Loading...
HomeMy Public PortalAbout10-0074 Parker T FIXCW° , CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 02 -22 -2010 PERMIT #: 100074 WORK DESCRIPTION SWIMMING POOL WORK LOCATION 1805 CHATHAM OWNER NAME GREGORY M. PARKER ADDRESS 19 E GORDON ST CITY, ST, ZIP SAVANNAH GA 31401 -4925 PHONE NUMBER CONTRACTOR NAME YEAR ROUND POOL COMPANY INC ADDRESS 1484 FORDING ISLAND ROAD CITY STATE ZIP BLUFFTON SC 29910 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 50.00 PROPERTY IDENTIFICATION # PROJECT VALUATION $68,240.00 TOTAL BALANCE DUE: $ 50.00 It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire, soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: _/ • 4 A A / A L o 0 0‘ j b u% (T P.O. Box 2749 - 403 Butler Avenue , T bee Island, Georgia 31328 �oO� W L1S vs o Y g d :c1 In O 4- se4- C 0 1 ra 1-4" (912) 786 -4573 - FAX (912) 786 -9539 www .cityoftybee.org l„) hO✓Yx°"OwvLrot G CITY OF TYBEE ISLAND, GEORGIA APPLICATION FOR BUILDING PERMIT 10\ L J A ID-o 0 '7 4 eik 0 Location: !XS liletlkthain ,,(4, PIN # 2-1-Q - 13 -coq NAME ADDRESS TELEPHONE cpta, Owner D-taciA kt 6+ 12) 84 - I (p 1 63 MitttaA A i Architect or Engineer Building LAW reek h eC 38,( A, c c.. Contractor ittuitl-0-1 (.5e, c...2 qg Y (Check all that apply) I Repair Li Residential Footprint Changes Renovation ['Single Family – POOL. — Discovery E Minor Addition Duplex Demolition Substantial Addition fl Multi-Family Other E Commercial Details of Project: SiLe.-, la an Uc LcL Estimated Cost of Construction: $ & 0 Construction Type (Enter appropriate number) (1) Wood Frame (4) Masonry (6) Other (please specify) (2) Wood & Masonry (5) Steel & Masonry Paiv /6pa ni (3) Brick Veneer Proposed use: Remarks: ATTACH A COPY OF THE CERTIFIED ELEVATION SURVEY OF LOT and complete the following information based on the construction drawings and site plan: # Units – # Bedrooms – # Bathrooms – Lot Area 33 4 .pJ 5 " Living space (total sq. ft.) – # Off-street parking spaces Trees located & listed on site plan Access: QW,1efS pepe)i-ti Driveway — (ft.) With culvert? — With swale? - Setbacks: Front Rear Sides (L) (R) # Stories --- Height — Vertical distance measured from the average adjacent grade of the building to the extreme high point of the building, exclusive of chimneys, heating units, ventilation ducts, air conditioning units, elevators, and similar appurtances. Ei - rne-ne au_4( 04 C Cat 751'7 - 4 - A 57 Lice-Bs6- _Pct.eCe4V7S1- 40 9 During construction: On -site restroom facilities will be provided through N /A On -site waste and debris containers will be provided by zr a i toto, Construction debris will be disposed by 1i06z(, by me s of 'T✓iu I understand that I must comply with