MA X TO OPERA BLE PA RTS 4'-0' MAX TO OPERABLE PARTS 4'-0' MAX TO OPERABLE PARTS MIN. 12' AN D MAX . 40' FRO M WALL BEHIND WATER CLO SET. 18' MIN . ABOV E FLOOR. 1 1/2' MIN. BELO W HOR IZONTAL GRAB BAR MIN. 17 AND MA X. 40' FROM WAL L BEHIND WATER CLO SET. 16 MIN . ABOV E FLOOR. 1 1/7 MIN, BELOW HOR IZONTAL GRAB BAR TOP OF HORIZONTAL BARS 33'-36' ABOVE FLOO R. HORIZONTAL BAR BEHIND WATE R CLOSET TO BE 36 MIN . IN LENGTH AND TO EXTEND t2' M IN FROM C ENTERLINE OF WATER CLOSET TOWAR DS CLOSEST PER PENDICULAR WA LL AN D 24' M IN ALONG TRANSFER SIDE HO RIZONTAL BA R ALONG SIDE OF WATER CLOSET TO BE 42' MIN. IN LENG TH AND TO BEGIN M AX 12' FROM BACK WALL. SIDE VERTICAL BA R TO BE 18' MINIMU M IN LEN GTH TO BE MOUNTED WITH THE BOTTOM OF TH E BAR LOC ATED BETWEEN 39-41 IN CH ES ABOVE THE FLOOR WITH THE CENTER LIN E OF TH E BA R LO CATED BETWEEN 3941 INCHES FRO M REAR WALL 1'-10' TO BOTTOM OF OPENING (NON ADA) 1'-5' TO BOTTOM OF OPENING (A DA HT. ) 1'-3' TO TOP OF SEAT (NON A DA) 1'-6 TO 1' -T TO T OP OF SEAT (ADA HT.) CENTERLINE OF ADA WATER CLOSET TO BE 1'51' FROM WALL OR PARTITION WALL - 17 TO BOTTOM OF PARTITIO N 12" TO BOTTOM OF SCREEN. 54' TO T OP OF SCREEN 54' MAX. TO TOP OF CABINET COM PLY WITH ACCESSIBILITY REQ UIREMENTS - SEE ALSO 101 N OTES: 1. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING HEIG HTS OF FI XTU RES FURNISHE D BY THOSE SECTIONS 2. SEE INTERIOR ELEVATIONS FOR ADDITIONAL ACCESS ORY MOUNTI NG LOCATIO NS SHEET INDEX T1 TITLE SHEET, SHEET INDEX, A ND CODE SUM MARY Cl GRADING AND DRAINAGE PLAN C2 CIVIL DETA ILS C3 LANDSCAPE PLAN AS ARCHITECTURAL SITE PLAN Al FLOOR PLAN A2 REFLECTED CEILING PLAN AND ROOF PLAN A3 EXTERIOR ELEVATIONS & CO NSTRUCTIO N TYPES A4 BUILDING SECTIONS AND WALL SECTIONS A5 BUILDING SECTIONS, WALL SECTION S AND DETAILS A6 INTERIOR ELEVATIONS A7 INTERIOR ELEVATIONS, RECEPTION DESK PLAN AND DETAILS A8 DOOR SCHEDULE, DOOR AND WINDOW TYPES A9 FINISH PLAN A10 REFERENCE FURNITURE PLAN, FINISH SCHEDULE AND SPECIFICATIO NS S000 GENERAL STRUCTURAL NOTES 5001 FASTENING SCHEDULE S100 FOUNDATION PLAN S101 SECOND FLOOR FRAM ING PLAN S102 RO OF FRAMING PLAN S400 SHEAR WALL PLANS S401 DETAILS S500 DETA ILS S501 DETAILS GENERAL NOTES MAY 1 ALL CONTRA CTORS MUST REVIEW ALL D OCUM ENTS TO QUANTIFY SCO PE OF WORK PRIOR TO SUB MITTING BIDS 2. CO NTRACTORS TO VERIFY ALL CONDITIONS AND DIM ENSIONS PRIOR TO STAR T OF WORK NOTIFY ARCHITECT OF DISCREPANCIES 3. MECHA NICA L. ELECTR ICAL. AND PLUMBING DESIG N BY OTHERS. A NY WORK SHOWN ON AR CHITEC TURAL DRAWINGS THAT IS WE/P IS FOR REFERENCE ONLY. SEE ALL KEYNOTES FOR ADDITIONAL MIE/P I NF ORMATION 4. ELEC TRICAL TO COORDIN ATE WITH O WNER AND ARCHITECT FOR OWNE R'S E QUIPMENT, POWE R, AND DATA NEEDS 5. LIGHTING SHOWN ON ARCHITECTURAL REFLECTED CEILING PLAN IS FOR REFERENCE ONLY. SEE MECHANICAL AND ELECTR ICAL PLA NS 6. ELECTRICA L TO ENSURE PROPER LIFE SAFETY LIGHTING. EMER GENCY LIGHTIN G, AND EXIT SIGNAGE IS PROVIDED THROUGHOUT SEE FINISH SPECIFICATIONS AN D ROOM FINISH SCHEDULE ON DRAWIN GS . C OO RDIN ATE WIT H AR CHITECT 8. DIM ENSIONS TO WA LLS ARE TO THE FACE OF FINISH OF THE WALL AT INTERIOR AND TO EXTERI OR FACE OF SHEATHING AT EXT ERIO R, U.N.O . 9. CEILING HEIGHTS TO BE AS INDICATED ON THE REFLECTE D CEILI NG PL AN AND FINISH S CHEDULE. NOTIFY ARCHITECT OF ANY DISC REPAN CIES 10, REFERENCE FURNITURE PLAN IS FOR REFERENCE ONLY . FURNITURE PROVIDED BY OWNER , C OORDINATE WIT H ARCHITECT 11. A RCHITECT NOT RESPONSIBLE FOR DETECTI ON AND/ OR ABATE MENT OF HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO LEAD. MOLD AND RADON 12. DO NOT SCALE DRAWINGS F OR CONSTR UCTI ON PURPOSES 13. REFER TO STRUCTURAL DRAWINGS FOR W OOD FRA MING REQUIREMENTS 14. CABINETS, COUNTERTOPS. ETC. S HOWN TO BE 'RELOCATED ' WILL BE RE MOVED FROM THE OWNER 'S CURRENT FACILITY RELOC ATED TO THE NEW FACILITY AND RE -INSTALLED BY THE OWNER 'S VENDOR. ORIGINAL R OOM NO 'S REFERENCED ARE FOR COORDINATION PURPOSES ONLY. CO NTRACTO R(S) SHALL COORDIN ATE WITH VENDOR F OR LOCATIO N OF BLOCKING . PLUMBIN G ROUGH -INS . ETC. TO ENSURE A C OMPLETE 'LIKE NEW INSTALLATI ON OF ALL RELOCATED MATERI ALS. NOTIF Y ARCHITECT OF A NY DISC REPANCIES SY MBOLS 0- X Y J X Y WALL TYPE: REFER TO W ALL TYPE SCHEDULE ROOM NUMBER: X = ROOM NAME Y = RO OM NU MBER ENLARGED DETAIL: REFER TO DETAIL NUMBER 'X' ON SHEET NUMBER 'AX' INTERIOR OR EXTERIOR ELEVATION: REFER TO ELEVATION NU MBER 'X' ON SHEET NUMBER 'AX' BUILDING OR W ALL SECTION: REFER TO BUILDING OR WALL SECTION NUMBER 'X' ON SHEET NUMBER 'AX' DOOR NUMBER: REFER TO DOOR SCHEDULE KEYED N OTE: REFER TO NOTE 'X' ON INDIVIDUAL PLANS ELEVATION HEIGHT M ARKER: 'X' = ITEM = HEIGHT INTERIOR OR EXTERIOR WINDOW TYPE ARCHITECTU RE INTERIOR DESIGN 3 2013 INSIDE OUTSIDE A RCHITECTURE, INC. Lea E. K angas 18601 152nd A VE N DAY TON, MN 55327 763-428-5870 BJ BAAS PROJECT Complete Eye Care Medi na, MN CO NTE NTS TITLE SHEET CODE SUMMAR Y CERTIFIC ATIO N I hereby certify that this pla n, specificatio n or report was prepared by me or under my direct supervisio n a nd that I am a duly Lice nsed Professio nal Architect under the laws of the State of Mi nnesota. L4e- State Registratio n # 26203 Date 05-9-2013 T1 * COPYRIGHT 2013 C. This pla n is c opyrighted and shall he used only for the building sh own a nd is not to be copied or reproduced without writte n permission fr om Inside Outside Architecture, Inc . N 0,INLETPROTECTION (3 EA) OSILT F EN CE (300 