HomeMy Public PortalAboutLP pumpstation details-all (2023)STANDARD M.S.D. C.I. FRAME & COVER VARIES 4'-0' MIN. 6" 2'-0" f 12" 2" j\ \\ 000 PROPOSED GRADE o O e v o 0 48" DIA. ---5" ]oD 2" CLEARANCE PIPE OPENING MINIMUM(TYP) SLOT PRIVATE 1'-0" LINE 24" PIPE OPENING SLOT 2 EA. ROLLS OF 1" BUTYL ROPE SEALANT FILTER FABRIC 0o DO a o v>0 < %/ STANDARD PRECAST BASE WITH 24" HOLE.4' \ j\ �� FILTER /moo FABRIC g��� ooa oo 3/4"- 1" ��/ og �' CLEAN ROCK. eg o �\ o� ���\ 000 0 __ 000 \ /\/\/\/\/\/\/\ /\ / , /\/\////\/\, NOTE: ALL TOPS MUST BE REINFORCED. SUBMIT DESIGN FOR ALL STRUCTURE TOPS SUBJECT TO VEHICLE LOADING. F 1 FOOT OVERT PIPE FORCE MAIN 2" MAXIMUM SECTION VALVE JUNCTION BOX 2" FORCE MAIN METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 1 15" /\ VARIES 4'-0' MIN. 30"x30" HATCH ACCESS DOOR (SEE LPSSDR SECTION 3.2N) SEE NOTE i\% \Y/4\ 0> /// c v 10" o 0 O 60" DIA. ---5" ]oD 2" CLEARANCE /-PIPE OPENING MINIMUM(TYP) a SLOT Q \\ 8" 2'-O" 000 FILTER FABRIC o� o \\bp�,o \/ /oho oopo o 8cbo>*/X> ///, >7/>7/>S- -/ 5/ 3/W/, %/ ( PRIVATE 1'-0" LINE PIPE OPENING SLOT STANDARD PRECAST BASE WITH 24" 3/4" CLEAN ROCK. PROPOSED GRADE 7/\/\\\//\ �A. ROLLS OF 1" BUTYL ROPE SEALANT o1? HOLE.4'=. NOTE: ALL TOPS MUST BE REINFORCED (SUBMIT DESIGN FOR ALL STRUCTURE TOPS SUBJECT TO VEHICLE LOADING). FILTER FABRIC F 1 FOOT OVER PIPE FORCE MAIN 3" AND 4" MAXIMUM SECTION VALVE JUNCTION BOX 3" and 4" FORCE MAINS METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 2 00000000 2" PVC PIPE SCHEDULE 80 GRV X PE 2" SDR 21 PVC 2" SCHEDULE 80 PVC COUPLING 2" VICTAULIC NO. 75 FLEXIBLE COUPLING 2" VICTAULIC NO. 726 BALL VALVE 2" VICTAULIC NO. 712 CHECK VALVE 2 X 2 TEE IPS VICTAULIC NO. 20 TNM 140 2" SCHEDULE 80 SOLVENT WELD COUPLING WITH REDUCER BUSHING TO LATERAL SIZE 2" PUBLIC FORCE MAIN NOTE: THIS FORCE MAIN NEEDS TO BE OFFSET 10" CLEAR FROM THE CENTERLINE OF THE MANHOLE OPENING. PRIVATE FORCE MAIN NOTES: 1) USE STAINLESS STEEL BOLTS AT ALL FLANGED CONNECTIONS. 2) STAMPED ALUMINUM IDENTIFICATION TAGS MUST BE WIRED TO EACH VALVE. THEY ARE TO IDENTIFY THE 2" VALVES AS "MSD UPSTREAM" ,"MSD DOWNSTREAM" AND "PRIVATE SERVICE". THE ADDRESS OF THE LATERAL SHALL BE CLEARLY STAMPED ON THE PRIVATE VALVE TAG. 48" CONCRETE STRUCTURE WITH PIPE OPENING SLOTS (SEE FIGURE 1) 2" PUBLIC FORCE MAIN STANDARD MANHOLE OPENING PLAN VIEW VALVE JUNCTION BOX 2" FORCE MAIN METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 3 0 © ® 0 4" AWWA DIP GRV X PE PIPE 4" C900 PVC 4" MJ SLEEVE W/WEDGE TYPE RETAINER GLANDS 4" VICTAULIC NO. 307 TRANSITION COUPLING 4" VICTAULIC NO. 365 AWWA PLUG VALVE © 2" VICTAULIC NO. 726 BALL VALVE ® 2" VICTAULIC NO. 712 CHECK VALVE 4" PUBLIC FORCE MAIN NOTE: THIS FORCE MAIN NEEDS TO BE OFFSET 10" CLEAR