zoning, flood damage control, building, fire, shore protections and wetlands ordinances, FEMA regulations and all applicable codes and regulations. I understand that the lot must be staked out and that the stakes will be inspected to ensure that the setback requirements are met. I understand also that a certified plot plan showing elevation must be attached to this application and that an as -built elevation certification is due as soon as the habitable floor level is established. Drainage: I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected. I accept responsibility for any corrective action that may be necessary to restore drainage impaired by this permitted construction. Date: 2,. /fry/f(? Signature of Applicant: ] /p Note: A permit normally takes 7 to 10 days to process. The following is to be completed by City personnel: Zoning certification NFIP Flood Zone Approved rezoning/variance? Street address and number: New Existing Is it in compliance with City map? If not, has street name and/or number been reported to MPC? FEMA Certification attached State Energy Code Affidavit attached Utilities and Public Works: Describe any unusual finding(s) Access to building site Distance to water main tap site Distance to sewer stub site Water meter size Stou i drainage Approvals: Signature Date FEES Zoning Administrator Permit Code Enforcement Officer `Ji,4". /r Inspections Water /Sewer ' Water Tap Storm/Drainage Sewer Stub Inspections Aid to Const. City Manager TOTAL Dianne Otto From: Ann Thran [Ann.Thran @dnr.state.ga.us] Sent: Friday, February 19, 2010 10:26 AM To: Dianne Otto Subject: Re: 1805 Chatham Ave. Attachments: parkerjd verification.pdf It is out of our jurisdiction and will not require a Shore Protection Act permit from us. I am attaching the jd verification letter from last May, it references the survey you sent. thanks ann »> Dianne Otto <Dotto(Jcityoftybee.org> 2/19/2010 8:40 AM »> Ann: Attached is a scalable survey and a proposed swimming pool location for 1805 Chatham Avenue. I hope to visit the site today to get a look at it. Do you see any DNR issues? Dianne K. Otto, CFM City of Tybee Island phone 912.786.4573 ext. 136 fax 912.786.9539 From: oceprinter @oce.com [mailto:oceprinter @ oce.com] Sent: Friday, February 19, 2010 9:28 AM To: Dianne Otto Subject: Scan from Economic Development ************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e -mail if you have received this e -mail by mistake and delete this e -mail from your system. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of The City of Tybee Island. The recipient should check this email and any attachments for the presence of viruses. The City of Tybee Island accepts no liability for any damage caused by any virus transmitted by this email. City of Tybee Island P.O. Box 2749 Tybee Island, GA 31328 ************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1 • GEORGIA DEPARTMENT OF NATURAL RESOURCES COASTAL RESOURCES DIVISION May 27, 2009 Kelie Parker 222 Drayton Street Savannah, Georgia 31410 RE: Shore Protection Act Jurisdiction Line, 1805 Chatham Avenue, Lot C of a Resubdivision of Inlet Lots 21 -27, Ward 6, Tybee Island, Atlantic Ocean, Chatham County, Georgia. Dear Ms. Parker, Thank you for submitting the certified survey dated 5 -21 -2009 by J. Whitley Reynolds, Registered Surveyor Number 2249 for 1805 Chatham Avenue, Tybee Island, Atlantic Ocean, Chatham County, Georgia. Staff has reviewed the survey and finds the current Shore Protection Act Jurisdiction Line and Toe of Landward Dune, accurately depict the jurisdiction of the state under the Shore Protection Act O.C.G.A. 12 -5 -230 et seq. Please feel free to contact me at (912) 617 -6310 if I can be of further assistance. Sincerely, Ann Thaan Permit Coordinator Ecological Services Section ONE CONSRRVAIION WAY BRUNSWICK, GEORGIA 31520 (912) 264 -7218 FAx: (912) 262 -3143 CoasLalGaDNR.org I qgCl,a an, GFoa A c-r 63 DEPARTMENT OF NATURAL RESOURCES S U.1 f9.% poo J COASTAL RESOURCES DIVISION May 27, 2009 Kelie Parker 222 Drayton Street Savannah, Georgia 31410 RE: Shore Protection Act Jurisdiction Line, 1805 Chatham Avenue, Lot C of a Resubdivision of Inlet Lots 21 -27, Ward 6, Tybee Island, Atlantic Ocean, Chatham County, Georgia. Dear Ms. Parker, Thank you for submitting the certified survey dated 5-21 -2009 by J. Whitley Reynolds, Registered Surveyor Number 2249 for 1805 Chatham Avenue, Tybee Island, Atlantic Ocean, Chatham County, Georgia. Staff has reviewed the survey and finds the current Shore Protection Act Jurisdiction Line and Toe of Landward Dune, accurately depict the jurisdiction of the state under the Shore Protection Act O.C.G.A. 12 -5 -230 et seq. Please feel free to contact me at (912) 617 -6310 if I can be of further assistance. Sincerely, i ft L Ann Thran Permit Coordinator Ecological Services Section ONE CONSERVATION WAY BRUNSWICK, GEORGIA 31520 (912) 264 -7218 FAX: (912) 262 -3143 CoastalGaDNR_org i . /2 1 0 W I fi ( ' ilk I r k I ov 1 - N 8750'03""E. 0) --...„... L -- 0 ' — i <-, 0 F _ L i — -;---- ---- --______ — co TORY ! GRAVEL DRIVE DENCE 1 5 ------- 7 ,-- -- 11 PI ■..._, I ---- ____ . • 0 <'--- ----- _ 1 0 7 ... ■ — 5 ^HP 0 LINK FENCE :C O I 4 , [N ES. PLAT OF LOT ".C' OF A RESUBDIVIS1ON OF 1NLE.T LOTS 21-27, WARD 6, TYBEE ISLAND, CHATHAM COUNTY, GEORGIA STREET ADDRESS: 1805 CHATHAM AVENUE 60 90 zsme firmEaffCr0 - , FOR: KELLY PARKER .. . c. IIC) L3I 2. .. 