Loading...
HomeMy Public PortalAboutMILLER AV_14 u , CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 03-28-2013 PERMIT#: 130193 WORK DESCRIPTION ELEVATOR LIFT SYSTEM WORK LOCATION 14 MILLER AVE OWNER NAME ROBERT HERRING ADDRESS 14 MILLER AVE CITY,ST,ZIP TYBEE ISLAND GA 31328 PHONE NUMBER CONTRACTOR NAME TYBEE STAN THE HANDYMAN ADDRESS PO BOX 807 CITY STATE ZIP TYBEE ISLAND GA 31328 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 65.00 I PROPERTY IDENTIFICATION# PIN#4-0003-14-014 PROJECT VALUATION $1,000.00 TOTAL BALANCE DUE: $ 65.00 It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire,soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: ,/,� V(: Art P.0.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328 (912)786-4573-FAX(912)786-9539 www.cityoftybee.org j �Y9P1 7. \ 1� g� ti �; City'of Tybee Island • Planning & Zonrng Dept. 7�:a i '`j Inspection Report ga� ‘,, i 403 Butler Ave. • P.O. Box 2749 • Tybee Island GA 31328 Y • a =® INTFRNArioNAi- Phone 912.472.5032 • Fax 912.786.9539 CODE COUNCIL MEMBER Permit No. !', ' J/93 Date Requested JiA6,2,03 I Owner's Name ka&PAT 146 PI 146 Date Needed 6 2?l o; 3113 Gen. Contractor. AA ) 5601AG 2 Subcontractor Contact Information �-r4 N1 3o g " / ( 5 7 Project Address 14 /0 ittc,de )4 V f� Scope of Work LC VAro,p L r F r Y5-rt M Inspector '1/`a Date of Inspection t1 /z� i Inspection r°°l- ""°' -:5-/4/-` ' ..si / Pass El Fail 0 Fee - AI) -A-7f, 3-UAL.'/ �6, i :�� r .J h--4 3 - 5,r7 ''' j '0 / J;7/ C -rte / Inspection Pass ❑ Fail ❑ Fee Inspection Pass 0 Fail 0 Fee Inspection Pass 0 Fail 0 Fee Elevator4ift Home Office:365 Red Cedar Street,Suite 104,Bluffton,SC 29910 • 843-785-7101 Syst ems n 330 Robert Smalls Parkway,Suite 24, Beaufort,SC 29906 • 87400 Abercorn Street,Suite 705,Savannah,GA 31406 • March 15,2013 Robert Herring PO Box 2087 Tybee, GA 31328 ACC: 912-786-0372 RE: 14 Miller Ave. Dear Mr. Herring; Elevator Lift Systems,Inc. is pleased to quote your vertical platform transportation needs as follows: 1 ADA,ASME Code Compliant Platform Lift $18,300.00 108"Travel Solid Platform 550 lb capacity Carriage Gate Adj.RT hand exit Keyed Pushbutton on Upper Safety Pan Landing(incl.w/gate) Upper Landing Gate Lower Landing Interlock Keyed Pushbutton on Lower Landing GA Inspection $ 400.00 Installed per State and local codes TOTAL $18,700.00 Deposit $ 10,000.00 Delivery $ 7,000.00 Completion $ 1,700.00 Lead Time 14-21 Days factory 7-12 Days shipping 1-2 Days install i5 J ff McCandless Date Owner Date See our website WWW.ELEVATORLIFT.COM Elevator Lift Systems,Inc. 365,Red Cedar St. Ste 104 Date Invoice# Bluffton, SC 29910 3/15/2013 16189 Bill To pit • Ship To Robert Herring IIPPrn 14 Miller Ave. PO Box 2087 Tybee,GA Tybee,GA 31328 Terms Project Description Amount 108"travel platform lift $18,700 10,000.00 Deposit $10,000 Delivery $ 7,000 Completion...$ 1,700 Total $10,000.00 Page 1 of 1 Subj: 14 Miller Ave. Date: 3/18/2013 4:15:18 P.M. Eastern Daylight Time From: ericaCcs7elevatorlift.com To: tybisland@aol.com Hi Stan, We have placed our order for the handicap lift equipment for 14 Miller. Prior to the istallations of the equipment there are a couple things that must me done. 1. 65"x 65" cement slab, 4" thick; to be located 2" below the garage slab elevation. 2. A 3' x 6'8" door right hand out swing. Installed at garage level. 3. Upper landing removed and supported. 