Loading...
HomeMy Public PortalAboutBarracuda_MAX_ApprovalFinal_090922etropolitan St. Louis Sewer 'strict 2350 Market Street St. Louis, MO 63103-2555 (314) 768-6200 September 9, 2022 Advanced Drainage Systems, Inc. Mr. Craig Dahlgren 4640 Trueman Blvd. Hilliard, OH 43026 RE: ADS Barracuda MAX Highway Use Level (HUL) and Redevelopment Use Level (RUL) Approval within the District Mr. Dahlgren, The Metropolitan St. Louis Sewer District (MSD) is pleased to provide HUL and RUL approval for the use of the ADS Barracuda MAX HDS unit as a stand-alone water quality BMP, subject to the following provisions: The Barracuda MAX is only approved for use on public highway and roadway projects, and for redevelopment sites less than 5 acres. This approval is based upon compliance with requirements listed in MSD's Proprietary Water Quality Products and the MSD's Stormwater Management Program (Revised Jan. 2009). The Barracuda MAX must be sized such that the Maximum Treatment Flow Rate (MTFR) for the unit exceeds the Water Quality flow rate calculated for the unit's tributary area. The Barracuda MAX's approved MTFRs will be those shown in Table 1 below, to match the certified flow rates provided by the New Jersey Department of Environmental Protection (NJDEP). Procedures for calculating the Water Quality flow rate are provided in Appendix 3.10 of the Maryland Stormwater Design Manual (2000). Table 1: Barracuda MAX Models and Approved MTFRs Model Manhole Dim;; eter (ft) FR (cfs) 50% Max. Sediment Storage Vol e (f t3) Barracuda S3 MAX 3 0.85 5.89 Barracuda S4 MAX 4 1.52 10.47 Barracuda S5 MAX 5 2.37 16.36 Barracuda S6 MAX 6 3.40 23.56 Barracuda S8 MAX 8 6.08 41.89 Barracuda S10 MAX 10 9.48 65.45 • The Barracuda MAX will be configured as an off-line unit, downstream from a diversion manhole. In most cases, the BMP will be installed without the need to store the Water Quality volume upstream of the unit. • All devices shall provide a minimum sediment storage capacity of 10 cubic feet. All proprietary iids and covers should be captive components. The minimum size access hole is 30 inches in diameter. ® Confined space entry shall not be a requirement for routine maintenance. No special tools or attachments should be required to provide for routine maintenance with a vacuum pumping truck. Project specific design calculations and maintenance plans furnished by the manufacturer must be included within the project's Stormwater Management Facilities Report prepared by the consulting engineer. MSD reserves the ability to withdraw or modify this approval based on subsequent information, including information indicating that this BMP does not satisfy MSD rules, requirements, or construction specifications. Sincerely, Curtis Zurliene, PE Civil Engineer (BMP Committee Chairman) Engineering / Development Review Metropolitan St. Louis Sewer District