5' ,2:. - - -- I, c■ R.° """ i. ,4".... 1 /2 RSF p . I N o I F;34-9' I /2" RSF DECK 2 STORY FRAME RESIDENCE ( / '4 „ _........„ .,.... a5 / - ..,',...-..cetaR8F,.., ..._ .._,..,,....., ..... .r l' .-o 1 , I zo / IA 7 0 / A, P. 45- 44 I V' / // N / s' / / / / / / ,,,, / CP / 7' / . / -r* / 1 . , ( „ I / Zs u i, / I /I” REVISED MAY 21, 2009 TO S- W > .." - . w E / w 1 0 co ° EOUIPMENT LIETZ SET 4 I ERROR OF CLOSURE. LINEAR: 1/ 14,700 ANG: 2 "/ANGLE 3. WHITLEY REYNOLDS , , _ BALANCED BY: L. S LAND SURVEYOR °LAT* 1/ INFINITY , 636 STEPHENSON AVENUE . 70 SUITE C , / , ; I I I 30 _ , ,, SAVANNAH, GEORGIA 31405 , , ', SCALE: 1" = 30 ' -- •I'M - "'E - • - ,":,-,_, - ... - . TELEPHONE: 912-352-0464 .. 14 -li DATE: AUGUST 16, 1995 bi ' FAX: 912-352-7787 , , , FILE NO. 95-377 - — - --- -- - — ---,—,4 EVIEW FOR CO COMPLIANCE I i nil Every effort has to identify has been made de �� ° I code violations, f f o ha ee oversight the made de ��� � 'v ' I 1 I o reviewer shall be construed as authority ,,3 2.0' N 87'50 "E ! 216.81' e� 1 -- BE w to violate, cat�cel alter 4 0 -- _�.:�_ --- °------ - - - - - � - - - -' ^ R BF r set aside 5 r` r , - - `-° _. _- , -- - - -- _ .r. ._._._._._._._._._._._.- . -_. -_- - ._._- ._._._._ R._._._._._._._._.-._._._._. . 4 — — — — — — —:�— — — — �++A, �N,rrcE — — — — — — — — review and permit should not be construed any applicable codes or ordinances. The I w as a warranty or u rantee, .�_` - ` +.� µ °� --JD_ �_ ,_ ' BRICK WA j z° nom Reviewed �y g4 i It-,17.. I r _ ! I -? + i GRAVEL DRIVE - - _ _ i i i 1 1 ' -O 1- \ I ! ____ -- - - -- ! � - 1 � I 00 ` = , ,._ , �' 0 --�— T7 "An Approved Se t of Plans AA`" \ DECK / / , 2 STORY FRAME i LOT J ' p �, , RESIDENCE I ' ( r i CJ w W w a a = ° Remain on Job Site at AIl Tia<: \ \ I �\ '�� � � ' '' ' = w r a oa� 4 , 1 -,_� __ . N N o� Lo III _ jj \i' _� I . 0.7' i - ' / 5 CHAIN LINK FENCE /' i' v \ O'��¢ 1 2 RBF '" - - - --- ' _ --- ° - -- -- ' - - - - - - -- - - -- - -- - -- --- ---- -- - - -- i : ' ; ' — — — — - - -- - - - -- -- - - -S 87 S5 - -' - 00 - •- "W ------ =221 83'- - ---- = , d: ------- -- --- - ----- --- -- - -- 61 CD f / / y \` i U AID Nell t �, i d z Q ��NOf!' t11i ells ° t i i \ ` CD I m w Lv comply With The IVr'. Tonal =1 '" a 1 N o 1 0 ° > �dg - n .d 4 be 0 1= _ in LOT "D" i o Q O tit i 0t'gla AMP a d'; aa. . ' 1 '� 0 w Lij O ' i/ i' '1)) � ; ° PRB Q 223 i 5 z' CD Q Q i i ' 1 C!) I J h �1 � /' 7 / I 1 °f ° �Q = i / ' J ,, , — AU Plum i i € ' ii tl'- must i m w LO W � i = mow comply : interst>In�I,PY �- Code__` o Editipti State i --/ � ' w m � of Georgia ,aa�v REVISED MAY 21, 2009 TO SHOW DNR LINES. � i CO O ..- i b H EQUIPMENT: i , % ..