HomeMy Public PortalAboutVENETIAN_1202 n
Y
F-d , JJJ
A/
4mmayaA
CITY OF TYBEE ISLAND
BUILDING PERMIT
DATE ISSUED: 04-11-2013 PERMIT#: 130231
WORK DESCRIPTION 3 GLASS DOORS/R&R ROTTED SDG
WORK LOCATION 1202 VENETIAN
OWNER NAME ROBERT EVERETTE
ADDRESS 13224 OLD COFFEE BLUFF RD
CITY,ST,ZIP SAVANNAH GA 31419
PHONE NUMBER
CONTRACTOR NAME TONY KONCUL CONSTRUCTION INC
ADDRESS 13318 OLD COFFEE BLUFF RD
CITY STATE ZIP SAVANNAH GA 31419
FLOOD ZONE
BUILDING VALUATION
SQUARE FOOTAGE
OCCUPANCY TYPE P
TOTAL FEES CHARGED $ 109.00
PROPERTY IDENTIFICATION# PIN#4-0011-01-001
PROJECT VALUATION $8,000.00
TOTAL BALANCE DUE: $109.00
It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire,soil
and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all
environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be
approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction
covered by this permit.
This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work
will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless
work has begun within six months of the date of issuance.
Signature of Building Inspector or Authorized Agent: fA/?//d/ Q. /
/
P.0.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328
(912)786-4573-FAX(912)786-9539
www.cityoftybee.org
I
.'
441 '' ',. ' City of Tybee Island • Community Development Dept. =\
,-4 Inspection Report ��s\
403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328
mamma
Phone 912.472-5032 • Fax 912.786.9539 CODECOUN IL
��,��`" CODE COUNCIL
MEMBER
Permit No. 1.3 --7..,:
I Date Requested f/5 �
Owner's Name Date Needed 4 //
Gen. Contractor x>?41y A- ' '/ Subcontractor
Contact Information 54i-z,-44.10/5= t.6. . •
Project Address 2Z. }/C d -I, J
/
Scope of Work ,`.i5 /7)C)i:, !4-=J fea-. ' 5rc.l
Inspector Date of Inspection
Inspection , 6f , ;/ / " ' ., Pass Fail 0 Fee
Inspection Pass 0 Fail Fee
Inspection Pass I—I Fail r1 Fee
1____I
Inspection _ Pass -1 Fail Fee
IIII i!
05/22/2013 09:48 COASTAL SASH & DOOR 3 91=7869539 NO.092 D01
COASTAL SASH AND DOOR
Fax Transmittal Form
TO "PCL. FROM
Name: ettoriv-/
Organization Name/Dept
CC: Phone;9I2-352.3930
Phone number: Fax:912-352-7966
Fax numbed
yrgent Date sent n I'a.- /3
For Review Time sent:
Number or pages including cover page;
Please Comment
OCioe, I m �`-knOLA) I f c,,o - O'er h9
00*Onal n 44Y\l` OsiN‘ 4tOWIL-Odi
CA
Q&
Nap5 5rog
8422 FERGUSON AVE.
SAVANNAH,GA 31406
Phone: 912-352-3930
Tax:912-352-7966
05/22/2013 09:48 COASTAL SASH & DOOR 4 9P7869539
NO.092 D02
DISTRIBUTORS OF:
VIN+f
W.ntlbws ...d Dnnrs
Madeforyou'
"IL COASTAL
SASH AND DOOR, INC.
May 22,2013
Ray
City Of Tybee Zoning&Planning Dept.
Savannah GA
To Whom It May Concern:
Please be advised that three doors purchased from Coastal Sash and Door Company for
the Robert Everett Res. @1202 Venetian Drive are all tempered low E 366 Argon Gas
filled glass doors with clad exterior/wood interior.
All doors have been tested and meet the structural design pressure test with a+52.5/-
60ps£
Please do not hesitate to let us know if you have any questions or need any additional
information.
Sincerely,
lektak &€00 el/t/
Gloria.Braddock
Coastal Sash and Door, Inc.
