Loading...
HomeMy Public PortalAbout12-8390 Federal Emergency Management Agency Reimbursement in the amount of 5,495.43 Sponsored by: City Manager Resolution No. 12-8390 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF OPA-LOCKA, FLORIDA,AUTHORIZING THE CITY MANAGER TO PAY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) REIMBURSEMENT IN THE AMOUNT OF FIVE THOUSAND FOUR HUNDRED NINETY-FIVE DOLLARS AND FORTY THREE CENTS($5,495.43)FOR OVERPAYMENTS MADE IN RELATION TO HURRICANE WILMA (FEMA-DR-1609 FL, PW#2280), PAYABLE FROM ACCOUNT NO. 45-541493; PROVIDING FOR INCORPORATION OF RECITALS;PROVIDING FOR AN EFFECTIVE DATE. WHEREAS,the City of Opa-locka received money from Federal Emergency Management Agency(FEMA) for costs incurred relative to Hurricane Wilma; and WHEREAS, FEMA performed a final audit of the City's records, and determined that the City of Opa-locka was paid $183,495.43, but was only eligible to receive $177,558.46, an overpayment of$5,495.43; and WHEREAS,the City of Opa-locka received an invoice from FEMA for reimbursement of the overpayments made in relation to Hurricane Wilma; and WHEREAS, the City Commission of the City of Opa-locka desires to authorize the City Manager to reimburse Five Thousand Four Hundred Ninety-five Dollars and Forty -three Cents ($5,495.43) to FEMA, for overpayment of Hurricane Wilma expenses, (FEMA-DR-1609 FL, PW#2280). NOW,THEREFORE,BE IT DULY RESOLVED BY THE CITY COMMISSION OF THE CITY OF OPA-LOCKA, FLORIDA: Section 1. The recitals to the preamble herein are incorporated by reference. Resolution No. 12-8390 Section 2. The City Commission of the City of Opa-locka hereby authorizes the City Manager to reimburse FEMA in the amount of Five Thousand Four Hundred Ninety-five Dollars and Forty-three Cents ($5,495.43), for overpayment of expenses related to Hurricane Wilma (FEMA-DR-1609 FL, PW#2280), payable from Account No. 45-541493. Section 3. This resolution shall take effect immediately upon adoption. PASSED AND ADOPTED this 11th day of April, 2012. r---, / YRA AYLOR • YOR to: 'ttest C . kAkek. 4.0Z411, J i anna Flores Interim City Clerk Approved as r: fo and legal •r iency: iA - ALA Jos' IF• . 1"e ler Ci Atto 'ley Moved by: COMMISSIONER H MES Seconded by: VICE MAYOR JOH ON Commission Vote: 5-0 Commissioner Holmes: YES Commissioner Miller: YES Commissioner Tydus: YES Vice-Mayor Johnson: YES Mayor Taylor: YES Q er 44, 9 v � s cfr'ws'owwt0 City of Opa-Locka Agenda Cover Memo Commission Meeting 04/11/2012 Item Type: Resolution Ordinance Other Date: X (EnterX in box) Fiscal Impact: Ordinance Reading: 1st Reading 2nd Reading (Enter X in box) Yes No (Enter X in box) X Public Hearing: Yes No Yes No (EnterX in box) X X Funding Source: (Enter Fund&Dept) Advertising Requirement: Yes No (Enter Acct No.) 45-541493 (EnterX in box) X Contract/P.O. Required: Yes No RFP/RFQ/Bid#: (Enter X in box) X N/A Strategic Plan Related Yes No Strategic Plan Priority Area: Strategic Plan Obj./Strategy: (list the (Enter X in box) X specific objective/strategy this item will address) Enhance Organizational El Bus.&Economic Dev p Public Safety O Quality of Education Qual.of Life&City Image 0 Communication LI Sponsor Name City Manager Department: City Manager Short Title: A RESOLUTION OF THE CITY OF OPA-LOCKA, FLORIDA AUTHORIZING THE CITY MANAGER TO PAY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) INVOICE IN THE AMOUNT OF $5,495.43 FOR A REIMBURSEMENT OF OVERPAYMENTS MADE IN RELATION TO HURRICANE WILMA, FEMA-DR-1609 FL, PW#2280. Staff Summary: FEMA performed a final audit of the City's records related to Hurricane Wilma, FEMA-DR-1609 FL, Project Worksheet (PW) # 2280. This PW was written to address hurricane damage at City Parks. It was determined that FEMA paid the City $183,053.89; however eligible expenses totaled $177,558.46, a difference of $5,495.43. Proposed Action: Recommend Approval. Attachment: 1. FEMA invoice in the amount of$5,495.43 2. Project Worksheet Report, PW#2280 it LOC o 6t f yr J. 4 i_ i//may► K •...,,:,,C,-,7t11----::: glievehia" Memorandum TO: Mayor Myra L. Taylor Vice-Mayor Dorothy Johnson Commissioner Ti i' ;thy Holmes