-/ � � )) J. WHITLEY LIETZ SET 4 PLAT O F LOT C O F A %" REYNOLDS RESU \ / LAND SURVEYOR ERROR OF CLOSURE B l �/ I S I O I� O F I \LET L ' O 1 j ` - LINEAR: , , O 636 S TE PH ENS ON AVENUE ANG: 2"/ANGLE 14,700 / SUITE C BA LANCED BY: L. S. 21-27 WARD 6 TY B E E I i 0 4>' r- comply with' ' P Y ' / SAVA NNAH GEORGIA 31405 PLAT: 1/ INFINITY , IS 1 % co co Z A16 construction must s co i y w J TELEPHONE: 9 12 - 352 - 0464 Z co The Standard Swimming f _ _ 0 CHATHAV COU \TY, GEORG ° Edition B �vp, FAX 912- 352 — 7787 ° 1 g I � m SCALE: 1 " i �- i � = 30' STREET ADDRESS: 1805 CHATHAM AVENUE \ ! '� DATE: AUGUST 16, 1995 I FILE N0. 95 -377 FOR: KELLY PARKER R i' , 30 0 i ' 30 60 90 DATE 7/1 i' DRAWN BY: T,S, 2/i % ,../ GRAPHIC SCALE —FEET i i SALES: B.C. --- PROJECT: / PARKER SITE PLAN i ; i i SCALE: 1/32" = 1' SHEET NUMBER: OF 4 I - a � a N La i (3 I � IREVIE��C CODE 4 , All um lnelletlona muet •x Ever ��, COMPLIANCE PLIA : " !ectrtcat installations must y e#'fc�rt h6�s NC E' .� °,ply with The National Electric comply pt with bing 7The ln terna #inn :�l �lurnhln �� wF n n on J©b Set of Plans ust code vioiatio,� been r ado to identit cde '� / � Jm`Z° o �� ° az ono reviewers ,aii ° no ov b the Z .. .M b Uitiorl snd St ate Code Ed 'itton and tae � Z�Z ° ~o 6* Remain on Jab Site at AU Tirpes rs , h nstrue of Ge orgia Amanda, &, c of Ge or is Amendments ozo z ,„_ to vio e n r d s ca ,r:seTa„ d as aar El w =W a�N= , � � I r or seta =z�� & Z a ny sppi s )t e side = z ZQ °oa x review and or or.inancesx The 1 c " "1`i3? <V , � � a ye construed 2.0' a��o�z =�� 1 g ranie y or , u _ La° 1.0 , �, A lt const��, Ai :; ,t =i mply wit , !Reviewed y- .z� , 0 -; 152 QD The Stand: _ :,; =3 °s:l,r " rr�€�o! Cod ® r {�, +' b -� mate 2 1 0 W W _ a a a ° Z 6 7 a C-cPIL I WWaUw o Edltlon V) X ''S)--4 l� / — / S) l /l /p x x x - x - x X x PROPERTY LINE _ _ _ — — — — — — — — "*--/ x- x -x.. x —x —x— .. .._ — — — — — x — x = x __ x — x — x — x — — x x — x — x — x — x — x — x— CD 0 I 3 ft. __ _ ___ -- ---------- - - - - -- ODI1jC� 4� I I �p �7 O Q Q O CC 106,./4 I— _1 W I �, I BEN H 1 0 '1 PINE• I I X = O I W W • I S A -18 INCHES A OVE -e O Q z k sr k P uuErro• puuETTO GRADE. 4JETS/ (1) / P / 0 '.< = Q I 100 WATT LIGHT &) / • / • Z 0 (n I I CHANNEL DRAI < P wl I P / °� \ W W z 1 — P — J = W Aq'N'''' W O~ J / ® 5 ft. de pth / PROPOSE POOL SPECIFICATIONS m I POOL wl 1 STOF 0 o I (18 in. above POOL SIZE: 16' 3" x 34' 0" f I I grade) POOL AREA: 533 SQ. FT. °' POOL PERIMETER: 98 LINEAR FT. c?„) , , ERAVE WALk IN DECK AREA: BY OTHERS STEPS SPA AREA: 42 SQ. FT. 6* SPA PERIMETER: 26 LINEAR FT. R E S I E ` / � I I TOTAL PARCEL: 33,445 SQ. FT. 3 ft. > IMPERVIOUS: 3,922 SQ. FT. ! !