LF) OCONCRETE WASHOUT AREA q41°-/: TUM/NODS OUS CURB OCONSTRUCT 6' 1:12 RAMP W ITH 1:10 WINGS O CONSTRUCT 5' 1:12 RAMP W ITH 1:10 W IN GS G CUT IN 8x6 W YE 90' of 6" SCHEDULE 40 PVC @ 5.0% 6" WET TAP W/ VALVE 8 71' of 6" DIP (INCL 3— 45° BENDS) O B612 CURB & GUTTER (160 LF) eB612 CUR B & GUTTER (OUTFALL) 163 LF 11 CUT IN 6x 6 TEE, 8' OF 6" DIP HYD W/ VALVE 0. POST INDICATOR VALVE 13 REMOVE AND R EPLACE BITUM IN IOUS INK IN D NOTE: ALL SPOT ELEVATIONS ARE GU TTE RLINE OR PAVING GRADES SEE ARCH ITECT PLAN FOR ADDITIONAL DIMENSION S `.,ro06,99.96,cm.sm9,9 -9ea. , v-e.mu 9057 .,, CST w 3 E GRA PHIC SCALE (m FEET ) MAINTAIN ACCESS TO EXISTING BUILDING AT ALL TI MES Erosion Pr eventi on Practices D escription of co nstructio n pha sing, veg etati ve buffer strips , horizo ntal slope gr ading, a nd other co nstructio n pr actices to be used to mi nimiz e er osio n: Stage the s ail dist urbi ng activiti es to mi nimi ze the amount of dist urbed soil pri or to stabiliz ation. Dist urbed ar eas will be consid er ed stabilized wh en cov ered with materials such os a nch ored m ul ch, stoked so d, riprop, wo od fib er blank et, or other materi als that pre vent e ro sion from occurring. G rass s eeding alo ne will not be considered st abiliz atio n. Disturb only those areas where p roposed co ntours and ele vations are shown to diff er from the e xisti ng and whe re removals and other operati ons are noted. Spe cial a rea s of the proj ect site th at ore not to be disturbed by co nstructio n acti vity or e noted on th e pl an. In stall wood fibe r bla nk et wh ere show n on the pl an to p rovid e temp orary erosi on protecti on . Description of temporary er osion pr ot ectio n or p erm ane nt cov er to be used f or exposed positiv e sl op es withi n 200 lineal f eet of a su rf ace wat er (str eam, lake, pond, ma rsh, wetl and, r eservoir, spri ng, riv er, storm water basi n, storm water drai nage sy stem, wat erw ays, wate r cou rses, a nd irrigati on system whether surfa ce water is natur al or artifi cial, p ubli c or p ri vate with ma xim um time an exposed s oil ar ea ca n remain exposed when the a rea is not actively bei ng w orke d: Provide year round stabilizati on to the ab ove me ntion ed are as in a ccorda nc e with th e following table .: Ste epne ss of sl ope ( H:V) Gre ater than 3:1 J:1 thr ough 10:1 Less than 10:1 Maximum E xpo sure Dur ation Whe n Areo Is Not Actively W ork ed 7 Days 14 D ays 14 Days Description of p ractices to be used to st abilize the normal wetted perimeter of d rainag e or diversio n ditches within 200 lineal feet of the property edge or point of di scharg e to a surfac e w ater within 24 hou rs of connecti ng th e ditch to th e su rface wat er: I nst all seed, f ertiliz er, and disc —anchor ed m ul ch or t emp or ar y w ood fiber bl ank et in ditch es and sw ai ns within 24 h ours of connecting th e dit ch or swale to the surfa ce water where sh ow n on the pla n in accord ance with th e details . Description of other erosion p re vention pr actice s to be used: Install the specified energy di ssipati on method, such os riprop a nd ge otextil e f ab ric, at pip e o utlets within 24 hours of i nstallatio n. Permane ntly s eed di st urb ed a rea s p ri or to end of seedi ng d otes specified by MnDDT. S ediment Contr ol Pr actic es Descriptio n of sedim ent contr ol p ractices to be used to minimi ze sediment s from entering surface w aters, incl uding c urb and g utter systems and storm drai n inlets: Perm anent s edim ent control pr actices to be used on this project consist of sedime ntati on b asin s. Tempor ary sedime nt co ntr ol pr acti ces to be used ore silt fe nce, cul vert inlet p rote cti on, sto rm sewer inl et pr ot ectio n, stone pod e xits, concr ete washout a rea, ditch che cks, and, if ne ces sary, st reet swe eping. Ovraaa PAST. MST. OP POC O P OST O ff SWF (Ao,we x Awl MAW DUTY NCH ROM SAS OPEC N"DE YM s-i PrIWOOKEI TCTIT '1.11.01 8.00111C1-0171 I.P(17 NATURAL SO S NOTE SUMO. UPONOM TO met' W. WON HO E A.STEM �,S :w ,,.ET .. SLT FENCE NOES: • 'MMCO CC MODEL OR APPROVED EQU AL TO MATCH CASTING • S.LI FENCE/FABRIC NOT ALLO WED TO DE USED AS INLET PROTECTION a i c m tn z 0 fax 763-689-6681 Cd a TO TO TO N COMPLET E EYE CAR E GRADING & D RAINAGE PLAN MEDINA, MINNESOTA Cl J N PLANTING REQUIREMENTS TREES : OVERSTORY DE CIDU OUS TR EES 2-I/2- DIAMETER MEASURED 4' FROM TH E BASE AT P LANTIN G OR NAMENTAL TREES 2 DIAM ETER MEASURED 4' FROM THE BA SE AT PLANTING TR EE QUAN TITY REQUIREMENTS -PER PREVIOUSLY APPROVED PLAN SH RUB REQUIREMENTS SUPPLEMENTAL SHRUBS: M INIM UM SPREAD OF 24 INCHES AT PLANTING. PLANTING COMPUTATIONS TREES EXISTING 0 PR OPO SED J (OVERSTORY) 7 (ORNAMENTAL) SHRUBS EX ISTIN G O PR OP OSED J2 ALL GR EEN SPACE SHALL BE IR RIGATED. IRRIGATION PLAN BY OTHERS. w E S GRAPHIC SCALE ( IN FEET ) BITUMINOUS PANNG -111-111-1 I _I I -I I -I I-1 111111111—IIHI��/011�ik I —'"— BARN MULC H PL ANTING SOIL 1 - r II —III —III = I 1=111=1 I IE5 1 11 / _-111 11— -I 11-1 1-111 111=1' DECIDUOUS TREE PIANING DETAIL NOT TO S CALE SET R OOTB .41 ON UNDISTURBED EARTH COLE QTY COMM C8J/BDTANICN_NAME S E SJAONGQC Fes, FallgoldAsh /Raxinusnigra'Fallgold' 25' E8 ASS -ON') an 1.. Bu r Oak/ Cu ercusmaxoca rpa 25' FB ASS -C AN PFC 2 R ofuson Oab/ Malu s'Pro fuson' 1 .5' BB ASS -ON') Sr 4 Spring Slo w Crab/ M al us'Q ring &lad 1.5' 138 ASS-Id✓IN R S✓ 1 Fbd SDIendor Qab / M alus'Fird SDI ender' 1.5' BB ASS-IOAN