Commissioner . all Miller Commissione Rose Tydus FROM: Bryan Finnie, %' Manager DATE: April 2, ,,,04 RE: PAYMENT OF FEMA INVOICE Request: A RESOLUTION OF THE CITY OF OPA-LOCKA, FLORIDA AUTHORIZING THE CITY MANAGER TO PAY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) INVOICE IN THE AMOUNT OF $5,495.43 FOR A REIMBURSEMENT OF OVERPAYMENTS MADE IN RELATION TO HURRICANE WILMA. Description: Hurricane Wilma was the most intense tropical cyclone ever recorded in the Atlantic basin. Wilma was the twenty-second storm (including the subtropical storm discovered in reanalysis), thirteenth hurricane, sixth major hurricane, and fourth Category 5 hurricane of the record-breaking 2005 season. Wilma made several landfalls, with the most destructive effects felt in the Yucatan Peninsula of Mexico, Cuba, and the U.S. State of Florida. At least 62 deaths were reported, and damage is estimated at $29.1 billion (2005 USD, $34.6 billion 2012 USD), $20.6 billion (2005 USD, $24.5 billion 2012 USD) of which occurred in the United States alone. As a result, Wilma is ranked among the top five most costly hurricanes ever recorded in the Atlantic and the fourth most costly storm in United States history. (Wikipedia) One area of damage in the City of Opa-locka was to the parks systems. The storm knocked over 75-foot light poles, blew out over 100 fixtures at all three parks, destroyed flood lights and wiring between poles. Financial Impact: $5,495.43 payable from account #45-541493. Will be included in upcoming FY 2011- 2012 budget amendment. Implementation Timeline: Immediately. Legislative History: none Recommendation(s): Staff recommends approval. Analysis: FEMA performed a final audit of the City's records related to Hurricane Wilma, FEMA-DR- 1609 FL, Project Worksheet (PW) #2280. This PW was written to address hurricane damage at City Parks. It was determined that FEMA paid the City $183,053.89; however eligible expenses totaled$177,558.46, a difference of$5,495.43. Attachments: (1) Invoice from FEMA (2) Project Worksheet Report(FEMA-FL-DR-1609), PW#2280 PREPARED BY: Faye Douglas,Budget Administrator 31 :7r 4 STATE OF FLORIDA DIVISION OF EMERGENCY MANAGEMENT RICK SCOTT BRYAN W.KOON Governor Director March 23, 2012 Opa Locka, City of . Attn: Starex Smith 780 Fisherman St. 4th Floor Opa Locka, FL 33054 Re: Overpayment Dear Mr. Smith: The attached invoice is in reference to an overpayment for Hurricane Wilma: FEMA-DR-1609 FL. (see attachment) • Please remit to the State of Florida: $5,495.43 at: • Division of Emergency Management 5900 Lake Ellenor Drive Orlando, FL 32809-4634 Attention: Renee Singh, Deputy State Public Assistance Officer of Finance Please contact Renee Singh via e-mail, Renee.SinghCrr�em.mvflorida.com or by phone .at 407-858-2761, should you have any questions or need any additional information. Respectfully, CIAL i 1 . . 1 / / Charles Shinkle • Deputy Bureau Chief Florida Division of Emergency Management Attachment: CS/tca FLORIDA RECOVERY OFFICE • DIVISION HEADQUARTERS • STATELOGISTICSRESPONSECENTER 5900 Lake Ellenor Drive 2555 Shumard Oak Boulevard 2702 Directors Row Orlando, FL 32809-4634 Tallahassee, FL 32399-2100 Orlando, FL 32809-5631 407-858-2761. Tel 850-413-9969-Fax: 850-488-1016 www.FloridaDisaster.orri • INVOICE STATE OF FLORIDA Division of Em ergency M anagem ent Date:Mar23, 2012 Invoke# :29 To: Opa-Locka,City of(FIPS: 086-51650-00) 780 Fisheim an Street 4th floor Opa-locka,FL 33054 Disaster PW# Federal Share Admin State Share Line Item Total 1609 I 2280 I $5,441.02 I $54.41 I $0.00 $5,495.43 SubTotal $5,495.43 Make checks payable to State of Florida for total amount of: $5,495.43 LIL ilbrda Publ.r Ass:star c.e, 5900 ta " RTioi:D re,0 rtallo, FL 32809.4 634 Phon,::: (4 07) 8 58-2761 IF(ax (4 G 7 858-442 9 .LETiee thigh@ till n yfbril.a 1 Payment#29 Project 2280 FEMA-1609-DR-FL 086-51650-00 Payment #29: Project 2280 (L - Cat G) Opa-Locka, City of Eligible Federal Admin State Obligated & Approved Version 0(Large)-Initial Obligation. $181,241.48 $135,931.11 $1,812.41 n/a System Administrator-Jun 14,2006 Version 1 (Large)-Federal Share Change $0.00 $27,186.22 $0.00 n/a