`. \) depth ---) Ac • Z�� (( ` l O I� M Y Z_ it t0 / / /1 'c) / / / DATE : 2/17/1c DEC / 2 STORY E R A V E DRAWN BY: T.S. SALES: B.C. / / / / / / R ES I D ICE PROJECT: / / / PARKER / / POOL LAYOUT SCALE: SHEET NUMBER: // '� 1/8 = 1 ' / OF / U' 1 4 -).• L O O 7) °- S w ce H g LL _i..L.. i= EQUIPMENT NOTES: zoc7o':°Zz- * EQUIPMENT PAD IS BY "YRP". * LAYOUT SHOWN IS FOR un.ux,zz- nm rr p ILLUSTRATION PURPOSES ONLY. FINAL L L ' ,,, w ; 0: • LAYOUT IS TO BE DETERMINED ON-SITE. I 2-0E, _ . __ 0 < zzt u z=x<z / v) LLJ -62 ZUCCI,.. •ZL,..I 1 o f< L t ow o w cn EC ■ I ___I CD i 4 C 4■ 4 : !!l 1 H.P. JET 1 /2 I-11 mo Li (r2---- Pr ... _. I I I 1 lij n — > H.P.CLEANER PUMP CIRCULATION PUMP PUMP I— 1— Li L j LJ ° Lii 0_ LJ = 0 O 7, F- z 0 < _1 Z U 0 (/) POOL/SPA SHAPE EQUIPMENT LAYOUT < --...., CL — / 0 0 Z LJ LC LJ SCALE: 1 /8" = 1' SCALE: 1 /4" = 1' cn o — El— co oo LJ C.) ‘--- >- LLJ L CL I— CID Cn 0 ›- L_ I— (J) Cf) 0 CC 0 POOL COPING / 6" 1 ', zi Iffilingiiiii, ',' Lo 4 -.....1 CD CO SPA 1=1111.= 4 .° =II j7 it \ 6 N to SPILLWAY POOL CCPM AND NY i TiAbrAl WA " • I — CONCRETE POOL WALL, fr MIN. B DIVS \ "'" D CO h 7 COFING DECK Y ER : . z -- _ff ,r, "1) e3 ,J, r i, -...—.. , - I= 1. ALL REINFORCING BARS ASIA A 817 GRADE 60 co co NM ..,:f■-■—.11•••■•■ , „ 6"X6" FROST . •.4 = r GRADE V :Y ". ' ,. e EDURA STONE MIN 3 ■ GRADE v) PROOF 11LE . — 1 _..1 2. WALLS & FLOOR W/ #3 REBAR 12' 0.0./B.W. 11ED 68% ILI : 1=1 400+/ATT / IN 3 I ZEDUKA - 1 :.:, ■Nriffliti .- — I I I= 3. T liAlp 81 TOP OF .1 > MN. le • - ... •Tallf N..' r POP. FLOM , ; •••••■ 4. 4,000 PSI CON. Eth= ......• . . .. . ..• _ , — •• • • I— -- -. -NH 1=il DATE : 2/17/1C ' 11 . .. . FLOOR ....... W •• ' -= • 1 II MIN. 6" RADIUS . . - I DRAWN BY: T. S. • - ' , --' r POOL FLOOR • : ' l I SALES: B.C. ...-• ,....• '`--- • 4 . . ',''' . '1 11 . • • • —I I 17 PROJECT: 111111=11 1thI i, 111=111=111—III= PARKER SHEET NUMBER: POOL CROSS SECTION SCALE: 3/16" = 1' CD CONC. WALL DETAIL (.1) \,.... OF 4 SCALE: 1 /2" = 1' W efi Z o O N a S w 32" ct a u z v 0r- a o inzdaoa,a MEIN • _ : _ I r y 1' 2 s W w Z . ►�Ir' � _I : (2'1,-1z__, O �o - ∎ ril_ ) COPING BY LJ ! 3 z 11W11111 . • : ° '' � � I I STEEL OTHERS = z ° m _ o w z �I - I I , REINFORCMENT I— o ? z� NO � � �� � 1 �i,_' /� it = zzQQZ= 0 a¢> 32" CHANNEL .�1�.��I��..�...����t /�����/ _ a¢ s ¢ w w¢ TOP VIEW DRAIN GRATE 111��1��1NNI��� ^ 6" THICK 161111111116111111111111.1111111611111111111110111111661 °' 7 g a o° z o 0'" _ - 1 — — I'• CONCRETE FLOOR ! J ' III= 0 z o � � � • III. �/� SEE DETAIL 4/3 0 w "''-' a a now o = z �_ �;_ FOR POOL WALL r w a o w 3 0 �, � t: F a �Ialib / PLUMBING TO CIRCULATION � . I SPECIFICATIONS wN u 7 -7: . a. —L � '" PUMP (SEE PLUMBING PLAN I — � �� � � FOR PIPE S _ ` — i 18" X 18" X 24" 17 • ' 4. • ° a : . ° • I -I ° � . 