MA) 12 M aney.Lniper / Juniperuschi nenss'Maneyl' 36 S= RD., FOT 4-0' QC TAY 8 Taunton Yew/ Torus medil Taunton 24'S4;0.,F OT 4-0' 0.0 LL H 6 Umeliqit HydraTgeal Fydrax ,)eapaniculatatimelight' 24' HE, F OT 5-0' O.0 NFS 6 Neo n Flash Soires/ Sol raeajaponic a'Neon H all' 24'14T ., RJT 3-0' O.0 N OTE ALL OTHER PE RVIOUS AREAS S HALL RE SODDED BARK MULCH TO EXTE NT OF LOWER LI MBS 1-1 1 1-111-1 1 1=111-111-1 — 111--1 I��=111=1 1 1=111=111=111= I —I I I —III —III III III III III 1 1 1—I I CONIF ERO US IRE RANTING ING OETM NOT TO SUL E TOPSOIL LOOSENED SUBSOIL (NOTE: MIN. 10 FT. BEYOND TREE ALL DIRECTIONS) PLANTI NG SOIL SET ROOTBALL ON UNDISTURBED EARTH O AL ti 0 1I MEDINA, MINNESOTA C3 I ®SITE PLAN KEYNOTES ' \ / - - A PROPERTY LINE - S EE CI VIL B. SETB ACK LI NE - SEE CIVIL C. BITUMINOUS PARKING/ DRIVE D. WHITE PAINTED STRIPING - TYPICAL E. CONCRETE CURB F. CONC RETE SIDE WALK G. ACCESSIBLE CU RB RAMP H. SOD, SEED OR NATURAL AREA (SEE CIVIL) I. CONCRETE STO OP WITH MASO NR Y FO UNDATIO N TO F ROST DEPTH J. PREF ORME D C ONCRETE SPLAS H BLOCK - MINIMUM LEN GTH DE TYPICAL AT ALL DOW NSPOUT LOCATIONS K. ACCESSIBLE PARKING SI GN - SEE 2/AS L. UTILITY EASE MENT - SEE CIVIL N. ACCESS L ADIA GONAL STRIPI NG N. UNIVERS AL ACCESSIBILITY SYMBOL PAI NTED WITH BLUE GENERAL SITE PLAN NOTES __ / / _ _ - `'INFORMATION `' '' / _ - -_-7 ' / J `, -"/ / / 1. SEE CIVIL D RAWINGS AND CONSTR UCTION DETAILS F OR ADDITIONAL 2. THE GENER AL CONTR ACTOR SHALL VERIFY E XACT LO CATI ON OF ALL SITE UTILITIES INCL UDI NG SHUT- OFF VALVES. SWIT CHES, ETC. AND THEIR ABILIT Y TO SH UT OFF P ROPE RLY IN CASE OF AN E MERGENCY / — - MUNICIPAL CODE PROPOSED _/ ` - _ --- B / - / --1 --, / , - / - / / / - / / D E r \ -- , D - _ , - \\ \ _ \ I\ / /7/- 1 --` � /,/// / '- l / L _ __- N / ' / , / ( PICA ) / / L / � ` `lf- / PARKIN- / / ZONE: CH -RR REAR Y ARD SETBACK: ADJ USTED TO ZERO EXCEPT 10' UTILIT Y EASMENT FR ONT Y ARD SET BACK: 25 FT SIDE YARD SETBACK: 15 FT AND 28 FT SIDE YARD SETBACK: 15 FT REAR YARD SETBACK: 0 FT DUE TO PA RKING SETB AC K: SHARED/JOINT FR ONTAGE ROA D SETB ACK PA RKING PARKING SETBACKS: 10' EXCEPT TO IMPERVIOUS SU RFACE COVERAGE: 78°h ACCOMODATE SHARED/JOINT P ARKING ACROSS A COM MON LO T LI NE BUILDIN G HEIGHT: 2To' FT I MPERVIOUS SURFACE COVERAGE: 80 a AVERAGE HEIGHT OF HIGHEST R OOF PE R CODE) MAX BUILDIN G HEIGHT: 30 FT / / A _ STALL , / �� • `\`� /1 / i L — - /I E' / - 1 \ / G M j I ��•,� (DI - CENTER ON STAL L / a_- ' / / I.- / /` / .-0. AS REQUIRED BYESSI 1 IN ACCESSIBLE / _• �� y / / / w / l l� •^ F'/ 0/00 �`����� ` \ STALLSEVERY STALLS (B UT NOT LESS THAN 1) MUST BE VAN ACCESSIBLE.PROVIDE /[`_ / /0 / / /► r RE. SIGNS AS SIGNS / jj' t� / / H / / 59'.g. / / • / , / / ` / / •� d / E ICS4'. �- DISABLED PA RKIN G NAVE SIGN BACKGROUND BLUE W/WH1TE LETTERS AGR APHICS `� / / '`1` ' / ( / / / / DISABLED PARKING STATE PER MIT ENFORCEMENT NOTICE - 1� � • / \ zB, e• / / i • ' 111 N LA....RED , ` UP TOt �N PER STATE REQUIREMENTS ` • H \� / / `, 4'-0' l CE NTER OF SIG N �- AT VAN ACCESSIBLE • /. ° , •• Q •/ , / � L • / • / / �� A \I o •-� / 25'177/4^ O •'� : NW ACCES__ �_ VAN STALLS. MOUNT AN NBELGN T ADDITI ONAL HEHA HAN DICA PPED THE HA NDICAPPED SIGN \ R AAA I O�7 QO �OQ000 \- -\� ---- - '' , \ -- 'a ' z 1,2• X 21 n• z us- GALV.STEEL P OST W(T OP CAPPED. PRIMED F OR FIELD FINISHING. CONCRETE WALK - G RO4 \ EMBED METAL C YLINDER i SLEEVE INTO CONCRETE F OOTI NG. INSER T SIG N SUPPORT P OST , GROUT AND CAUOTT ° \` TO SLCT URE OF POST TO SLEEVE. EEVE. • "I/ POURED CONCRETE F N $ G RADE L NOTE SEE KEY NOTE le ARCHITECTURAL SITE PLAN - ___J ACCESSIBLE P ARKING SIGN 1/16" =1.-o• 1 1/2" = 1,0" A RCHITECT URE INTE RIOR DESIGN INSIDE OUTSIDE ARCHITECTURE, INC. Lea E. Kangas 18601 152nd AVE N DA YTON, MN 55327 763-428-5870 BJ BAAs BUILDERS INC. PROJECT Complete Eye Care Medina, MN CO NTENTS ARCHITECTURAL SITE PL AN CERTIFICATIO N I hereby certify that this plan, specification or report was prepared by me or under my direct supervision a nd that I am a duly Licensed Pr ofessional Architect u nder the laws of the State of Minnesota. 4e -g. State Registration # 26203 Date 05-9-2013 AS COPYRIGHT 2013 4 J' This pla n is copyrighted a nd shall he used only for the building shown and is not to be copied or repr oduced without written permission from Inside Outside Architecture , Inc. 0131'4' T.O . RIDGE 30 YEAR ARCHITECTURAL HIGH DEFINITION SHINGLES WITH STAR TER STR IP QTRUSS123' -A BRG 0120'-3 ' T.O. RIDGE PRE -FINISHED M ETAL STANDING SEAM ROOFING 111'-0' �IH�J-B�i q110'-0' Y IND HEAD TH IN CUT APPLIED BRICK /02'A"1 O SILL 100' -0' NISH LOOR 23'-& dTR USS BAG COO RDINATE EXTERIOR SIGNAGE REQ UIREMENTS WITH O WNER CO NTINUOUS SH INGLE OV ER' RIDGE VEN T - TYP ALL RIDG ES THIN CUT APPLIED STONE PRECAST CONCRETE SILL NO RTH ELEVATION 1/8' = 1• -0 - / CON TIN UOUSS HINGLE OVER ' R IDG E VENT ARCHITECTUR AL ALL RIDGES 30 YEAR ARCHIHIGH DEFINITION SHINGLES WITH STARTER STRIP EXTERIOR LIGHTING - CO ORDINATE REQUIREMENTS WITH ELECTRICAL THIN CUT APPLIED STO NE 112'-0 3/4' SECON D FLOOR, PRECAST CONCRETE LINTEL WEATHER PROOF THIN CUT THIN CUT APPLIED ELECTR ICAL O UTLET- A PPLIED BR ICK STONE BASE WITH COORDINATE WITH PRECAST CON CR ETE ELECTR ICAL SILL/ CA P 11C-60 12'6 314' SECOND FLOOR 109'-0' O TRUSS BAG toT-2' WNDIDR D DECO RATIVE METAL VENT THIN CUT APPLIED STONE SEE DOOR SCHEDULE FOR EXTERIOR FIN ISH x1DO-U' �4 FINISH FLOOR EXTERIOR LIGHTING -COO RDINATE