System Administrator-Jan 18,2007 Version 2(Large)-Version Modification $0.00 $0.00 $0.00 n/a System Administrator-Jun 17,2007 Version 3(Large) -Federal Share Change $0.00 $18,124.15 $0.00 n/a System Administrator-Jun 19,2007 Version 4(Large)-Eligible Amount Change ($5,441.02) ($5,441.02) ($54.41) n/a Renee Singh-Aug 15,2011 $175,800.46 . $175,800.46 $1,758.00 $0.00 Justified by RFRs (100.0%) RFR#1 -Expense Approval $181,241.48 Melissa Vallejo-Sep 29, 2006 Advance#1 -Undocumented Advance $181,241.48 Bill Owens-Jul 21,2006 Reversal of Overrun -$5,441.02 $175,800.46 $175,800.46 $1,758.00 $0.00 Previous Payments Payment#21 $135,931.11 $1,812.42 $0.00 Velma Ellis-Jul 24,2006 Payment#22 $0.00 $0.00 $22,655.19 Velma Ellis-Sep 29,2006 Payment#23 $27,186.22 $0.00 ($13,593.11) Aaron Harden-Feb 20,2007 Payment#25 $0.00 $0.00 $0.00 System Administrator-Aug 13, 2007 Payment#27 $18,124.15 $0.00 ($9,062.07) Rami ltani-Dec 6,2007 Payment#28 $0.00 ($0.01) ($0.01) Leasha Clay-Wilson-Dec 3,2008 —$181,241.48 - $1,812.41 — $0.00 Adjustments + $0.00 + $0.00 + $0.00 - This Payment ($5,441.02) ($54.41) $0.00 This payment leaves a balance of$0.00. Payment calculations as at Mar 22,2012. Printed from FloridaPA.org on Mar 22,2012 at 3:27 PM. PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF SUBDIVISION INF TYPE INF • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC CATEGORY G.Recreational or Other COUNTY MIAMI-DADE FUNDING OPTION COST SHARE 1 STD PROJECT NO. 799 PROJECT TITLE RECREATIONAL OR OTHER PROJECTED CMPLTN DT 10/23/2009 ACTUAL CMPLTN DT WORK COMPLETE AS OF 04/30/2010 100 % ELIGIBILITY Yes AMOUNT ELIG$-5,441.02 FEDERAL SHARE $-5,441.02 PRIORITY Normal BEGIN DESIGN DT BEGIN CONSTR DT -PW REVIEWER DATA REVIEWER NAME DATE END DESIGN DT END CONSTR DT INITIAL REVIEW JOHNSTON MILLER,KATHY 07/14/2011 PREPARER WILLIE HAYNES FINAL REVIEW CAMPBELL SHIER,LISA 07/19/2011 ROLE PO DATA SOURCE STATE WILLIE HAYNES MT PROP 0 Yes• No VALIDATED • Yes 0 No DATE OBLGTD 07/21/2011 PACKAGE DATE 07/21/2011 PNP QUESTIONS 0 Yes• No STATE RVWD 0 Yes 0 No PACKAGE ID 631 ATTACH • Yes 0 No Does the Scope of Work change the pre-disaster conditions at the site? 0 Yes • No 0 Unsure Special Considerations issues included? • Yes 0 No 0 Unsure Is there insurance coverage on this facility? 0 Yes • No 0 Unsure Hazard Mitigation proposal included? 0 Yes • No 0 Unsure Page 1 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE C INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC SITE NUMBER 1 of 1 FACILITY NAME LIGHTING AT CITY PARKS Latitude 25.90518 ADDRESS Longitude-80.25317 CITY OPA-LOCKA STATE FL ZIP Was this site previously damaged? O Yes O No • Unsure SITE NUMBER 1 -LOCATION CITY PARKS,OPA LOCKA, FL CITY HALL BASE BALL FIELD TENNIS COURTS AT INGRAM PARK BASKETBALL COURTS AT INGRAM PARK BASEBALL FIELD AT INGRAM PARK Page 2 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SITE NUMBER 1 -DAMAGE DIMENSIONS AND DESCRIPTION CITY HALL BASE BALL FIELD DURING THE EVENT OF HURRICANE WILMA,HIGH WINDS: KNOCKED OVER TWO-75 FEET TALL POLES, BLOWING OUT 82-1500W FIXTURES, DAMAGING 1000 FEET OF#2 QUADRUPLES,AND 1000 FEET OF#2 TPX WIRING AT THE CITY HALL BASEBALL FIELD. TENNIS COURTS AT INGRAM PARK AT INGRAM PARK HIGH WINDS AND FLYING DEBRIS SHATTERED 16-1500W DIRECTIONAL FIXTURES AROUND THE TENNIS COURTS AND BASKETBALL COURTS AT INGRAM PARK: 8-1500W FIXTURES AROUND THE BASKETBALL COURT. BASEBALL FIELD AT INGRAM PARK: HIGH WINDS ALSO DOWNED 3 POLES NEAR THE BASEBALL COURT DAMAGING A 35 FEET PCSO POLE, 3-250W COPRA LIGHTS, THE WIRING BETWEEN THE POLES, DESTROYING 5-1500W FLOOD LIGHTS,AND DAMAGING 44 OF THE 1500W LIGHTS. Page 3 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE Q INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SITE NUMBER 1-SCOPE OF WORK ***********"WORK TO BE COMPLETED************* CITY HALL BASE BALL FIELD -PROVIDE,DRILL HOLES FOR,AND INSTALL 2-75 FEET WOOD POLES -PROVIDE AND INSTALL 82-1500W FIXTURES -PROVIDE AND PULL 1000 FEET#2 QUADRUPLES AND 1000 FEET#2 TPX -CHECK SAFETY SYSTEMS -REMOVE AND DISPOSE OF ALL DAMAGED FACILITIES TENNIS COURTS AT INGRAM PARK -PROVIDE AND INSTALL 16-1500W DIRECTIONAL