FROM THE CENTERLINE OF THE ACCESS DOOR OPENING. ® 2" VICTAULIC NO. 75 FLEXIBLE COUPLING ® 4 X 2 TEE IPS VICTAULIC NO. 25 TNM 140 10 2" SCHEDULE 80 SOLVENT WELD COUPLING WITH REDUCER BUSHING TO LATERAL SIZE 11 2" SCHEDULE 80 PVC GRV X PE 12 4" VICTAULIC NO. 31 COUPLING PRIVATE FORCE MAIN 60" CONCRETE STRUCTURE WITH PIPE OPENING SLOTS (SEE FIGURE 2) 4" PUBLIC FORCE MAIN STANDARD OPENING FOR 30"x30" HATCH ACCESS DOOR (SEE LPSSDR SECTION 3.2N) NOTES: 1) USE STAINLESS STEEL BOLTS AT ALL FLANGED CONNECTIONS. 2) STAMPED ALUMINUM IDENTIFICATION TAGS MUST BE WIRED TO EACH VALVE. THEY ARE TO IDENTIFY THE 4" VALVES AS "MSD UPSTREAM" ,"MSD DOWNSTREAM" AND THE 2" VALVE AS "PRIVATE SERVICE". THE ADDRESS OF THE LATERAL SHALL BE CLEARLY STAMPED ON THE PRIVATE VALVE TAG. PLAN VIEW VALVE JUNCTION BOX 4" FORCE MAIN METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 4 10 3" PVC PIPE SCHEDULE 80 GRV X PE 02 3" SDR 21 PVC cp © © 3" SCHEDULE 80 PVC COUPLING 3" VICTAULIC NO. 307 TRANSITION COUPLING 3" VICTAULIC NO. 365 AWWA PLUG VALVE 2" VICTAULIC NO. 726 BALL VALVE 07 2" VICTAULIC NO. 712 CHECK VALVE 3" PUBLIC FORCE MAIN NOTE: THIS FORCE MAIN NEEDS TO BE OFFSET 10" CLEAR FROM THE CENTERLINE OF THE ACCESS DOOR OPENING. ® 2" VICTAULIC NO. 75 FLEXIBLE COUPLING 09 3 X 2 TEE IPS VICTAULIC NO. 25 TNM 140 10 2" SCHEDULE 80 SOLVENT WELD COUPLING WITH REDUCER BUSHING TO LATERAL SIZE 11 2" SCHEDULE 80 PVC GRV X PE PRIVATE FORCE MAIN 60" CONCRETE STRUCTURE WITH PIPE OPENING SLOTS (SEE FIGURE 2) 3" PUBLIC FORCE MAIN STANDARD OPENING FOR 30"x30" HATCH ACCESS DOOR (SEE LPSSDR SECTION 3.2N) NOTES: 1) USE STAINLESS STEEL BOLTS AT ALL FLANGED CONNECTIONS. 2) STAMPED ALUMINUM IDENTIFICATION TAGS MUST BE WIRED TO EACH VALVE. THEY ARE TO IDENTIFY THE 3" VALVES AS "MSD UPSTREAM" ,"MSD DOWNSTREAM" AND THE 2" VALVE AS "PRIVATE SERVICE". THE ADDRESS OF THE LATERAL SHALL BE CLEARLY STAMPED ON THE PRIVATE VALVE TAG. PLAN VIEW VALVE JUNCTION BOX 3" FORCE MAIN METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 5 O O 00000 2" LOCKDOWN QUICK COUPLING CAP 2" QUICK COUPLING 2" CURB STOP BALL VALVE 2" BRASS FULL FACED FLANGE 2" SOCKET FLANGE SCHEDULE 80 P.V.C. 2" SCHEDULE 80 P.V.C. FITTINGS 2" SCHEDULE 80 P.V.C. PIPE 1 1/2" x 1 1/2" x 3/8" S.S. ANGLE BRACE. NOTE: ALL TOPS MUST BE REINFORCED. (SUBMIT DESIGN FOR ALL STRUCTURE TOPS SUBJECT TO VEHICLE LOADING). STANDARD MANHOLE OPENING \\// SEE NOTE. �\ / 12" 0 4 v /4 oD 0-00) d V %A 0 4 0 p o 0 �\ io5 n 4 o D </...._ FILTER \\ FABRIC 0� (t' 0 ° o 0_ (.-C4 O t, 4' 0" I-oc 24" 00 D • 0 4� C 0 < 4a 0 PROPOSED GRADE 2 EA. ROLLS OF 1" BUTYL ROPE SEALANT. VARIES 4' MIN. V0P. 0p0 0 FILTER FABRIC 1 FOOT OVER PIPE 00g0cS 000\/ 5" f /V F 12" DO �o '0°' >0 t" 4 4 0 STANDARD PRECAST BASE WITH 24" HOLE. 3/4" - 1" CLEAN ROCK. \/ a \/\// /X/X/\/\/\/\/\/\/ /\/\ / 6" 2'-0" i EMERGENCY TRUCK CONNECTION DETAIL METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 6 r- ›. 