REQUIREMENTS WITH ELEC TRICAL SOUTH ELEVATION 118' = 1'-0' /// CO NTIN UOUS ' SHIN GLE O VER' RIDGE VENT - TYP ALL RIDGES 30 YEAR ARCHITEC TU RAL H IGH DEFINITION SHINGLES WITH STARTER STRIP 15A HOSE BIB - COORDINATE WITH M ECH ANICAL PVC TRI G YP BOAR D AT BO TTOM OF TRUSS TYP. SEE RCP' FO R FINISH CEILING INFORMATIO N D OUBLE 2X 6 TOP PLA TE - SEE STRUCTURAL EXTERIOR FIN ISH AS SCH ED ULED BUILDING WRAP - TAPE JOIN TS SH EATH IN G - SE E STR UCTURAL 2X6 WOOD STU DS AT 16' O.C. MAX FULL THICK BATT INSULATIO N 6 M IL (M IN) POLY VA PO R BARRIER 5/8' TYPE 'X GY P BOA RD 2X 6 TREA TED BOTTOM PLATE WITH SILL SEAL - REFER TO STRUCTURA L FOR INFO APPLY CAULK/ SEALANT AT BASE OF GYP BD AND EX TERIOR S HEA THIN G OEXTERIOR WA LL SLA B AND FOUN DATION 1 GENERAL CONSTRUCTIO N TYPE NO TES: 1. A LL WA LL TYPES SHO WN ARE LOAD OR NON -LOAD BEARING 2. ALL WALL TYPES ARE NON -RATED CONTSTRUCTION 3. INTERIOR WA LL DIMENSIO NS ARE TO FACE OF WALL FINISH UNLESS NOTED OTHERWISE CONSTRUCTION TYPES 3/4' = 1' -0' EXTERIO R LIGHTING - COORDINATE REQU IREM ENTS WITH ELECTRIC AL CEMENT BOARD SIDING PVC T RIM - SEE SECTIONS DOUBLE 27, TOP PLATE - SEE STRUCTURAL FOR ATTACHMENT REQ UIREMENTS GYP BOARD AT B.O. T RUSS - TYP SEE REFLECTED CEILING PLA N FOR FIN ISH CEILING TYPE AN D HEIGHT 5/B' TYPE 'X GYP BD. BOTH SIDES 2x4 or 28 6 WOOD STU DS AT 16' O.C. MAX 28 TREATED BO TTOM PLA TE - REFER TO STRUCTU RAL FOR ATTACHMENT REQUIREMENTS TOP OF FLO OR SUBSTRATE K>NTERIOR WALL - NON -BEARING K>NTERIOR STUDS INTERIO R WALL - BEA RING / NO N-BEARING 286 STUDS 2B INTERIO R WALL - NON-BEARING 2x4 STUDS - 1 HR RATED -GAWP 3514 4. EX TERIO R WALL DIM ENSIONS ARE TO 6. SEE STRUCTURAL DRAWING S FOR EXTERIOR FA CE OF EXTERIOR BEAR ING WA LL LOCATION S AND SHEATHING. FACE OF SH EA THING AD DITIONAL FRAM ING INFORMATION ALIGNS WITH FACE OF FOUNDA TION 5. FRAMING CONTRACTOR VERIFY STUD/WALL DEPTH REQU IRED FOR WALLS WITH PLUMBING, ELECTRICAL. ETC. NO TIFY ARCHITECT OF ANY DEPTH CHANGES REQUIRED TRUSS 109BR' -0' G PRE -FINISHED METAL G UTTER S AND DOWNSP OUTS PV C TRIM CEMEN T BOA RD SIDING PVC TRIM - SEE SECTIONS HOSE BIB - C OO RDINAT E WITH MECHANICAL C ONTINUOUS ' SH IN GLE OVER' R IDGE VE NT - TY P ALL RIDG ES 30 YEAR ARCHITECTURAL HIGH DEFIN ITION SHIN GLES WITH STARTER STRIP THIN CUT APPLIED BRICK C TRIM T HIN CUT APPLIED STONE BA SE WITH PRECAS T CO NC RETE SILL/ CA P PRE -FIN ISHED M ETAL GUTTERS AN D DO WNSPO UTS THIN CUT APPLIED STONE 1126 3/4' OSECOND FLOOR 111'-0' U BRG 110'-0' ' WN D HEAD / 4109'-0' 'TRUSS BRG 02.8' T. O. SILL 100'-0' IR ISH FLO 131'4' T.O. RIDGE CEMENT BO ARD SIDING P VC T RIM - SEE SECTIONS EAST ELEVATION 1/8' = 1'-0' TH IN CUT TH IN CUT APPLIED STON E A PPLIED BRICK BA SE WITH PRECAST CONCRETE SILL/ CAP CON TINU OUS 'SH INGLE OVER' RIDGE V ENT - TYP ALL RIDG ES 30 YEAR ARCHITECTURAL HIG H DEFINITION SHINGLES WITH STARTER STRIP CONTINUO US 'SHINGLE OVER' RIDGE VENT -T YP ALL RIDGES 30 YEA R ARCHITECTURAL HIGH DEFINITION SHING LES WITH STARTER STRIP THIN CU TPRECAST APPLIED STONE CONCRETE SILL PRE -FINISHED METAL STA ND IN G SEAM ROOFING PRECA ST CONCR ETE LIN TEL 111'-0' p TRU SS BRIT THIN CUT APPLIED BR ICK 104'-0' T.O. BASE 0 EMERG ENCY KEY (KNOX)BOX- IRED BY CO DE AN D/OR LOCAL AUTHO RITIES THIN CUT APPLIED STONE BASE WITH PRECAST CONCR ETE SILL/ CA P CONTIN UOUS 'SHINGLE OVE R' RIDGE /— VENT - TYP AT ALL RIDGES 123'6' TRUSS BRG 120-3' 0'1.0 '. RID GE 111'-0' O TRUSS BRG 109'-0' TRUSS BRG THIN CUT APPLIED BR ICK Q 102'-B' T. O. SILL 00'-0' OFINISH LOOR 2X6 DOUBLE TOP PLATE - SEE STRUCTURA L FOR AT TACHMENT RQR MN TS GY P BOA RD AT BO TTO M OF TRUSS- TYP, SEE SECTIONS SEE R EFLECTED CEILING PLA N FOR FIN ISH CE ILING TY PE AND HEIG HT - TYP SO UND BATT INSU LATION (NON-COM BUSTIBLE) 2x6 WOOD STU DS AT 16' O.C. MA X 5/8' MOISTURE RESISTAN T GYP BD. - PROVIDE CEM ENT BACKER BOARD AT PLUMBING FIXTURE WA LLS SC HEDULED FOR CERAM IC TILE 2x TREATED BO TTOM PLATE - REFER TO STRUCTURAL FOR A TTAC HMENT R EQUIR EMENTS TOP OF FLOOR SUBSTRATE 3 PLUMBING WALL VERIFY WIDTH OF WA LL REQUIRED WITH PLU MBING CONTR ACTOR FLOO R / CEILING ASSE MBLY AT SECOND FLOOR FINISH FLOOR AS SCHEDULED PLYWOOD SUBFLOOR-SEE STRUCTURAL TRUSS- SEE STRUCTURAL BATT/BLOWN I NSULATION - FULL DEPTH OF T RUSS 5/8' TYPE'S' G YP BD AT B OTTO M OF FLOOR TRUSS - TYP 30 YEA R A RCHITECTURAL H IGH DEFINITION SH INGLES WITH STARTER STRIP CONTIN UOUS ' SHINGLE OVER' RIDG E VEN T - TYP AT A LL RIDG E THIN CUT A PPLIED STONE BA SE WITH PRECAST CO NCRETE SILL/ CA P WEST ELEVATION 1/8' = 1'-0' TRIMWINS)SPANDRELGLASS CEMENT B OA RD SIDI NG WI ND OW - SEE WINDOW T YP ES PVC TRIM - SEE SECTIONS CEILING / ROOF ASSEMBLY 4 3/4 ' /2' KNEE WALL 6 ROOFING AS SC HEDULED WATER P ROTECTI ON B ARRIER , 158 FELT PAPER (MIN) - SEE SECTI ONS PLYW OOD OR OSA S HE ATHI NG - SEE STRUCT URAL DRAWINGS AIR VENT CHUTES - TYPICAL AT ALL TRUSS SPACES STARTER STRIP AND WATER PROTECTION MEMBRANE TRUSSES AT 24' O.C . - SE E STRUCTUR AL DRAWINGS INSULATION STOP R-30 MIN BATT OR BLOWN INSUL 6 MIL (MIN) V AP OR BAR RIER 5/8 ' TYPE 'X GYP BOARD - TYP SEE ROOF PLA N, SECTIONS AND DETAILS FOR ADDITIO NAL INF OR MATION 3/4' WOOD CAP 5/8' TYPE 'X ' GYP BD. BOTH SID ES 2 X4 W OOD STUDS 24 ' O.C. 30 YEAR A RCHITECTURAL HI GH DEFINITION SHINGLES WITH STARTER STRIP 121'-103/4' WND HEAD THIN CUT APPLIED STONE 112E 3/4 ' SECOND FLO OR 10 T-2' WND HEAD THIN CUT APPLIED STONE GENER AL EXTERIOR ELEVATI ON N OTES 1. DO N OT SCALE DRAWINGS FOR CONS TRUCTIO N P URPOSES. USE PLAN INFOR MATION , DIMENSIONS, DETAILS. SHOP DRAWINGS AND FIELD VERIFICATI ON. 2- REFER TO FLO OR PL AN, RO OF PLAN, AND SECTI ONS F OR ADDITION AL INFORMATION 3. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRI OR TO STARTIN G A NY W ORK. NOTIFY ARCHITECT OF DISCREPANCIES 4. PROVIDE VER TICAL CONTROL J OINTS IN STO NE A ND/O R BRICK AT LOCATIONS BY ' ME ANS AND METHODS ' REQUIRED 5. PROTECT ALL INSTALLED DOORS, WINDOWS, FRAMES. ETC FROM OTHER C ONSTRUCTION W ORK IN PROGRESS 6. ALL DOORS AND WIND OWS TO BE AS S CHEDULED . SEE FINISH SPECIFICATI ONS AND D OOR SCHEDULE FOR ADDITI ON AL INFORMATION 7. RO OF OVE RHA NGS A RE TO BE 18' FROM FACE OF SHEATHING TO FACE OF FASCIA • SEE SE CTIONS EXTERIOR ELEVATI ON LEGEND NOTE: ALL E XTERIOR MATERIAL COLORS TO BE DETERMINED BY THE ARCHITECT Iry� 111(!1 DESI GNATES APPLIE D THIN STONE DESI GNATES APPLIED THIN C UT B RICK DESIGNATES CE MENT LAP BOARD SIDING (8 ' EXPOSURE) DESI GNATES MET AL STA NDI NG SEAM ROOFING DESIGNATES ARCHITECT URAL SHI NGLES EXTERIOR MATERIALS TOTAL BUILDILNG FACADE 3.90850 FT STONE: 2204 SQ FT - 56 % BRICK: 517 SQ FT- 13 % SIDING: 709 SO FT - 18 % OPE NINGS: 478 SO FT ARCHITE CTURE INTERIOR DESIGN INSIDE OUTSIDE ARCHITECTUR E, INC. Lea E. hangas 18601 152nd A VE N DAYTON, MN 55327 763-428-5870 BJBUILDERS 1,5 PROJECT Complete Eye Care Medina, MN CONTENTS EXT ERIOR ELEVATIONS & CONST RUCTION TYPES CERTIFICATION I hereby certify that this plan, specificatio n or report was prepared by me or under my direct s upervisio n and that 1 am a duly Licensed Professional Architect under the laws of the State of Minnesota . StateRegistration # 26203 Date 05-9-2013 A3 * COPYRIG HT 2013 O* This plan is copyrighted and shall he used only f or the budding show n a nd is n ot to be copied or reproduced with out written pe rmission from Inside O utside Architecture , Inc. CONTINUOUS 'S HINGL E O VER' RIDGE VENT 131'-0' @T. O. RIDGE 123'-6' @T RUSS ERG APPLIE D THI N ST ONE RO OF TRUSSES - SEE STRUCTURAL FOR DESIGN REQUIREME NTS 112'-6 3/4• @SECON D FLO OR 11RUS1'-0' S 'TBR 109'-0' @ TRUSS BRG BATT OR BLOWN IN INSULA TION (R-30. 0 MIN. )- TYP SEE EXTERIOR ELEVATIONS AND DETAILS FOR EXTERIOR MA TERIA LS 100'-0' @FINISH FLOOR T.O. FOOTING r @SEE STRUCTURA L I BUILDLING SECTIO N 1/4" = 12 61 — EXAM ROOM OPEN TO BUSINESS OFFICE LANDI NG FRAMING - SEE ST RUCTUR AL CORRIDOR 4" CONC. SLAB -ON -GRADE OV ER 10 MIL MIN VAPOR BARRIER AND GRANULAR FILL CMU OR POURED FOU NDATION - SEE STR UCTURAL RIGID INSULATION - R-10.0 MIN. -0 ROOF TRUSSES - SEE STRUCTURAL FOR DESIGN REQUIREMENTS BATT OR BLO WN IN INSULATION (R-30.0 MIN.) TYP FLOOR JO ISTS - SEE STRUCTURAL FOR DESIGN REQUIREMENTS FILL FLR/CLG CA VITY FULL W/BLOWN IN INSULA TION - TYP 5/8" TYPE 7C GYP BD B.O . TRUSS - TYP 0 CONTINUOUS 'SHINGLE OVER" RIDGE VENT 30 Y EA R AR CHITECTURAL H IGH DEFINITION SH ING LES WITH STAR TER STRIP - 30 YEA R ARCHITE CTURAL HI GH DEFINITION SHINGLES WITH STARTER STRIP - TYP. AT ALL ROOF AREAS OOF TRUSSES - SEE STRUCTU F OR DESIG N REQUIREMENTS VENTILATIO N AIR C HUTE — B ATT OR BL OWN IN INSUL ATI ON (R-30 .0 MIN.) - TYP T. O. L ANDIN JANITO R ACT CEILING AS SCHED ULE D FINISH GYP BD WALL AS SCHEDULED 1-114• WOOD STAI R RAIL B OTH SIDES - FINISH AS SCHEDULED FLOOR JOISTS - SEE STRUCTURAL FOR DESI GN REQUIRE MEN TS PLY 5/8 ' TYPE 'X G D AND FINISH ASS i LED SELF ADHERING WATER PROTECTION M EM BRANE (48' INBOARD FROM EXTERIOR WALL FACE AT ALL \ ROOF EDGES AND 18' EITHER SIDE OF VA LLE YS) "—PREFINISH ED METAL DRIP EDGE FLASHING AT ALL ROOF EDGES • PR E -FINISHED META L OVER IX CEDAR FASCIA CO NTINUOUS PRE -FINISHED VENTILATED SOFFIT 4' CO NC. SLA B -O N -GRADE OVER 10 ML M IN VAPO R BARRIER AND GRANULAR FILL PARTIAL BUILDLING SECTION 1/2" = 1'-0• 18 RISER @627132' TO LANDING ROOF TRUSSES - SEE STRUCTURAL FOR DESIGN REQUIREM EN TS 6 B USINESS OFFICE D OOR #107 BA TT OR BLOWN IN INSULA TION (R-30.0 MIN.) - TYP V ESTIBULE R IG ID INSULATION - R10.0 M IN.- CMU OR POURED FOUNDATION - SEE STRUCTURAL P OUR ED FO OTING - S EE STRUCTURAL SELF ADHERING WATER P RO TECTION MEMBRANE (48' INB OARD F ROM E XTERI OR WALL FA CE AT ALL RO OF E DGES AND 1B' EIT HER SIDE OF VALLEYS) PREFINISHED METAL DRIP ED GE FLASHING AT ALL ROOF EDGES P RE -FI NISHED METAL OVER 1X CEDA R FASCIA PRE -FINISHED METAL GUTTE RS AND DOWNSPO UTS C ONTINUOUS PRE -FINISHED VENTILATED S OFFIT CORRIDOR ROOF T RUSSES - SEE STRUCTUR AL FOR DESIGN REQUIREMENTS ARCH SEE PLAN OPTICAL/W AITING CONTINUOUS 'SHINGLE OVER' RIDGE V ENT 30 YEAR ARCHITECTURAL HI GH DEFINITION SHINGLES WITH STARTER STRIP L urGE T.O. RIDG. TRUSS '-6-p 123BRG SELF ADHERIN G WATER PROTECTI ON MEMBR ANE (48 ' INBOARD FRO M EXTERIOR WA LL FACE AT ALL RO OF EDGES AND 18' EITHER SIDE OF V ALLEYS) PREFINISHED METAL DRIP EDGE FLASHING AT ALL ROOF EDGES PRE -FINISHED METAL OVER IX CEDAR FASCIA 30 YE AR ARCHITECTURAL HIGH DEFINm ON 2 SHINGLES WITH STA RTER STRIP —18 -J 112' T. O. SEC�DTL -600 3/4'R • 111 '-0' TRUSS RRLP 110-0' DR HEAD " PR E -FINISHED METAL VENTILA TED SOFFIT GRADE VARIES 00-0' FINISH FLOO R T. O. FOOTING SEE STRUCTURAL' { 1 l NOTE: SIM - C ONTINUOUS PRE -FI NIS HED METAL FLASHING . E XTEND 8' VERTICAL AND 6' MIN DOWN SLOPE OF ROOF 2X W OOD STUDS - SEE FL OOR PLAN AND WALL TYPES FULL T HICK BATT INS ULATI ON - R-13.0 MIN - AT FINISHED RO OM ONLY ATTIC SPACE OR FI NISH R OOM PER PLAN AND SECTIONS aO W ALL TO R OOF C ONNE CTION APPLIED NATURAL THIN STONE - HOLD BOTTOM OF STONE 2' MI N ABO VE FINIS H ROOFING MATERIAL 6 MIL ( MIN) POLY VAPOR BARRIER AT FINISHED ROO M ONLY WALL SHEATHIN G - SEE STRUCTUR AL PRE -FINISHE D MET AL STEP FL ASHI NG AT W ALL TO ROOF INTERSECTION (SEE NOTE FOR SIM CONDITION) E XTEND CONTINU OUS WATER PROTECTION MEMBRANE B' UP FACE OF W ALL SHEATHING & OUT OVER ROOF SHE ATHING FINISH ROOFING - SEE ROOF PLAN RO OF SHEATHING - SEE STR UCTUR AL ROOF TRUSSES - SEE STRUCTURAL C ONTINUOUS SHIN GLE OVER ' RIDGE VENT 30 YEAR ARCHITECTURAL HI GH DEFI NITIO N SHINGLES WITH STARTER STRIP - TYP R OOF SHE ATHING - SEE STR UCTU RAL SELF - ADHERIN G WAT ER PROTECTION ME MBRANE 48 ' INBOARD FROM EXTERI OR WALL FACE AT ALL V ROOF EDGES (AND 18' EITHE R SIDE OF VALLEYS) BATT OR BLOWN IN INSULATI ON (R-30 .0 MIN.)