FIXTURES -REPAIR ANY DAMAGE IN POWER SOURCE -CHECK SAFETY SYSTEM -REMOVE ALL DAMAGED FIXTURES BASKETBALL COURTS AT INGRAM PARK -PROVIDE AND INSTALL 9-1500W FIXTURES -REPAIR ANY DAMAGE IN POWER SOURCE -CHECK SAFETY SYSTEM -REMOVE ALL DAMAGED FIXTURES BASEBALL FIELD AT INGRAM PARK -PROVIDE AND INSTALL 35 INCH PCSO POLE -PROVIDE AND MOUNT 3-250W COPRA LIGHTS FOR PARKING LOT -REPAIR THE INTACT 44-1500W FIXTURES -PROVIDE AND PULL#2 TPX WIRES -PROVIDE AND INSTALL 6-1500W FLOOD LIGHTS IN 3 POLES -PROVIDE, DRILL HOLES FOR,AND INSTALL 3 POLES DAMAGE MITIGATION HAS BEEN CONSIDERED, HOWEVER NONE IS EFFECTIVE POSSIBLE MITIGATION TO POLES. A.PLESHKO **VERSION 4- Page 4 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE O INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SITE NUMBER 1-SCOPE OF WORK ***THIS VERSION IS FOR FINAL INSPECTION AND CLOSEOUT OF PW#2280 CV4*** THIS PROJECT WORKSHEET WAS WRITTEN TO REIMBURSE THE APPLICANT FOR EXPENSES ASSOCIATED WITH ELIGIBLE CATEGORY G,PERMANENT REPAIRS WORK, IN RESPONSE TO HURRICANE WILMA-DR#1609.ALL WORK WAS COMPLETED FROM 10/24/05 TO 04/30/08 AS SELECTED BY THE APPLICANT FOR 100%FUNDING.CLOSEOUT VERSION 4 TO THIS PROJECT GRANT HAS BEEN WRITTEN TO ACCOUNT FOR THE CHANGES IN PROJECT GRANT COSTS,AND TO BRING FINAL CLOSURE UPON APPROVAL AND OBLIGATION. DOCUMENTATION WAS PROVIDED BY: FAYE DOUGLAS,ASSISTANT FINANCE DIRECTOR,(305)953-2831,FDOUGLAS @OPALOCKAFL.GOV A SITE VISIT ON 04/5/2011 AT CITY OF OPA-LOCKA WAS ATTENDED BY: WILLIE HAYNESSTATE PAC,(407)398-5102 WILLIE.HAYNES @EM.MYFLORIDA.COM THIS CLOSEOUT VERSION IS WRITTEN TO DE-OBLIGATE FUNDING IN THE AMOUNT OF$(5,441.02)FOR STORM DAMAGE REPAIRS TO THE CITY'S PARKS LIGHTING SYSTEMS,BASED UPON A FINAL RECONCILIATION CONDUCTED ON 4/5/11.THE NET UNDER-RUN IS DUE TO ADJUSTMENTS REQUIRED DUE TO THE ORIGINAL PW WRITTEN ON ESTIMATES,THIS CLOSEOUT VERSION IS WRITTEN ON ACTUAL VALIDATED COSTS. CONTRACT: OBLIGATED AMOUNT=$181,241.48 ELIGIBLE AMOUNT=$175,800.46 THE CLOSEOUT TEAM REVIEWED THE APPLICANT'S PROCUREMENT POLICY AND VERIFIED THAT ALL CONDITIONS WERE MET.THE TEAM REVIEWED 100%OF CONTRACTOR'S INVOICES AND VERIFIED ENDORSED CHECKS/PROOF OF PAYMENT PAID ON 100%OF THE INVOICES. 1. ENTERPRISE ELECTRICAL CONTRACTORS WAS SELECTED TO PERFORM THE LIGHTING SYSTEM REPAIRS. A TOTAL OF 18 OF 18 INVOICES WERE PRESENTED AND VALIDATED. Page 5 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SITE NUMBER 1 -SCOPE OF WORK 2.SHERBONY PARK WAS IDENTIFIED AS CITY HALL PARK IN THE ORIGINAL PW AND THEREFORE ALL COST FOR CITY HALL PARK ARE FOR AND WILL BE IDENTIFIED AS SHERBONY PARK. 3. THE TEAM VERIFIED ALL WORK ITEMS WERE COMPLETED WITHIN THE ALLOWABLE TIME FOR COMPLETION.VERIFIED PERIOD OF WORK WAS FROM 10/24/2005 TO 9/30/2008;HOWEVER,THOUGH THE DEADLINE FOR PERMANENT WORK WAS 4/23/2007,THE STATE OF FLORIDA GRANTED A 48 MONTH TIME EXTENSION FOR ALL SUB-GRANTEES OF DR-1609. 4.AN INTERIM INSPECTION SEPARATED COSTS FOR SEGAL PARK THAT WERE CAPTURED IN VERSION 0 AS COSTS FOR INGRAM PARK BASEBALL FIELD. FINAL INSPECTION RESULTS: ALL CONTRACTS WERE REVIEWED AND FOUND COMPLIANT WITH THE APPLICANT CONTRACT PROCUREMENT PROCEDURES, COPIES ARE ATTACHED.A SITE INSPECTION WAS CONDUCTED FOR THE CAT G PROJECT ON 4/05/2011.THE FIRST FINAL INSPECTION AND SUBSEQUENT FRR(DSI)SUBMISSION HAD UNDOCUMENTED DISCREPANCIES.ACCORDING THE SUB-GRANTEE, THE STORM RELATED DAMAGES AT SEGAL PARK WERE INADVERTENTLY INCLUDED IN VERSION 0 AS IDENTIFIED IN INGRAM PARK. THE CITY SUBMITTED A REQUEST FOR INTERIM INSPECTION TO RECTIFY THE MISAPPROPRIATED COSTS FOR SEGAL PARK.(SEE ATTACHED REQUEST FOR INTERIM INSPECTION)THE STATE OF FLORIDA CONDUCTED THE INTERIM INSPECTION AND SUBMITTED A VERSION THAT IDENTIFIES THE DAMAGES AND SUBSEQUENT REPAIRS PERFORMED AT SEGAL PARK. THE INTERIM VERSION SEPARATES THE SEGAL PARK COSTS THAT WERE CAPTURED IN VERSION 0 UNDER THE INGRAM PARK BASEBALL FIELD COSTS.THE INTERIM INSPECTION INCLUDED AN ENTERPRISE ELECTRICAL CONTRACTING INVOICE#3206 FOR WORK AT INGRAM PARK NOT INCLUDED IN THE SCOPE OF WORK(REPAIR OF THE WIRING TO A WATER PUMP)THAT THE CITY CLAIMS, THE WATER PUMP IS PART OF THE ELECTRICAL SYSTEM AT THE PARK AND SUPPORTS THE PARKS PROGRAMS. IT WAS PART OF THE STORM RELATED DAMAGE."