8422 Ferguson Avenue 206 6 Sylvan Drive 3653 Regent Boulevard, Ste.205 980185 Gateway Boulevard
Savannah,GA 31406 S1,SImmons,GA 31522 Jacksonville, FL 32224 Amelia Island. FL 32034
(912)352-3930 (912)634-1414 (904) 841-0346 (904)261-0488
05/22!2013 09:48 COASTAL SASH & DOOR 4 9P7S69539 N0.092 D03
Materials Technology Stork Twin City Testing Corporation
Summary of Test Results
Product Manufacturer: Marvin Windows&Doors +r
Product Type: Aluminum Clad Woo Sliding Glass Door
Product Series/Model: Clad Ultimate Sliding French Door(CUSFD)
12080 OXXO
Primary Product Designator:
AAMA/WDMA/CSA SD-LC3S 3632 x 2426*( 143x 96*)
101/I.S.2/A440-05
Class LC-PC35-Size Tested 3632 x 2426*
AAMAJWDIVIAICSA (143 x 96*)—Type SD
101/I.S.2/A440-0S
Secondary Designator: Canadian Air lnfiltration/Exfiltration
Level A3
Negative Design Pressure 1920 Pa(40 dp)
Test Completion Date: 09/16/10
Air Infiltration: 0.11 cfm/ft2
Water Resistance Test Pressure: 6.0 psf
Uniform Load Deflection Test Pressure: X40
Uniform Loy dhig sKg IMY. f 4,52,5/-60 psf
Forced Entry
Reference must be made to Report No. TCT004455P-0162,dated 10/15/10 for complete test
specimen description and detailed test results.
Mr+1)(CAA —P 1\3 -
(on a, lardef door)
4w/0a,
8C)ObC
05122!2013 09:48 COASTAL SASH & DOOR -� 9P7869539
NO.092 D04
siromie
Stork Twin City Testing Corporation
Mat�riats 7®chnoia�v .,_
PROJECT NUMBER: TCTO04455SP-0i62 PAGE: 1 OF 7
EAR-CONTROLLED DATA DATE: 10/15/10
STORK TWIN CITY TESTING
115 South 8416 Ave
Wausau,WI 54401
IN-PLANT TESTING OF A
CLAD ULTIMATE SLILIING FRENCH DOOR(CUSFD)
12000 OXXO
MANUFACTURED BY
MARVIN WINDOWS&DOORS
Prepared for;
MARVIN WINDOWS&DOOR$
Attn:Mr.Skip Bornemun
Highway 11 West,P.O.Box 100
Watoad,MN 56763
Test Dates: 09/16/10
expiration Date: 09/16/14
Prepared By: Reviewed.By:
'' 1r
Gary Norenberg John,Bordagaray
Technician Manager of Fenestration Testing
Product Testing Department Product Testing Department
Telephone: (715) 848-3935 Telephone:(715)848-3935
The test results contained in this report pertain only to the specimens tested and not
necessarily to all similar products,
This document contains technical data whose export and re-export/re-transfer is subject to control
by the U.S. Department of Commerce under the export Administration Act and the Export
Administration Regulations,
The Department of Commerce's prior written approval is required for the export re-export/re-
transfer of such technical information to any foreign person, foreign entity or foreign organization
whether in the United States or abroad.
ill WIN*mY.1114toMarbin Ibis MUM aredtrivatTnunmeantl l,iormoalovo mato spotifiraoiorai dimislatetrytheciirniameeclwavanyraprtvrala7YFlial*Tnrnnihiall0.+Amram,
edit,ma/6,004d or■i ly ad r•any patiwlAT rant +e a ttne.Roc email is h is aaralliarairo pMreny or oarsiiaa wet moy not to oral for ndtrorlildM Pu pnFes,'rhis repon shall we be
rgrradaaal etgln in be!,Hndaxn wrlmn appmval orltdc lobnrtaay rite reearelin°ebbe,flr`litiaus nr frawlalaa woman*te WAIN on Ada bo r=maybe tmnialen as a taloayundo(
wore!sews inch IbeFaders!6sis1iI1eI IS,Cb3IAer47
Stara Tod!)City Teaung is an tiperaiiny link°ISO)*Materinle Tochx tndy A.V.,nnniorclam,TO Nathanap0.,which to a ti embCT of the Sbesit pmop
05/22/2013 09:48 COASTAL SASH & DOOR 3 9P7869539 NO.092 D05
COASTAL SASH&DOOR INC. Invoice
8422 FERGUSON AVE
SAVANNAH, QA 31406
(912)362.3930 GATE I INVOICE ri
4/17/2013 13000-224
Al 0
BILI_ TO; SHIP TO
- q Y . •
1202 VENETIAN DR.
SAVANNAI1.GA 31328
F.O. NUIVIFiER I TEAMS REP SKIP i VIA F.O.B- PROJECT j
Gra 4117/2013 Our Truck loh Site
UI.IAN71I V ( ITEM CODE DESCRIPTION PRICE EACH AMOUNT
7. 1 /2Qf7 00 __
L ,
1 , ,„0 fi..'10p1,
J1r'
, , ,I ,Ni, '„i.-vtlifoitAti-tit; , ,,, , if. • • - ...- . . .