- TYP P OL Y VA PO R BARRIER -6 MIL MIN . FINISH CEILING AS SCHEDULED - SEE REFLECTED CEILING PLA N AND FI NISH SCHED ULE APPLIED 8' X 6' WOOD DEC OR ATIVE BEAM(S), 4' WIDE AT SIDE W ALLS) - SEE REFLECTED CEILING PL AN AND FINISH SCHEDULE S/8 ' TYPE 'X' GYP BOARD SEALANT AT PERIMETER - TYPICAL BOTH SIDES ALU MINU M WI ND OW AS SCHED ULED ALL WI NDOW RE TURNS TO MATCH WIND OW TRIM EXPANSION F OAM AT PERIMET ER - TYPI CAL AT ALL WINDOWS AND E XTERIOR D OORS GYP B OARD HEAD A ND JAMB RETURNS TYPIC AL AT ALL WINDOWS - FINISH AS SCHEDULED SILL COVER AS SCHEDULED 2 x6 STUDS WI TREATED PLATE FULL THICK BATT INSULATION - R-13.0 MIN. POLY -V APOR BA RRIER - 6 MIL MI N 5/8' TYPE GYP BOARD SEALANT -BOTH SIDES, C ONTINUOUS 4" CONC. SL AB -ON -GRADE OVER 10 MIL MIN VAPOR BARRIER AND GRA NUL AR FILL 4' • 1r2' RIGID I NSUL THERMAL BREAK RIGID INSUL ATION -R-10.0 MIN . CMU OR P OURED - F OU NDATION -SEE STRUCTUR AL 0 1 '-6' PRE -FINISHED METAL DRIP -EDGE FLASHING AT ALL ROOF EDGES PRE -FINISHED METAL OVER 1x CEDAR FASCIA PRE -FINIS HED METAL VENTILATED SOFFIT - TYP APPLIED THIN BRICK (OR STONE) - SEE E XTERI OR ELE VATIONS FOR ADDITIONAL INF ORMATI ON AIR BARRIER - TAPE JOI NTS E XTERIOR SHEATHIN G PRE -FINISHED METAL FLASHING ABOVE LINTEL B uss a 8• T G PRECAST 8' ACCENT LINTEL - SEE EXTERI OR ELEVATIONS F OR ADD'L INF ORM ATION PRE -FINISHED METAL FL ASHING BEL OW LINTEL APPLIED THIN BRICK (OR ST ONE) BEYOND - REFER TO EXTERIOR ELEVATIONS F OR ADDITIONAL INFORMATION PRE -FINISHED METAL FLASHING TO MATCH WINDOW FR AME PRE CAST SILL - CONTI NUOUS OVER APPLIED STONE BASE ONLY 102-8' T. O. SILLAPPLIED THIN STONE /AIR BARRIE R - T APE J OINTS EXTERI OR SHEATHING 2• CLEARANCE TO GRADE OR / AS RE QUIRED BY ST ONE MF R W ALL SECTION @ WINDOW 1/2" = 1'-0' GRADE VARIES Np0•.0• cwa t oo84 PREFI NISHED ME TAL FLASHING TAE FOOTING VCTVeu, ARCHITECTUR E INTERIO R DESIGN INSIDE OUTSIDE ARCHITECTURE, INC . Lea E. hangas 18601 152nd AVE N DAY TON, MN 55327 763-428-5870 BJ B AAS BUIL DERS PROJECT Complete Eye Care Medina, MN CONTE NTS BUILDING SECTI ONS AND WALL SECTION CERTIFICATIO N I hereby certify that this plan, specification or report was prepared by me or u nder my direct s upervision and that I am a duly Licensed Professional Architect under the laws of the State of Mi nnesota . State Registration # 26203 Date 05-9-2013 A4 * COPYRIGH T 2013 3* This pl an is copyrighted and shall he used only for the building shown and is not to be copied Or reproduced without written permission from Inside O utside Architect ure , Inc. ARCH ITECTURE INTERIOR DESIGN O PTICAL & WAITING 1103 I WD -1 OPTICAL DISPENSING I ISO 1 PT PTB- 0-1 VP -1 SPRINKLER RISER ROO M 30 L FP VP -1 CT -1 CT -1 CPT -2 WD -1 STAFF BREAK ROOM 1 115 I (CT-/ WD -1 CPTB- 1 PT - DOCTORS O FFICE 113 1 PT -2 CORRIDOR 1 1 PTB- -0 5 - V P-1 PT -1 RE -6 3/4 A LT FIRST FLOOR FINISH PLAN 1/4" = 1'-0" WD -1 0 1/4- 12-4 I/4. VP CPT -1 T-2 WD- -0 - LOBBY 1 101A 1 T- Al O6 JAN CONC CPT -2 VP -1 CPT -2 0-1 PT WD -1 PT- PTB- PRE-TEST RO OM 101 I REFRAC TION ROOM 1031 PTB PT - WD -1 i EXR CORRIDOR 1m I CORR IDOR 1106 I PT - WD -1 EXAM RO OM 11f6 LO GO WALL I I CPTB- LOBBY lot 1 CT -4 T-4 VESTIBULE 11001 PT CPTB-1 IR I n CPT -2 VP -1 M IR D-1 VP -1 CORRIDOR 1 122 I EXAM ROOM {-1tz l--- r�� F - LL { VISUAL FIELDS ( 116 I PTB VP -1 ICPT-2 EXAM ROOM I 120 I VP -1 CPT -2 d T WO MEN 1 123 CT -2 0 CTB-2 CT -3 EXAM ROOM 1 121 PT CPTB- M ECH 2011 ,c9E, 1 TAR 106A1 BU SIN ESS O FFICE 200 1 PT - PTA- SECOND FLOOR FINISH PLAN 1/4' = 1L0" FINISH PLAN SYMBOLS z zz XXX /// XXX XXX WALL FINISH AS SCHEDULED FLOORING FINISH AS SCHEDULED BASE AS SCHEDULED CT -4 ACCENT TILE LOCATION (6' W) FLOORING TRANSITION N OTE: SEE ROOM FINISH SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION INSIDE OUTSI DE ARCHITECTURE, INC . Lea E. hangas 18601 152nd AVE N DA YT ON, MN 55327 763-428-5870 BJ BAAS RUI LO ERS PR OJECT Complete Eye Care Medina, MN CONTE NTS FINISH PLAN CERTIFICATION I hereby certify that this plan, specification or report was prepared by me or under my direct supervisio n a nd that I am a d uly Licensed Pr ofessio nal Architect under the laws of the State of Minnesota . State Registratio n # 26203 Date 05-9-2013 A9 * COPYRIG HT 2013 0* This pla n is copyrighted and shall he used only f or the building shown a nd is n ot to be copied or reproduced without writte n permission from Inside Outside Architecture , Inc. 4 AGENDA ITEM: 8 NORTHWEST ASSOCIATED CONSULTANTS, INC. 4800 Olson Memorial Highway, Suite 202, Golden Valley, MN 55422 Telephone: 763.231 .2555 Facsimile: 763.231 .2561 planners!c.