4 : P 7 0 / GRAVEL SUMP # 57 . I. • • • • . a : I =III ° III- iv ��� `- +!° /\ GRANITE STONE a d'O d• J _�_•_�•_�� - J a °. • • /� MANUFACTURERS NOTES: ...',.:° III — I 0 Q • i= .==t =;•` •MANFACTURED FROM UV RESISTANT ' a ° ' I — J Id ED Z ~ Lil :�_������� SUPER STRONG ABS MATERIAL. ° ° ° a • q, . < ' l a III —I W U •UNBLOCKABLE,ANTI- ENTRAPMENT • • a . c . • . ° ' _ FILL 95% PAC / � 4 / SINGLE SUCTION OUTLET NO SVRS a / I —III Q Z Q REQUIRED E ER AP _ ". • . III c ' L i 5 • FLOW RATE 316 GPM FLOOR, 208 GPM • I —I 1 - 1 — I I I - 1 I I I I I — I I- o W > cc WALL) (ESTIMATED: PENDING IAPMO 6" POOL I ( —) I I I I I III III —III —I III III I— W < 0 Lu •MEETS OR EXCEEDS ASME /ANSI FLOOR — IY 0 A112.19.8 -2007 STANDARD. •USPC LISTED Li _ Z CL H _ Q Q 0 CD Q = J MAIN DRAIN DETAILS WALK —IN STEP(S) DETAILS z m - SCALE: 1 /2" = 1' S CALE: 1 /2" = 1' — try m=oLI LJ H m w v i2 I � z0 27" CONCRETE COVER I— _ LIGHT JUNCTION BOX Q MIN. 48" > m ANY EXISTING DECK AND COPING W • BY OTHERS ° 11111\ I • • .. 1111 ' 1 z C V Mir/ .. 3/4" POWER SUPPLY ..1.1 WATERLINE t ' N') ✓I'IO ✓/ �I'�I'�I /I �I' CONDUIT ° . A — ` o � " M �� j�� V$j �` ; ,� y �.� SEALING ° + "` -ill �i�i�� /��Yi i PLASTER � C ' V m rn `�``'``'``'``'`{ 1" CONDUIT t I z ` ��`';���� \ SKIMMER LID AMD SKIMMER WEIR ' � } ��� i , �`�`�`�; COLLAR 7" M I TILE INTERIOR ' ��+ I ° ....W Wllr 1 L E DATE : 2/17/1C y Al Or -A** .... . . POOL l � � 1 -III . I z _ LIGHT 1E=1 `� `�`�` j.r : � WATERLINE DRAWN BY: T. S. ��j�j�j� I a # 8- GROUND CLAMP WITH 1 I NICHE N — I .. :• WIRE TO LIGHT FIXTURE III SALES: B. C. I . ENCASE WITH SEALANT I I — I • • ' ' . ' . . '` • EXTENDED WALL � POOL SUCTION LINE TO FILTER 4111111111:•11111111111i ; z" EQUALIZER LINE PROJECT: IN LIGHT AREA LIGHT - III III= III =L — I ' _ PARKER FIXTURE ; I I I —III- I I I III : 6" POOL WALL POOL LIGHT (TYPICAL) SKIMMER DETAIL (TYPICAL) III — I III SHEET NUMBER: .1 11E — .. SCALE: 1 /2" = ' ® SCALE: 1 /2" = 1' ® OF 4 L 0Waj v, . 0 CA z 0 D 0 (..r) > L.LI L.I I-- 0 1/2" RBF ct, 1 1 N tt, I e... , ,..., w ..,-- 1 , v I 0,3, ".. LOT "B" i I --: ..t• I trl N t I '42 ; rn ( le I e P 0 i A 0.5 i < k":" 2 N 8750'08"E 216.81' .. _1/2"„ RBF te . _ , I .3 5' CHAIN LINK FENCE 1 1/2 RBF 3.8' 1 BRICK WALL 1 C) 1 ; 1 r- • I PP- ZN 1 GRAVEL DRIVE I -"' sib 0 IrSTOr I p ., 1 ___....-----------...,_ CS V ! RESIDENCE -4 " L.11 \ ...- D \ i / 11/2" RBF 7 , LO "C'' ..... . I z \ .c) ' t Li • DECK 2 STORY FRAME ( ,,.. .. 1 •-.I >_..... \ RESIDENCE , x .. I 1 • -' ..' I is,) \ ••. ../ s, ... , ,..... ,-----' 4o. /2 ■ 01 4 05 „, ....---- 1 < 6* N. ----. o.7. I 1 ---,_____ , ----- III 11 4 IF' ';" /-1.7. — - 8 . - CHAIN LINK FENCE 7 ,.. - .