1 `{
.... — ..:i.1J4: ,r.1'1;4414:4A I_IaltiirlitiV IN 11Mi....l, 1
•
it1✓' ..a V4s..
.
1.
49 ,73
TOTAL
eSinG114114. 111m MA Who EvIsto D47O
05/21/2013 11:34 COASTAL SASH & DOOR - 9P7869539 NO.085 D01
STOR
Materials Technolo Stork Twin City Testing Corporation
Summa ry of Test Results
Product Manufacturer: Marvin Windows&Doors
r
Product Type: Aluminum Clad Woo' Sl'«ing Glass Door
Product Series/Model: Clad Ultimate Slidin rench Door(CUSFD)
12060 QXXO
Primary Product Designator:
AAMA/WDMA/CSA SD-LC35 3 2 x 2426*(143x 96*)
l01/1.S.2/A440-05
Class 1."-PG35-Size Tested 3632 x 2426*
AAMA/WDMA/CSA (143 '6*)-Type SD
101/I.S.2/A440.05
Secondary Designator; 'anadian Air lnfiltration/Exfiltration
Level=A3
Negative Design Pressure= 1920 Pa(40 dp)
Test Completion Date: / 09/16/1.0
Air Infiltration.: 0,11 cfm/ft2
Water Resistance Test Pressure: / 6.0 psf
Uniform Load Deflection Test,Pre- ure; X40
Uniform Lol*um 52.5/-60 psf
Forced'Entry
Reference must be made t' Report No TC1004455P-0162,dated 10/15/10 for complete test
s ecimen desert,Lion an detailed test results.
0 16 sfuL&foirc,a. !P. P. c n --
(?ncL ( dc )
8)0 (IL
05/21/2013 11:34 COASTAL SASH & DOOR 4 9P7869539 NO.085 P02
OP1 Stork Twin City Testing Corporation
Materials Technology ,,...�.�
PROJECT NUMBER;TCT004455P-01.62 PAGE: 1 OF 7
EAR-CONTROLLED DATA DATE: 10/15/10
STORK TWIN CITY TESTING
115 South S0 Ave
Wausau,WI 54401
IN-PLANT TESTING Of A
CLAD ULTIMATE SLIDING FRENCH DOOR(CCfSFD)
17)080 OXXO
MANUFACTURED ilY
MARVIN WINDOWS&DOORS
Prepared for:
MARVIN WINDOWS&DOORS
Attn:Mr.Skip Berneman
Highway 11 West,P.O.Bux 100
Warroad,MN 56763
Test Dates: 09/16/10
Expiration Date: 09/16/14
Prepared By Reviewed By;CI 66147
Gary Norenberg John Bordagaray
Technician Manager of Fenestration Testing
Product Testing Department Product Testing Department
Telephone: (715)848.3935 Telephone: (715)848-3935
The test results contained in this report pertain only to the specimens tested and not
necessarily to all similar products.
This document contains technical data whose export and re-export/re-transfer is subject to control
by the U.S. Department of Commerce under the Export Administration Act and the Export
Administration Regulations.
The Department of Commerce's prior written approval is required for the export re-export/re-
transfer of such technical Information to any foreign person,foreign entity or foreign organization
whether in the United States or abroad.