(SEE ATTACHED E-MAIL) EXPLANATION OF UNDER-RUN: THE ORIGINAL PW COSTS WERE BASED ON BID DOCUMENTS.THE CITY PROVIDED INVOICES FOR ACTUAL COSTS THAT TOTALED LESS THAN THE ORIGINAL ESTIMATED BIDS CREATING AN UNDER-RUN IN THE AMOUNT OF($5,441.02). Page 6 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE O INF SUBDIVISION NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SITE NUMBER 1 -SCOPE OF WORK VARIOUS INVOICES WERE SUBMITTED AS CLAIMED COSTS BUT ARE DEEMED INELIGIBLE FOR THE FOLLOWING REASONS: -INVOICE#632 IS DEEMED INELIGIBLE FOR EXTRA WORK NOT RELATED TO THE STORM EVENT PER 44 CFR 206.223(A)1 IN THE AMOUNT OF($1,886.45). -INVOICE#2306 IS DETERMINED TO BE INELIGIBLE FOR EXTRA WORK NOT RELATED TO THE STORM EVENT PER 44 CFR 206.223(A)1 IN THE AMOUNT OF($443.03). -ENTERPRISE ELECTRICAL CONTRACTING INVOICE#2408 IS FOR NEW WORK PERFORMED RECREATION DEPARTMENT WAS NOT LOCATED AT OR NEAR SEGAL PARK IN THE AMOUNT OF($329.17). -ENTERPRISE ELECTRICAL CONTRACTING INVOICE#3538 IS FOR WORK AT INGRAM PARK NOT INCLUDED IN THE SCOPE OF WORK (VANDALISM)IN THE AMOUNT OF($1,834.18). -ENTERPRISE ELECTRICAL CONTRACTING INVOICE#4181 IS FOR NEW WORK PERFORMED AT SHERBONDY PARK NOT INCLUDED IN THE SCOPE OF WORK IN THE AMOUNT OF($6,000.00). -ENTERPRISE ELECTRICAL CONTRACTING INVOICE#4682 IS FOR CHECKING AND TROUBLESHOOTING ELECTRICAL SYSTEM PERFORMED AT INGRAM PARK LONG PAST THE REASONABLE PERMANENT WORK DEADLINE FOR THIS DECLARATION IN THE AMOUNT OF($1,128.53). -ENTERPRISE ELECTRICAL CONTRACTING INVOICE#4897 IS FOR SURVEYING THE ELECTRICAL SYSTEM PERFORMED AT SHERBONDY PARK LONG PAST THE REASONABLE PERMANENT WORK DEADLINE FOR THIS DECLARATION IN THE AMOUNT OF ($1,206.83). THE INVOICES LISTED ABOVE TOTAL MORE THAN THE UNDER-RUN AMOUNT BECAUSE THEY SHOULD NOT HAVE BEEN INCLUDED AS COSTS ASSOCIATED WITH THIS PW;HOWEVER THEY ARE DOCUMENTED IN THE VERACITY OF FULL DISCLOSURE OF INFORMATION. SPECIAL CONSIDERATIONS: INSURANCE: THE APPLICANT DOES NOT HAVE STORAGE FOR THIS TYPE OF EXPOSURE.THERE ARE NO INSURANCE PROCEEDS TO BE DEDUCTED.AS PER 44 CFR 206.257(B)(1),INSURANCE IS NOT REASONABLY AVAILABLE,ADEQUATE,AND NECESSARY TO PROTECT AGAINST FUTURE LOSS TO SUCH PROPERTY FROM WINDSTORM. ENVIRONMENTAL: THE SUB-GRANTEE HAS CONFIRMED THERE WERE NO HAZARDOUS MATERIALS,ASBESTOS OR LEAD PAINT FOUND DURING ASSESSMENT AND REPAIR.ALL MATERIALS WERE DISPOSED OF IN ACCORDANCE WITH FDEP SOLID WASTE REQUIREMENTS. HAZARD MITIGATION: NO MITIGATION IS APPLICABLE TO THIS CAT G PROJECT. CONCLUSION: ALL PREVIOUS VERSIONS OF THIS PROJECT WORKSHEET HAVE BEEN OBLIGATED IN A TOTAL AMOUNT OF$181,241.48. INSPECTION OF THE SUPPORTING DOCUMENTATION HAS SUBSTANTIATED A TOTAL ELIGIBLE AMOUNT OF$175,800.46 RESULTING IN AN UNDER-RUN OF$5,441.02.WE BELIEVE THESE TOTALS TO BE TRUE AND ACCURATE;THEREFORE,WE RECOMMEND THAT THIS VERSION(CV4)SERVE AS FRR FOR THIS PROJECT WORKSHEET. Page 7 of 16 PROJtCT WORKSHEET REPORT ``"" DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC COST ESTIMATE ITEM;VSN COBB MATERIAL AND/OR DESCRIPTION UOM QTY [ UNIT PRICE I COST 1 1 0 0000 WORK TO BE COMPLETED 0 0 $.00 $0.00 2 0 9025 CITY HALL BASE BALL FIELD LS 1 $112,808.00 $112,808.00 3 0 9025 TENNIS COURT AT INGRAM PARK LS 1 $20,444.00 $20,444.00 4 0 9025 BASKETBALL COURTS AT INGRAM PARK LS 1 $12,120.11 $12,120.11 5 0 9025 BASEBALL FIELDS AT INGRAM PARK LS 1 $35,869.37 $35,869.37 6 4 0000 VERSION FOR FINAL INSPECTION AND CLOSEOUT 00 0 $.00 $0.00 7 4 9999 DEOBLIGATE PREVIOUS VERSION CITY HALL LS 1 $-112,808.00 ($112,808.00) BASEBALL FIELD 8 4 9999 DEOBLIGATE PREVIOUS VERSION TENNIS COURT AT LS 1 $-20,444.00 ($20,444.00) INGRAM PARK 9 4 9999 DEOBLIGATE PREVIOUS VERSION BASKETBALL LS 1 $-12,120.11 ($12,120.11) COURTS AT INGRAM PARK 10 4 9999 DEOBLIGATE PREVIOUS VERSION BASEBALL FIELDS LS 1 $-24,532.50 ($24,532.50) AT INGRAM PARK 11 4 9999 DEOBLIGATE PREVIOUS VERSION SEGAL LS 1 $-11,336.87 ($11,336.87) RECREATIONAL PARK 12 4 9025 CONTRACT LS 1 $175,800.46 $175,800.46 Eligible Amounts: Total(this version) ($5,441.02) Total Oblig To Date $175,800.46 Unobligated+Obligated $175,800.46 Federal Share for Obligated and Unobligated $175,800.46 SPECIAL CONSIDERATIONS 1 Does the damaged facility or item of work have insurance coverage and/or is it an insurable risk 0 Yes • No 0 Unsure (e.g.,buildings,equipment,vehicles,etc.)