4. Safety wall built under upper landing gate. Lets meet on site so I can explain. Thanks, Jeff McCandless Monday, March 25, 2013 AOL: Tybisland 1 1 ■ SPECIFICATIONS: IL ❑Accepted as Shown — 40" x 54" LIFT PLATFORM — 54" x 54" FOOTPRINT ❑ Revise and Resubmit — 142" TOWER HEIGHT — 0" — 120" LIFT RANGE ❑Accepted as Modified — MAXIMUM LOAD 550 lbs. Date: —- SCREW/UTUWORM LIFT SPEED GEAR DRIVE — MOTOR: 1/2 HP. 110V AC, Per: — POWER SUPPLY: 110V/1PH/60HZ C/W 15A FUSED DISCON. — NON—LOAD BEARING BACKUP SAFETY NUT ON LIFT SHAFT— SAFETY HANDRAIL ON CARRIAGE — ZERO—LOAD START IN BOTTOM POSITION — SOLID PLATFORM NOTES:— Dimensions are in inches— Designed and built to meet ANSI—A17.1 Safety Code 58 12 1/4-2 t r — •/- 38 1/2 44 3/4 56 R.O. FOR ;'/' z 11 1/4 A 36" DOOR n 40 J L..1.-J Z Q At /y ill It i PITLINE o • � ��:>— .113/4 5 1/4 I, a 54 v z � 54 -00° v;;' N W 3 T 38 1/2--ter -�— o TRUS-T-LIFT DIMENSIONS PLAN VIEW SECTION 16 3/4 R•O' 2 3/4 m a TOTAL No. OF TRAVEL 120 INCHES LANDINGS 2 LOCATION ENCLOSED RESIDENTIAL TRUS<T>LIFT TRUE LIFT ADJACENT ACCESS SAMPLE DRAWING OWN. BY: TRUS-T-LIFT ELEVATOR ARCHITECT B.H. INSTALLATION DETAILS CHECKED BY: GENERAL CONTRACTOR SCALE: N.T.S. DATE: 25/02/04 1D20URLEDNo. i/2 REV • .A RESIDENTIAL DOOR ROUGH OPENING DOOR INTERLOCK Pil • ////%//% //%%/ %/ //% ///%-ow- Selp NOTCH O TOP ------------------------ OF DOOR u-: JAMB ® 45' N co TO ELIMINATE o w in SHEAR HAZARD 1.-- o 120 N W O TOTAL TRAVEL ...{ ■ E I. XCLUDING PIT /%%// ////7.//%//%//%//%///% %////%///i SECTION A-A TOTAL No. OF .- TRAVEL 120 INCHES LANDINGS 2 LOCATION ENCLOSED RESIDENTIAL TRUS<T>LIFT TRUE LII FT ADJACENT ACCESS SAMPLE DRAWING ARCHITECT DWN. BY: TRUS-T-LIFT ELEVATOR B.H. CHECKED BY: INSTALLATION DETAILS GENERAL CONTRACTOR SCALE: DATE: DRAWING No. REV N.T.S. 25/02/04 12OURLEDDNAP 2/2 -0/93 /SEE City of Tybee Island, Georgia %' \, 912-472-5033 or 912-472-5031 Fax 912-786-9539 1 APPLICATION FOR BUILDING PERMIT Property Address: i 4 A :11 ex' AV QJ. /7/- 0003-/71-47/,1 Name Mailing Address Telephone Home: q�/V) 86 " - '7� 4--j Owner *,L05L--\--1-)e- e7211 0 A PY,, ') Cell: g n g ii 4 s`9 Architect or tCe-r,().0-44-> „--, Engineer f I Q o d.sA le $7J sPRI `_'�,,,I to ea-- 64-Gun � 4a w.a..r, Office: Cont+� e- 5 �D g -7 lv 3, cI Cell: El V o�l-o r- (,.a`�1- S l�S rv�S `_ i-ay, r, .s (ab (Check all that apply) Single Family ❑ Discovery/Tearout ❑ Demolition of Structure ❑ Duplex ❑ Footprint Changes— ❑ Other ❑ Multi-Family units new square feet ❑ Commercial units heated/cooled Details of Project: 1 r> S1-0.V. : si r- 0 (3 a +Go 06' k C c 0 .% ?41 rr i'l 7wy+i7 / J?Z 4/F% 5`�f►.r¢Di=L,A-• Estimated Cost of Construction: $, # wmzsr% (materials + labor+ profit/overhead) If applicable, attach a copy of the certified elevation certificate and/or survey of the property. Depending upon the scope of the work, two sets of construction drawings and/or a site plan may be required. Year Built: Listed on National Historic Register or located within a National Historic District? Y / N *Buildings older than 50 years may be eligible to be listed on the State/National Register. With this designation,you may be eligible to take advantage of various tax incentive programs while preserving the heritage of Tybee Island. *Also see the Tybee Island Land Development Code Article 14: Historic Preservation During construction: On-site restroom facilities will be provided through . Construction debris will be disposed by by means of . I understand that I must comply with zoning,flood damage control, building, fire, shore protection and wetland ordinances, FEMA regulations and all applicable codes and regulations. I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected as required by Article 16, Stormwater Management. I accept responsibility for any corrective action that may be necessary to restore drainage impaired by this permitted construction. rc 5 ct,12n ∎a` • Date:c) .2 4 - ,'' Signature of Applic^ . FEES Printed Name ,A/,,.0 z),, ,,s u Permit Inspections Note: A permit normally takes 7 to 10 days to process Cap Cost Rec Water