14.0a ar mu tatmemen%in Mtn wart mm&d yedf nrnmat niel,inkxitwlknt.nNnrapoelfautn.Ih nushodbyUkehon I and eacllxkatyexlm etlnrm;uieownrmntiouiniheTimes
or roe mmlia)WWI ktr nny porlia0er tnogax e or uae.Thin repo Is tho smadonlial property ante cthn i and may nm Ix used for nchuniaine manes This report.bon nu be
reproduced tneor in hill,O&M wril len iipprovnl of this I nbandery.lire recording of Nan,Whims or foultkittim ammo or mos on Mil nt may bo punished nonRIIVytinder
Federal Starts including Ptetaml law Tide I tl,CheSor 4)
yntrh Twin City Twins,is no c.emtina unit orSwrk Mater■uia Ta¢bnoludy II.V.,Anus ordom.The Nalhp4andw w'hioh inn member of the Steel:primp
05/21/2013 10:19 COASTAL SASH & DOOR 4 9P7869539 NO.084 D01
COASTAL, SASH AND DOOR
Fax Transmittal Form
to �l r ° FROM / p2
4'37
Name:Oki
Organization Name/Dept: . irll/tC. .f.
CC: Phone:912-352-3930
Phone number: PIc2J1 A 14 q VO—Fax:912-352.7966
Fax number: YY
Urgent Date sent 5..e,21-13
For Review Time sent
Please Comment Number of pages including cover page: A
MESSAGE:
Re: their vee- R,e,
120 V ne- 1w) Cr,
C
L-glavitO
--Ple,a5.6 Id U.s koua 64,),
[f Out_ n.e-td 0 AL9 Cc.4.cLr t h 1
04-oncehaN
Y046041, 8422 FERGUSON AVE.
SAVANNAH,GA 31406
Phone:912.352-3930
Fa:912-352-7966
05/21/2013 10:19 COASTAL SASH & DOOR 4 9P7869539 NO.084 D02
•N
r.a-
ULTIMATE SLIDING FRENCH DOOR .`.
CONSTRUCTION DETAILS WOOD
1/4'
IN 1/2-
uI9.;,i r(13)
r---1• _ Rennin Ocarina—'-..'
��, r�' ��04III;IIJIIIIIi- .i;a11.1A 4' �
I Ir �i�'rw :Ulf -=1111T �_�I 1
,..1...._ I( 1W'
IQ
— {4)1 L
�.� .. .masonry°paws -^+--1
km WOOD ULTIMATE SLIDING FRENCH DOOR
2 PANEL JAMB XO WITH ULTIMATE
WOOD ULTIMATE SLIDING FRENCH DOOR rna WI'Jr SCfiFEN
HEAD JAMB AND SILL WITH ULTIMATE r
TOP HUNG SCREEN eels or exceeds C.E.C.Air Infiltration Standards
II. ^-q WINDOW 8 D0OI1
: 7 MANUFAC'JA 8S ABsQCIATION
IIWDMA1 •
Mallmerk Certified
.rwwwdma,eom Menufocturerapokielcorionnseca azinduat.dW.Iow
AAMAIWDMAICSA11011 Is-no 1118X1924 tarn(45.5X76.76 In)
I.S.21A440-08 LC—P040 DP +qtr—so
AAMA/WOMAICSA/101/ •-Le4°
I,Sr2IA440--06 DP ' 1 , 50 1
1
5 26412m7491i8 v5rrd by 151 or more of the bias Ana RalanIs:8116598,
5 1
FL 1525
o4 K' 0
Q , =1
WOOD ULTIMATE SLIDING FRENCH DOOR
ENERGY DATA Wade, SIIGC VT CR ENERGY STAR
3/4'InsA4,un9 Clog Au 042 0.49 051 45
e
3/4'Insulming Glass LoE 272 Air 0.32 027 045 55 N,NC.SC 3
3W Insulating GIass LoE 272 A,on 0.29 026 045 59 N,NC,SC,S
3/4'',miming Class LaE Sob Au 032 018 040 56 N.NC :C'
3W lntuleim9 GIss LoE 305 Argon 0.29 0.18 040 59 N,NC,SC,5
CLAD ULTIMATE SLIDING FRENCH DOOR
ENERGY DATA U-Fector SHGC YT CR ENERGY STAR
3/4'Irnulat C,Iass Air 044 0.49 D.SI 43
3/4'fuluiotw+g Ciese LoS 272 Air 033 027 0.45 04
3/4•Insulating Grass LoE 272 Argon 030 027 045 58 N,NC,SC,5
3I4"Insuiaruro Glass LoE 366 AY .033 Q1$ 040 55
Veinisl uour Ciesc LoS 366 Non 030 O.Ia 040 58 N,NC,SC,S
41,, City of Tybee Island • Planning & Zoning Dept.
1141%.