? 2 Is the damaged facility located within a floodplain or coastal high hazard area and/or does it have an • Yes 0 No 0 Unsure impact on a floodplain or wetland? COMMENTS: 09/27/2010 12:44:04 THIS AREA IS WITHIN THE 100 YEAR FLOOD PLAIN,SEE FIRM 12025C0090J COMMENTS: 09/27/2010 13:00:17 LOCATION IS ON FEMA MAP:12025C0090J 3 Is the damaged facility or item of work located within or adjacent to a Coastal Barrier Resource 0 Yes • No 0 Unsure System Unit or an Otherwise Protected Area? 4 Will the proposed facility repairs/reconstruction change the pre-disaster conditions(e.g.,footprint, 0 Yes • No 0 Unsure material,location,capacity,use or function)? Page 8 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC SPECIAL CONSIDERATIONS 5 Does the applicant have a hazard mitigation proposal or would the applicant like technical O Yes • No 0 Unsure assistance for a hazard mitigation proposal? COMMENTS: 09/27/2010 12:44:04 MITIGATION OF POLES MAYBE POSSIBLE.EA PRPYCH,MITIGATION SPECIALIST. COMMENTS: 09/27/2010 12:44:04 2/8/06-APPLICANT INDICATED THE ORIGINAL WOODEN POLES WERE OLD AND WEAK AND THAT THE NEW WOODEN POLES PROVIDED MEET CODE AND SHOULD PROVIDE SUFFICIENT MITIGATION.A.PLESHKO,MIT.SPEC. 6 Is the damaged facility on the National Register of Historic Places or the state historic listing?Is it O Yes • No 0 Unsure older than 50 years?Are there more,similar buildings near the site? 7 Are there any pristine or undisturbed areas on,or near,the project site?Are there large tracts of O Yes • No O Unsure forestland? 8 Are there any hazardous materials at or adjacent to the damaged facility and/or item of work? 0 Yes • No 0 Unsure 9 Are there any other environmental or controversial issues associated with the damaged facility O Yes • No 0 Unsure and/or item of work? Page 9 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF SUBDIVISION INF TYPE INF • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC FLOODPLAIN Applicant Type (A) Facility 1.Is the project in a Wetland(Swamp,marsh,etc.)? (B) No STEP 1 2.Is the project on a FIA/FEMA map? Yes Map No. 12025C0090J 3.Total PW estimated cost of restoration (C) 4.Has this project been damaged by flooding previously? (D) Unknown Location 500-year Floodplain Has a flood insurance payment(s)ever been received? When? 5.Land Use Upstream 5.Land Use Downstream Urban(Developed) Urban(Developed) 6.Recommendation Restore Facility w/o MT Federal Inspector IVAN D.JOHNSON Date 02/10/2006 00:00:00 7.Justification For Floodway or Coastal High Hazard Area Location (E) Functionally Dependent Use 8.Initial Notice Determination Step 2 Cumulative (A)Degree of Public Need Essential (B)No.of Individuals Affected Repair/Replacement Relocate No FEMA Action (C)Potential for Controversy Ye Yes Yes (D)Potential Impact Yes Yes Yes 9.Are the following alternatives feasible?(Base your decision on the considerations listed below) (A)Engineering (C)Economic Aspects (E)Legal Constraints Restore Facility w/o MT STEP 3 1 2 3 4 5 6 Minimize danger to lives In Y• N p Y • N Io Y • N Q Y• N Q Y • N r Y o I• Minimize damage to facility Y • N po Y • N rD Y e N Q Y O N Y N p Y• 1, Minimize damage elsewhere p Y• N p Y • N p Y• N In Y• N In Y • N In Y o t Reduce support of floodplain or wetland N Y• N p Y • N In Y • N $0 Y• N $0 Y • N p Y • t Restore floodplain values p Y• N $0 Y • N p Y• N $0 Y • N p Y• N In Y Maintain or improve economic resources 10 Y• N $0 Y • N $0 Y• N $0 Y• N Y 5 N $Q Y • I' Maintain or improve social resources $0 Y • N In Y • N $ Y• N In Y • N Y N Y• f 10.Feasible Alternatives that will minimize adverse impacts ❑ 1.Relocated outside the base floodplain ,Z 5.Restore w/o MT O 2.Restore w/MT [i 6.No action(Disapprove project) rj 3.Transfer function to another facility 0 7.Suspend for further investigation • 4.Reduce scope of work 11. Re-evaluate the alternatives.Select the number of the chosen alternative from STEP 6 STEP 3. If none,select"None"and indicate suspension in STEP 8 with a"7". 