• <L. / 1 : 3 ,-3 \ \ , 4- BF __ _ 30 ‘ 1 _ _ _L— ______ S 8 ____ 755'00"W 221.83' I 1 I = 0 / ,... ...s. 1 1 I / I I /-*/ \ I ^ t 0 *;...., i .....• \ 8 1 '-. 0 \ . LOT 'D" I I z le , . . 6 z ,, 5 t....1 PRB Q 223 I (A r \ / 0 V % 7 , 7 c, ,/, ,a0 .. 1 3 0) PCP iK.,.. , / I I (A - i I, ..„/ / 1 / i ( / co , ..... . 1 ir , 'NI -.4 //' ,,,,-/ / / / / 1, 0 S /. / z' [ t ' a ./ 4 Li 0 . E q R ii z : r-- z tri / V-1 ■ ',:. :.';'1 CO CO r-, .."" REVISED MAY 21, 2009 TO SHOW DNR LINES. / : z > / TX .. / .../ 3 LL.I 7 r V) CV Z ,9 ) / i 9 1 Cn b / P AT 0 LOT C OF A a. / Lki . 1 Z 1 //`" EQUIPMENT: . 14/ .4 LIETZ SET 4 R=SLBDIVISIO\ 0= INL- LOTS I dr ri ERROR OF CLOSURE: 21 —27 WARD 6 — YB 7 E ISLAND u 1, il LINEAR: 1/ 14,700 I / 1 frEPs%st/H '1 ANG: 27ANGLE 1 J. WHITLEY REYNOLDS , BALANCED BY: L. S. C —AT—AM COL NTY G= LAND SURVEYOR PLAT: 1/ INFINITY 636 STEPHENSON AVENUE 0 30 STREET ADDRESS: 1805 CHATHAM AVENUE SUITE C I i I 30 0 30 60 90 SAVANNAH, GEORGIA 31405 SCALE 1 = 30' • • • II NI •111•11111111111•11111 TELEPHONE: 912-352 —0464 . DATE: AUGUST 16, 1995 •IIIII•1IIMIIIIIIIIIIIIIIIIIIIIII IMIIIIIIIIIIIIIIIIIIIII FOR: KELLY PARKER FAX: 912-352-7787 FILE NO. 95-377 GRAPHIC SCALE — FEET PRO,L- P A\ SCA S- \ MB I- . . 15 / / CD ----/ ....-/ / / 2 _ o-t--- u / 1/2" RBF Z - N 1 Li I U' -.' m al tx a co N O� O LOT "B" I N N pe ‘7.. I m 0% i x 1.3' N 8750'08't 216 x 2.0' _ �2" RBF LaJ �' �. x - X - X X ! X 5' CHAIN LINK FENCE 1 s 1 /2" RBF 3.8' N / e BRICK MI O I • 1 111111111.11X MI II o iv O 1 1 STORY I GRAVEL DRIVE x 1 �a CO Cyi RESIDENCE E W 4. i ll /2" RBF x D . 4‹.. limed 1 LOT w DECK 2 STORY FRAME ' v RESIDENCE " 01 Q / i 4.0' 4 : P ??„, C5 X0 Q tll.� � .' ,Qt- 0 7 = 1a' _ . 5' CHAIN LINK FENCE _ M / \ x , n , � — x X x �L�.� 6. �. �� �..� �L... .. CMF X \ 1 2" RBF �. "' r. / — S 8755 221.83 U / t / 1 `° / r21 N O I o , CO M 0 LOT "D" I °' + • PRB Q 223 0' �OO OO / u) 4 / / I co 4 ., / 1 .1, / � g0 / c. / s c. c,i / / / / / / / / / / A / A_ o / A O / /yQ 1� /c -co „0 MI ■ / W h 1 / REVISED MAY 21, 2009 TO SHOW DNR LINES. / w / LU Mi / CO LI ° o 1 // PLAT OF LOT » C ” OF A r Z � Tr EQUIPMENT: f - �, r LI ME SET 4 RESUBDIVISION OF INLET LOTS z ' ERROR OF CLOSURE: 21-27, YYAR D 6, TYB EE ISLAND I. �O 9 § , LINEAR: 1/ 14,700 '� ANG: 2" /ANGLE CHATHAM J. WHITLEY REYNOLDS BALANCED BY: L. S. HATHAM COUNTY GEORGIA LAND SURVEYOR `' V PLAT: 1 / INFINITY 636 STEPHENSON AVENUE .i �. 0 3G STREL I ADDRESS: 1805 CHATHAM AVENUE SUITE C SAVANNAH, GEORGIA 31405 �j I i 30 0 30 60 90 SCALE: 1" = 30' FOR: KELLY PARKER TET.FPHONE: 912- 352 -0464 DATE: AUGUST 16, 1995 FAX: 912 -352 -7787 GRAPHIC SCALE; - FEET FILE NO. 95 -377