Inspection Report num*
i 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328
o', Phone 912.472.5032 • Fax 912.786.9539 INTERZONAL
CODECOUNCIL
MEMBER
! -,
Permit No. / 3 . 9,v3 I Date Requested
Owner's Name li./ /ef.-7-7-e Date Needed
Gen. Contractor' /0A/v Aria"ie a I_ Subcontractor
Contact Information Ady.9.:pre l.1-(,A.1-a;- V/6_,)7 - 555 7
Project Address //c2D.,a \47ne-t; l
(1,,, -, ,z: / L. --(-- -. 14 ),:
...:re)
Scope of Work ,) ,,6)4a.d..- de1t4...., le A/9 4 i&lf e-t. 4-,-,r;
L '
Inspector Date of Inspection
q . /..
Inspection / /..„,,/,1_, Pass El Fai Fee
Will,
. - .
-
,, ..,.
2'Z ----1-
Inspection Pass 1:1 Fail 1:1 Fee
Inspection Pass El Fail 0 Fee
Inspection Pass 0 Fail E] Fee
/3-oa3l
City of Tybee Island, Georgia
912-472-5033 or 912-472-5031 - Fax 912-786-9539
;I APPLICATION FOR,BUILDING PERMIT
j� d�
00//
I
Property Address: D-02-, 61,CI.A` V r( ' `1- itI D/-00/
Name Mailing Address Telephone
'`_ /�( I Home: t [2. 3 t-
Owner �IeJvQiT�C� �� UK,I t- (bLAff Cell:
Architect or S ) Ct- 3/9- 11
Engineer ' l �� 31 S, c(d eo Wee 4`
Office:
Contractor 46-Nte-tt- b Y\,SO4)6_, Jak CF P j` Cell: IQ-91'7`11LL
(Check all that apply)
[Single Family ❑ Discovery/Tearout ❑ Demoliti f Structure
❑ Duplex ❑ Footprint Changes- [ 'Other
❑ Multi-Family units new square feet
❑ Commercial units heated/cooled
Details of Project: C _I a, flAre-C- L�S L elt C t1/5 U-05 .A. ► ±1 6AUsC-
,t2 Y sictoivt ode o - -
t 4 ±
kkkin hiJobtairia kykek ,A6(.1, _.
Estimated Cost of Construction: $ ash (materials + labor+ profit/overhead)
If applicable, attach a copy of the certified elevation certificate and/or survey of the property. Depending upon
the scope of the work, two sets of construction drawings and/or a site plan may be required.
Year Built: I C .13 Listed on National Historic Register or located within a National Historic District? Y / N
* Buildings older than 50 years may be eligible to be listed on the State/National Register. With this designation, you
may be eligible to take advantage of various tax incentive programs while preserving the heritage of Tybee Island.
*Also see the Tybee Island Land Development Code Article 14: Historic Preservation
During construction:
On-site re room faacilit' s will be provided through- i 01.1 S- . Construction debris will be disposed
by CO I o by means of ()l./CR.-. . I understand that I must comply with-zoning,flood
damage control, building, fire, shore protection and wetland ordinances, FEMA regulations and all applicable codes and
regulations. I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way
adversely affected as required by Article 16, Stormwater Management. I ac-•3 responsibility for any corrective action that
may be necessary to restore drainage impaired by t •s i ted constr 1$:''.
sr - • —
Date: e y �� ? Signature of App. :nt: �' � FEES
Printed Name evi-- eve- Permit
Inspections
Note: A permit normally takes 7 to 10 days to process Cap Cost Rec
Water Tap
Approvals: ture Date Sewer Stub
Planning &Zoning Manager . i�1; 3 2 6-13 Eng. Fees
Building Official Aid to Const.
Water/Sewer
Storm/Drainage
City Manager
'D f ao4. reg.. +, 2_ s-j TOTAL
rP v : c4� (��^C{o�✓i1 r estigs Ei,.L,1 4S C°4r`Q 4-I-1 �- C)/N.12-41. r v--„-.I�- ;
1 SS-cc-€d
LEAD-BASED PAINT RRP RULES
Ordinary renovation and maintenance activities can create dust that contains lead. Contractors who perform
renovation, repairs, and painting jobs in pre-1978 housing and child-occupied facilities must, before beginning
work, provide owners, tenants, and child-care facilities with a copy of EPA's lead hazard information pamphlet
Renovate Right: Important Lead Hazard information for Families, Child Care Providers, and Schools.