-nacplanning.com MEDINA PLANNING REPORT To: Medina Planning Commission Scott Johnson, City Administrator From: Nate Sparks Date: June 6, 2013 Meeting Date: June 11, 2013 Re: Sorley Comprehensive Plan Amendment INTRODUCTION Ned Sorley at 4200 Hillview Lane is seeking to have his rural property in the City of Medina connected to the City of Loretto sewer system. In order to do so, he has made an application for a Comprehensive Plan Amendment to be included in the Metropolitan Urban Service Area. SUBJECT SITE The Sorley property is 6 acres in size and is located on the eastern side of Hillview Lane. The western side of Hillview is within the City of Loretto, while the eastern side is within the City of Medina. The property currently has a septic system. The property is currently guided in the Comprehensive Plan as "Developing Post -2030". It is zoned Rural Residential -Urban Reserve. REQUEST & SITE CONDITIONS The applicant would like to replace the existing house which would require a new septic system. The applicant's septic contractor could not find a suitable site near the desired building site for a new septic. A new system would need to be placed in a more remote location on the western side of the property. There is a portion of the property that has steep slopes, as identified in the City's Open Space Plan as being 12 to 18% in grade. Due to this topographic condition, the applicant would need to pipe under a ravine and then pump up the hill to reach the location that is suitable for installation of a septic system. Near the driveway to this property there is a manhole where the applicant could hook up to the City of Loretto's sewer system. The applicant contends that this is a more cost effective solution than replacing the septic system. AMENDMENT REQUEST In order to allow for an unsewered property to connect to the sewer system, a Comprehensive Plan Amendment must be approved by the City. The property then would be included within the City of Medina's sewered density calculation. In this case, an amendment would need to be accompanied by an interconununity service agreement, as well. If the amendment is approved and the Cities of Loretto and Medina enter into the agreement, the applicant would be allowed to connect to the sewer system. COMPREHENSIVE PLAN POLICIES When the Comprehensive Plan was developed, the City considered land use in coordination with transportation planning and sewer availability. The City's Land Use Plan calls for incremental growth from east to west along the Highway 55 corridor in the planning periods up to 2030. The area around Loretto within the City of Medina is identified for development after the current planning period The Future Land Use Plan objectives for rural development includes the following statement as Objective #10 for the Rural Service Designation: "Urban services will not be provided to the Agricultural, Rural Residential, or Developing Post -2030 land uses during this planning cycle." This area is intended to be used as an urban reserve area for development in the Post - 2030 period. For properties on septic there is an eventual incentive to connect to sewer as septic systems require eventual replacement. Not allowing urban services within this area keeps this additional incentive for redevelopment. If the City's intent is to allow connections on a limited basis, a policy should be adopted and added to the text of the plan. DENSITY CALCULATIONS Table 5-C on page 5-11 in the Comprehensive Plan illustrates the overall net residential density for development within the planning period until the year 2030. The City is planning on providing 3599 units over 1197 net acres. This comes out to a net density of 3.01 units per acre. The Metropolitan Council requires the overall minimum net density to be 3.0 units per acre. As developments are approved, the City tracks the density to confirm that the required net density is being met. The two Enclave projects would have needed a minimum of 245 units to maintain consistency with the net density numbers but came in at 270 units. This means the City is tracking slightly ahead of its minimum unit count to balance the 3 units per acre. These extra units can be "banked" for projects where the City may wish to allow a slightly lower density than previously contemplated. This may be helpful in cases where key natural resources may be threatened by the necessary density. As mentioned, the subject site is approximately 6 acres in size but is only about 4.8 net developable acres. This proposal would add 1 unit on 4.8 net acres to the City's density table. With the extra units included in the two Enclave developments the density is about 3.03 units per acre. With one house, that would be a net loss of 14 units in the density table, thus offsetting a majority of the extra units afforded to the City with the Enclave developments. Plus, adding this 4.8 acre parcel would drop the density back down to about 3.01 units per acre and restrict future flexibility. STAFF ANALYSIS There are many cases where property owners who have parcels near the Urban Service Area wish to connect to the nearest sewer system for various reasons. In many cases, the site may not have any room for a septic system due to environmental constraints. A city must weigh the consequences of such a connection, though, as these connections are not planned for in the tables required to prove density is being maintained