5 12. Final Notice Determination First check if any of the following apply : Critical Action ✓I P A/ ti nn nnn Page 10 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC O Repair is substantial improvement STEP 7 O Previously damaged in declared flooded disaster Cumulative Final Notice O Located in floodway or coastal high hazard area An individual first notice was issued O Past flood insurance payment(s) FEMA Reviewer Date STEP 8 JOHNSON, IVAN 02/10/2006 00:00:00 0 1 O 20 30 4. 50 60 7 Page 11 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC ENVIRONMENTAL-All Environmental Review is complete. Project must be implemented in accordance with conditions list below. Laws/EOs Status Coastal Barriers Resources Act(CBRA) Gen Revw/NA Clean Water Act(CWA) Gen Revw/NA Coastal Zone Management Act(CZMA) Gen Revw/NA Endangered Species Act(ESA) Gen Revw/NA Fish and Wildlife Coordination Act(FWCA) Gen Revw/NA National Historic Preservation Act(NHPA) Gen Revw/NA Clean Air Act(CAA) Gen Revw/NA State Hazardous Materials and Solid Waste Laws Gen Revw/NA See Condition E.O. 11988:Floodplains Completed 02/10/2006-Per 44 CFR Part 9.5(d)(4),project has been reviewed for repairs to damaged structures and facilities>$100,000 or>50%of the cosi of reconstruction.Disaster-wide initial public notice was published state wide on November 11 through 21,2005. Project has limited potential to cause long-term adverse direct or indirect effects to the floodplain or wetlands. Ivan D.Johnson Floodplain Spec. E.O. 11990:Wetlands Gen Revw/NA E.O. 12898:Environmental Justice for Low Income and Minority Populations Gen Revw/NA NEPA Level of Review-NEPA review is complete. The project is Statutorily Excluded.-JMARIANO Required Conditions Resulting from Environmental Review Monitoring Monitoring Completed Law Name Conditions Required Entered By Required Date By State Hazardous Materials and Solid Waste Laws NNOPLIS ❑ 00/00/0000 09/29/10-The subgrantee has confirmed there were no hazardous materials,asbestos,or lead paint found during assessment and repair.All materials were dipsoed of in accordance with FDEP solid waste requirements. H.Batson,EHP Specialist 2/1/06-Applicant is responsible to ensure potential hazardous materials,such as PCB containing ballasts,shall be removed and disposed of in accordance with compliance requirements of the FL DEP. Page 12 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC Standard Conditions 1. Any change to the approved scope of work will require re-evaluation for compliance with NEPA and other Laws and Executive Orders. 2. This review does not address all federal,state and local requirements.Acceptance of federal funding requires recipient to comply with all federal,state and local laws. Failure to obtain all appropriate federal,state and local environmental permits and clearances may jeopardize federal funding. 3. If ground disturbing activities occur during construction,applicant will monitor ground disturbance and if any potential archeological resources are discovered,will immediately cease construction in that area and notify the State and FEMA. Page 13 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC GENERAL COMMENTS 01/31/06-PHOTOS W/HARD COPY-DISC PHOTOS ATTACHED-KU/DT NO PW GENERAL COMMENTS PAGE WITH PW. SPECIAL CONSIDERATIONS INCLUDED: FLOODPLAIN REVIEW 2/1/06-THIS PW IS WRITTEN FOR COSTS INCURRED DURING THE AFTERMATH OF HURRICANE WILMA.AFTER REVIEWING THE CITY'S FIELD BASE BIDS, IT APPEARS THAT SOME OF THE DAMAGES INCLUDED COULD BE PREDISASTER DAMAGES SUCH AS THE ROTTEN WOODEN POLES WHICH WOULD HAVE ROTTEN OVER THE YEARS DUE TO AGING AND WEATHER ELEMENTS.OTHER ITEMS MAY BE QUESTIONABLE BUT COULD BE RESEARCHED AND DETERMINED DURING CLOSEOUT OR AUDIT.VIEWING THE TENNIS COURT, BASEBALL FIELD AND BASKETBALL COURT BIDS FOR INGRAM PARK,SOME OF THE ITEMS THERE COULD ALSO BE QUESTIONABLE. (PLEASE REFER TO FILE FOR DETERMINATION AS TO WHAT IS ACCEPTABLE AND QUESTIONED AT CLOSEOUT). FROM THE PHOTOS SUBMITTED,THE FIELDS APPEARS TO BE WORN FROM MANY YEARS OF USAGE AND AGE.I HAVE DEEMED THESE FACILITIES AS BEING ELIGIBLE UNTIL FURTHER RESEARCH HAS BEEN PERFORMED TO DETERMINE STATUS OF ELIGIBILITY. DOCUMENT RETENTION: COMPLETE RECORDS AND COST DOCUMENTATION FOR ALL APPROVED WORK MUST BE MAINTAINED FOR AT LEAST 5 YEARS FROM THE DATE THE LAST PROJECT WAS COMPLETED OR FROM THE DATE FINAL PAYMENT WAS RECEIVED, WHICHEVER IS LATER.EBELL/QC REVIEW 2/8/06-SOME MITIGATION HAS BEEN ACCOMPLISHED DURING THE REPAIRS.NO OTHER MITIGATION OPPORTUNITIES. ANDY PLESHKO,MITIGATION SPECIALIST. 