Contractors must document compliance with this requirement. After April 22, 2010, federal law will require you
to be certified and to use lead-safe work practices. Georgia Environmental Protection Division Lead-Based
Paint and Asbestos Program (404) 363-7026.
Projects must be done by a Certified Lead Renovation Firm AND a Certified Renovator
When disturbing lead-based painted or coated surfaces or components more than 6 ft2 per interior
room or 20 ft2 of exterior surfaces AND all window replacements and partial demolitions of any size.
* * * * * * * * * * *** * * * * * * * *
Asbestos/Environmental Notification to Georgia EPD for
Projects Involving Demolition, Wrecking, or Renovation
The undersigned hereby acknowledges that the issuance of this permit does not in any way grant permission
to the owner, owner's representative, or permit holder to proceed with demolition, wrecking, or renovation of a
structure prior to the filing of any required ten (10) day "Project Notification for Asbestos Renovation
Encapsulation or Demolition" form in accordance with the Georgia Asbestos Rules. The Georgia
Environmental Protection Division administers the rules. In most cases, the rules require both the owner and
the involved contractors to assure the portion of the building involved in the project is thoroughly inspected by
an Accredited Asbestos Inspector for materials that contain asbestos; and the removal of the asbestos before
renovation, wrecking, or demolition begins almost without exemption. Georgia EPD requires a completed
demolition notification from be submitted 10 workings days in advance even if no asbestos is present in the
building. Further guidance for regulatory compliance and contact telephone numbers are provided by the
brochures entitled Asbestos & Renovation and Asbestos and Demolition. Other environmental issues such
as asbestos removal techniques, lead'abatement, ground contamination, or unusual site conditions may have
EPD regulations that could affect the project;
* * * * * * * * * * * ** * ** ** * * *
BMPs
While BMP deficiencies are not necessarily the fault of the owner or his agent, BMPs are their responsibility.
Two areas of deficiencies are in the most basic and common BMPs; Co — Construction Exit and Sd1 —
Sediment Barrier. Correct installation information can be found in the Field Manual for Erosion and Sediment
Control in Georgia, Fourth Edition 2002, Georgia Soil and Water Conservation Commission;
http://www.gaswcc.org/docs/field_manual_4ed.pdf.
Problems with the Co is not limited to the installation, but to material. The stone will be a representation of
1.5"-3.5" stone or larger.
Type A sediment barriers have been installed where Type C is required and shown on the permit drawings.
Where two rows are called for they will be installed with a separation that allows for the first one to fail (fall
over) without impacting the s cond one. The complete assembly and installation must be compliant; steel or
wo pos ost spacing, pe C or A.
:0/4/1/
Signature for receipt of Lead Paint, Asbestos, and BMP notices. Date
26, 3 /4/• 1./e.";€6
Printed Name
Chatham County Board of As sors: 2012 Property Record Card 4-001 ' 01-001 Page 1 of 3
2012 Chatham County Board of Assessors 4-0011-01-001
Property Record Card 1202 VENETIAN DR TYBEE ISLAND
!APPRAISER pdwillia LTS 348 349 348 A+349 A WD 4 TYBEE EVERETTE ROBERT H&SUZANNE R* CAMA ASMT
I LAST INSP 05/27/2007 13224 OLD COFFEE BLUFF RD 362,400 362,400 LAND 3
IAPPR ZONE 000008 SAVANNAH GA 31419167,600 67,600 BLDG 2
70,500 70,500 OBXF 6
500,500 500,500 Cost-MS
'SALES BOOK/ INS VI QU RSN PRICEk '. CODES
PAGE \ r a r •;. PROPERTY 0006 RESIDENTIAL
19 Jan 301A 0560 QC I U UQ . N: f` •r USE
2006 ^ ;'..4.:",•-'_ r� SF x ° ' • UTA 0004 Tybee Island•
GRANTOR:EVERETTE ROBERT H&SUZAN 'Si' ., _+ r « w'�
GRANTEE-EVERETTE ROBERT �j/ � ., •1:4 p,i t i'4 NBHD 020222.00 T222 TYBEE
,� �+:4moo , 1 � HORSE PEN
2006 n 301A 0577 NA I U UG I w F..x y A fr,,; EXEMPTIONS Y
GRANTOR:EVERETTE ROBERT + --I - ''