0 cn m c C <�m D <0 rn E w rr) Z _< r 0 (n C- D N N CA z O Z o N (3)-- C) r 0 Cb N cb iN O A O • XJ c c) N 0 FORCE MAIN 30" x30" HATCHED _ ACCESS DOOR SEE NOTE. \�\ / 0 0 15" \ yp �n 60" CONCRETE , STRUCTURE Nv• / 0 0 0 " o oar FORCE MAIN 1 1/2" x 1 1/2" x 3/8" S .S. ANGLE BRACE. STANDARD OPENING FOR 30"x30" HATCH ACCESS DOOR (SEE LPSSDR SECTION 3 .2N) o p a // oa o \/ 2 EA. ROLLS OF ° 1" BUTYL ROPE SEALANT FILTER VARIES FABRIC 4' MIN. 2" AND 3" FORCE MAINS ITEM QU ANT. NO. SIZE DESCRIPTION ARI D-025 COMBINATION AIR VALVE SCHEDULE 80 P .V.C . TEE / REDUCING TEE P .V.C . COUPLING 2 2"/3"x3"x2" 4 5 6 2"/3„ 2"/3 2 "x6„ 2" x6" 8 SCHEDULE 80 P.V .C . PIPE STAINLESS STEEL PIPE NIPPLE STAINLESS STEEL BALL VALVE, 1/4 TURN (SEE LPSSDR SECTION 3.4D) STAINLESS STEEL PIPE NIPPLE STAINLESS STEEL COUPLING SOCKET TO FEMALE ADAPTER (THREADED) 9 2" 4" FORCE MAINS ITEM QUANT . SIZE N O. 2 3 2 4 5 6 7 8 PROPOSED GRADE 0a p ' 0 n 44� 1 FOOT OVER PIPE � /� STANDARD PRECAST BASE WITH 24" HOLE. V"\— FILTER ' FABRIC 3/4" — 1" oo-g_ �/ o� CLEAN ROCK. o����oo' 0 \ // /X >7/%\ \%-/>/>/>'/ ->//7/151.1K/ /\ /\\ 2'- DESCRIPTION ARI D-025 COMBINATION AIR VALVE 4"x2" D.I .P. M.J. TAPPED TEE LON G PATTERN SLEEVE MECHANI CAL JOINT ME GA -LU G DUCTILE IR ON PIPE 2"x6" STAINLESS STEEL PIPE NIPPLE STAINLESS STEEL BALL VAL VE, 1/4 TURN (SEE LPSSDR SECTI ON 3 .4D) 2"x6" STAINLESS STEEL PIPE NIPPLE STAINLESS STEEL C OUPLE 30"x30" HATCHED ACCESS DOOR STANDARD PRECAST BASE WITH 24" HOLE . MAXIMUM ROCK LEVEL . NOTE: ALL TOPS MUST BE REINFORCED (SUBMIT DESIGN FOR ALL STRUCTURE TOPS SUBJECT TO VEHICLE LOADING) . 0000000000000000 4" MJ WYE W/MEGA LUGS FOR DUCTILE IRON ON RUN AND BRANCH 4" MJ STREET (MJ X PE) 45° BEND W/MEGA LUGS FOR DUCTILE IRON 2"/3" SDR-21 P.V.C. FORCE MAIN PIPING TYPE 4" GROOVED BY PE DUCTILE IRON PIPE (VARIABLE LENGTH) 3" 1/4 TURN BALL VALVE (SEE LPSSDR SECTION 3.4B) 3" VICTAULIC STYLE 31 DUCTILE IRON COUPLING 3" VICTAULIC STYLE 60—C DUCTILE IRON CAP 2"/3" SCHEDULE 80 P.V.C. PIPE (VARIABLE LENGTH) 2"/3" SCHEDULE 80 P.V.C. SOCKET COUPLING 4" DUCTILE IRON PIPE 6" GRADE RING 4"x2"/4"x3" VICTAULIC STYLE 50 DUCTILE IRON CONCENTRIC REDUCER 4" VICTAULIC STYLE 307 DUCTILE IRON TRANSISITION COUPLING 2"/3" VICTAULIC STYLE 75 DUCTILE IRON FLEXIBLE COUPLING 4"x3" DUCTILE IRON REDUCER 4" VICTAULIC STYLE 31 DUCTILE IRON COUPLING EXISTING GRADE. STANDARD M.S.D. C.I. FRAME & COVER. FILTER FABRIC LOW PRESSURE SEWER SYSTEM CLEAN —OUT DETAIL 2" AND 3" FORCE MAINS METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. D.H.R. Ch. S.D.K. 2023 FIGURE 8