02/10/2006- PER 44 CFR PART 9.5(D)(4),PROJECT HAS BEEN REVIEWED FOR REPAIRS TO DAMAGED STRUCTURES AND FACILITIES >$100,000 OR>50%OF THE COST OF RECONSTRUCTION. DISASTER-WIDE INITIAL PUBLIC NOTICE WAS PUBLISHED STATE WIDE ON NOVEMBER 11 THROUGH 21,2005. PROJECT HAS LIMITED POTENTIAL TO CAUSE LONG-TERM ADVERSE DIRECT OR INDIRECT EFFECTS TO THE FLOODPLAIN OR WETLANDS. IVAN D.JOHNSON FLOODPLAIN SPEC. 6/8/06-INSURANCE CONSIDERATIONS. APPLICANT DOES NOT HAVE INSURANCE ON FOR THESE ITEMS. THERE ARE NO INSURANCE PROCEEDS TO BE DEDUCTED. AS PER 44 CFR 2 Page 14 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 0 REC GENERAL COMMENTS 06.253(B)(1),INSURANCE IS NOT REASONABLY AVAILABLE,ADEQUATE,AND NECESSARY,TO PROTECT AGAINST FUTURE LOSS TO SUCH PROPERTY FROM WINDSTORM.THE APPLICANT'S INSURANCE PURCHASE REQUIREMENT FOR THIS DISASTER IS WAIVED. RALPH DELLINGER,INSURANCE SPECIALIST,B ***VERSION FOR FINAL INSPECTION AND CLOSEOUT*** SPECIAL CONSIDERATIONS: FLOODPLAIN 09/27/2010-PHOTOS W/PW HARD COPY/SCANNED DOCS WILL ATTACH ON FINAL. JAMARIANO/GMS 09/29/2010-OUT OF INITIAL-KLJOHNSTON 4/25/2011 -ON HOLD PENDING RE-WRITE FOR WORK NOT IN SCOPE AND POSSIBLY NOT STORM RELATED.KJOHNSTON 6/2/2011 -FRR REWRITTEN TO EXCLUDE INELIGBILBE WORK/SITES.OUT OF INITIAL KJOHNSTON EHP REIVEW 09/29/10-THE SUBGRANTEE HAS CONFIRMED THERE WERE NO HAZARDOUS MATERIALS,ASBESOS OR LEAD PAINT FOUND DURING ASSESSMENT AND REPAIR.ALL MATERIALS WERE DIPSOSED OF IN ACCORDANCE EITH FDEP SOLID WASTE REQUIREMENTS.ALL EHP ISSUES HAVE BEEN ADDRESSED.H.BATSON,EHP SPECIALIST 11/3/10 INSURANCE CONSIDERATIONS: PW HAS BEEN PLACED ON HOLD TILL INSURANCE PROCEEDS ARE RESOLVED WITH THE FLORIDA LEAGUE OF CITIES/FLORIDA MUNICIPAL INSURANCE TRUST. RALPH DELLINGER. 2/4/11 -INSURANCE CONSIDERATIONS:APPLICANT DOES NOT HAVE INSURANCE FOR THIS TYPE EXPOSURE. THERE ARE NO INSURANCE PROCEEDS TO BE DEDUCTED. AS PER 44 CFR 206.253(B)(1), INSURANCE IS NOT REASONABLY AVAILABLE,ADEQUATE, AND NECESSARY,TO PROTECT AGAINST FUTURE LOSS TO SUCH PROPERTY FROM WINDSTORM. RALPH DELLINGER, INSURANCE SPECIALIST REVISION 05/23/11 ***VERSION FOR FINAL INSPECTION AND CLOSEOUT PW#2280 SC4*** SPECIAL CONSIDERATIONS: FLOODPLAIN (INSURANCE COMMENT) (ENVIRONMENTAL COMMENT) NO PHOTOS W/HARD COPY-NO DISC PHOTOS ATTACHED-NO DISC W/PW ENTERED BY R.LANDIS-GRANTS MONITORING SPECIALIST ON 05/23/11. Page 15 of 16 PROJECT WORKSHEET REPORT DECLARATION NO.FEMA-FL-DR1609 PREPARED DATE 04/12/2011 FIPS NO. 086-51650-00 REPORT DATE 07/22/2011 11:59 APPLICANT NAME OPA-LOCKA,CITY OF INF TYPE 0 INF SUBDIVISION • NON-INF FEMA PW# 2280 VSN 4 REF# 2280SC4 O REC GENERAL COMMENTS REVISION 07-12-11 --------- ***VERSION FOR FINAL INSPECTION AND CLOSEOUT PW#2280 SC4*** SPECIAL CONSIDERATIONS: FLOODPLAIN (INSURANCE COMMENT) (ENVIRONMENTAL COMMENT) NO PHOTOS W/HARD COPY-NO DISC PHOTOS ATTACHED-NO DISC W/PW ENTERED BY R.LANDIS-GRANTS MONITORING SPECIALIST ON 07/12/11. 7/14/2011-OUT OF INITIAL KJOHNSTON PW REQUIRED REVIEWS REVIEW ASSIGNED DATE DATE REVIEW STATUS RECOMMENDATION REVIEWER REVIEWER SUBMITTED REVIEWED Initial Complete Eligible kjohnst2 09/27/2010 09/29/2010 Initial Complete Eligible kjohnst2 07/12/2011 07/14/2011 Initial Complete Eligible kjohnst2 09/29/2010 04/26/2011 Insurance Complete Eligible rdilling 09/29/2010 02/04/2011 STATE Complete Eligible jzgodzin 07/14/2011 07/19/2011 DEBRIS Complete Eligible kjohnst2 04/26/2011 06/02/2011 Floodplain Management Complete Eligible kmorriso 04/26/2011 05/25/2011 STATE Complete Eligible jzgodzin 09/29/2010 02/07/2011 Environmental Complete Eligible hbatsonl 09/29/2010 09/29/2010 Final Complete Eligible Icampbel 07/19/2011 07/19/2011 Page 16 of 16