as required by the Metropolitan Council. When a City intends to maintain rural character by keeping density as low as possible in urban areas this means there is little margin for allowing unplanned connections. The City must cautiously connect those outside of the urban service area that are in need as to not create a density issue that would require a density offset in a manner that is not contemplated by the Comprehensive Plan. The applicant is seeking to connect to the Loretto sewer system as a means for a cost effective solution that fits with their future construction plans. While this is understandable, it does create a precedence that others may wish to follow. If this property were allowed to connect, the City's density numbers would drop down close to the originally planned 3.01 and off set over half of the units banked by the two Enclave developments. If the 8 acre parcel immediately to the north came in for the same request, the density would drop down to 2.99 units per acre and the City would be out of compliance. This would result in requiring additional density elsewhere, more so than what was contemplated when the Comprehensive Plan was adopted. Connecting a property identified as Agricultural, Rural Residential, and Developing Post - 2030 to urban services is generally inconsistent with the policies of the Comprehensive Plan. The City may wish to consider in what situations connection to such properties or similar may be acceptable to make to ensure the all situations are being treated equally and that the intent of the Comprehensive Plan is being met. STAFF RECOMMENDATION Staff recommends denial of the request for the following reasons: 1. The Comprehensive Plan does not allow for the provision of urban services to properties in the Developing Post -2030 Land Use designation. 2. The required offsets from allowing such connections would lead to the City having to increase densities in other areas. 3. Site constraints and preservation of environmental conditions in areas previously identified for development within this staging period are more appropriate uses for offsetting "banked" units. If the Planning Commission finds that this request is acceptable, any recommendation of approval shall be made with the following conditions: 1. The City Council should adopt policies regarding allowances for rural properties to connect to urban services. 2. An inter -governmental utility agreement between the Cities of Medina and Loretto should be adopted prior to the connection. ATTACHMENTS: 1) Applicant Narrative 2) Letter from Septic Designer 3) Letter from City of Loretto LOCATION MAP: Commission Members: Plan amendment request: My wife, Virginia, and I have lived In our current Medina home since 2001. Our lot is six acres and it borders the City of Loretto. (see map) We are in the planning stages of building a new home on our current lot. We intend on living in our current residence until we can occupy the new residence and then raze the old residence. We have been notified that our current septic system is not sized sufficiently to accommodate the new residence as planned. The septic designer has Indicated to us that due to soil conditions, a current septic easement and the wetland that bisects the property, they cannot find a suitable site for the larger proposed system We request your approval to connect the new home site to the City of Loretto's sewer and water system at my expense as the applicant. I have attached a signed statement from the Loretto Public Works Director, Jeff Leuer, indicating their approval of our request. -The City of Loretto operates a private system that is not affiliated with the City of Medina's (Metropolitan Council) system. -This change will not impact Medina's density numbers. Furthermore, I believe the location of our property is uniquely situated to take advantage of Loretto's generous offer. Thank you, Ned Sorley WACHHOLZ INC. 100 East Lake Street Waconia, MN 55387 952-442-9323 - Phone 612-802-2903 - Cell 952-442-1032 - Fax MINNESOTA POLLUTION CONTROL AGENCY INDIVIDUAL SEWAGE TREATMENT, SYSTEMS LICENSE NO. 18aWACHHOLZINC. WAYNE & BETTY WACHHOLZ, DESIGNER II May 8, 2013 To whom it may concern Reference: Ned Sorley 4200 Hillview Lane, Loretto, MN 55357 PID 06-118-23-41-0002 Re: Septic System for new home. On April 27 & 28, 2013, we researched the property at 4200 Hillview Lane for an acceptable site for a replacement septic treatment area. Soil borings were done to locate undisturbed soils and measurements were taken on the setbacks. The area around the current building site is not suitable for a usable septic system. Sincerely, Wayrf'e Wachholz Wachholz Inc City of Loretto 279 Medina Street North, Suite 26o • P.O. Box 207 • Loretto, MN 55359 (763) 479-4305 • Fax (763) 4?9-2665 e-matL trostnCQcLloretto.mn.us www.ci.loretto.mn.us 5/16/2013 City of Medina 2052 County Road 24 Medina, MN 55340 Commission Members: MAY 1 6 2013 I have reviewed Ned Sorley's request for approval to connect to the City of Loretto's sewer and water systems. Our system have more than enough capacity and given that Ned is willing to bear the entire expense personally, we are open to the discussions and see no reason not to proceed forward. Sincerely, )'4411 Jell Lever City of Loretto Public Works Director Mayor Kent Koch Council Members Carl Girk, Henry Pepin, John Neumann, Tom .Pedersen City Clerk Travis Rosin