Tap Approvals: au toe Date Sewer Stub Planning &Zoning Manager 11 3 -2,e-13 Eng. Fees , Building Official 5/2-I0 r Aid to Const. Water/Sewer Storm/Drainage City Manager TOTAL LEAD-BASED PAINT RRP RULES Ordinary renovation and maintenance activities can create dust that contains lead. Contractors who perform renovation, repairs, and painting jobs in pre-1978 housing and child-occupied facilities must, before beginning work, provide owners, tenants, and child-care facilities with a copy of EPA's lead hazard information pamphlet Renovate Right: Important Lead Hazard information for Families, Child Care Providers, and Schools. Contractors must document compliance with this requirement. After April 22, 2010, federal law will require you to be certified and to use lead-safe work practices. Georgia Environmental Protection Division Lead-Based Paint and Asbestos Program (404) 363-7026. Projects must be done by a Certified Lead Renovation Firm AND a Certified Renovator When disturbing lead-based painted or coated surfaces or components more than 6 ft2 per interior room or 20 ft2 of exterior surfaces AND all window replacements and partial demolitions of any size. * * * * * * * * * * * * * * * * * * * * * Asbestos/Environmental Notification to Georgia EPD for Projects Involving Demolition, Wrecking, or Renovation The undersigned hereby acknowledges that the issuance of this permit does not in any way grant permission to the owner, owner's representative, or permit holder to proceed with demolition, wrecking, or renovation of a structure prior to the filing of any required ten (10) day "Project Notification for Asbestos Renovation Encapsulation or Demolition" form in accordance with the Georgia Asbestos Rules. The Georgia Environmental Protection Division administers the rules. In most cases, the rules require both the owner and the involved contractors to assure the portion of the building involved in the project is thoroughly inspected by an Accredited Asbestos Inspector for materials that contain asbestos; and the removal of the asbestos before renovation, wrecking, or demolition begins almost without exemption. Georgia EPD requires a completed demolition notification from be submitted 10 workings days in advance even if no asbestos is present in the building. Further guidance for regulatory compliance and contact telephone numbers are provided by the brochures entitled Asbestos & Renovation and Asbestos and Demolition. Other environmental issues such as asbestos removal techniques, lead abatement, ground contamination, or unusual site conditions may have EPD regulations that could affect the project. * * * * * * * * * * ** * * ** * * * * * BMPs While BMP deficiencies are not necessarily the fault of the owner or his agent, BMPs are their responsibility. Two areas of deficiencies are in the most basic and common BMPs; Co — Construction Exit and Sd1 — Sediment Barrier. Correct installation information can be found in the Field Manual for Erosion and Sediment Control in Georgia, Fourth Edition 2002, Georgia Soil and Water Conservation Commission; http://www.gaswcc.org/docsifield_manual_4ed.pdf. Problems with the Co is not limited to the installation, but to material. The stone will be a representation of 1.5"-3.5" stone or larger. Type A sediment barriers have been installed where Type C is required and shown on the permit drawings. Where two rows are called for they will be installed with a separation that allows for the first one to fail (fall over) without impacting the second one. The complete assembly and installation must be compliant; steel or wood posts, post spacing, Type C or A. Signature for receipt of Lead Paint, Asbestos, and BMP notices. Date Printed Name