GRANTEE:EVERETTE ROBERT H&SUZAN i ~:4 -; HISTORY LAND IMPR TOTAL
21 Jan 282K 0209 WD I Q QW 575,000 Ws.
x"a ' 3��i 2011 362,400 155,000 517,400 Cama
2005 a It' ]
,�`, t+, 2010 478,700 155,000 633,700 Cama
GRANTOR:T/SON ERNESTINE M _ 11107".• 2009 504,500 145,500 650,000 Over
'' GRANTEE:EVERETTE ROBERT H&SUZAN r t
l_ .. , 2008 504,500 145,500 650,000 Over
05'23 2007'.' 2007 650,000 A/C
PERMITS TYPE DATE AMOUNT .,
06-0509 DK 30 Jan 2007 Insp 72,000 2006 433,000 77,000 510,000 Cama
05-0302 GM 01 Jan 2006 Comp 2,000 [Click for larger picture] 2005 311,000 88,000 399,000 Cama
040361 RF 01 Jan 2006 Comp 2,200
2004 276,500 101,000 377,500 Cama
---- - 2003 260,500 87,000 347,500 Cama
L+ /�G 1 or-r--, a am County
COMMENTS: a�7/�► 1 2002 197,000 85,000 282,000 Cama
�. . Tax Commissioner
120 Jun 2006 *JOINT TENANTS W/RIGHT OF ri.+u '+,,:, Property Tax Statement X 2001 159,000 76,000 235,000 Cama
SVRS 2000 79,500 76,500 156,000 Cama
.17 Aug 2005 *TY06 SURVS 11999 79,500 76,500 156,000 Cama
1998 79,500 65,500 145,000 Cama 1
1997 139,500 A/C
' 1996 37,800 56,320 94,120 Over
1995 37,800 56,320 94,120 Over
1994 37,800 56,320 94,120 Over
1993 37,800 56,320 94,120 Over
11992 37,800 56,320 94,120 Over
EXTRA FEATURES
ID# BLDG# SYSTEM DESC DIM 1 DIM 2 UNITS QL UNIT PRICE RCN AYB EYB DT ECON FUNC SP SP% RCNLD MKT VALUE
1140765 86537 WOOD DECK AV 8 32 256.00 A 7.98 2,043 1990 1990 2R 429 400
140766 86537 Slab w/walls Under 0 0 336.00 A 12.49 4,197 1990 1990 IR 3,316 3,300
140767 86537 AV CPT FLAT/SHED RF 0 0 912.00 A 8.43 7,688 1990 1990 IR 6,074 6,100
140768 86537 2"Decking/w post,pi 6 448 2688.00 G 23.55 63,302 2006 2006 2R 53,807 53,800
!140769 86537 Dock roof MTL 16 16 256.00 G 6.10 1,562 2006 2006 2R 1,328 1,300
140770 86537 2"FLoating/w post,pi 12 24 288.00 G 22.88 6,589 2006 2006 2R 5,601 5,600
!LAND 7
ID# USE DESC FRONT DEPTH UNITS/TYPE PRICE ZONING LCTN TOPO OTHER ADJ1 ADJ2 ADJ3 ADJ4 MKT VALUE
1111129 MARSH VIEW 0 0 4,500.00-SF 62.00 R2 V50 221800
1111130 MARSH VIEW 0 0 6,300.00-SF 62.00 R2 SZ-50 103500
1111131 MARSH VIEW 0 0 1.00-G 70000.00 R2 37100
��J / °700'
V U /s .
http://boa.chathamcounty.org/DesktopModules/ChathamCountyBoardofAssessors/Prope... 03/26/2013
Chatham County Board of As—sors: 2012 Property Record Card 4-00' " -01-001 Page 2 of 3
2012 Chatham County Board of Assessors 4-0011-01-001
Property Record Card 1202 VENETIAN DR TYBEE ISLAND
BUILDING SECTION j CONSTRUCTION TYPE RCN AYB EYB DEP TYPE PHYS ECON FUNC OBSV/% TOTAL DEP% RCNLD U.FACTOR MKT VAL 1
86537-1-2012 1Residential 94,708 1981 1995 MS 15.00 0.00 0.00 0.00 15.00 80,502 1.05 67,600
SECTION TYPE 1-Main
10' 14' 15' 8' AREA 1248
TYPE 1-Single-family Residence
12' 12' 'FRAME 1-Stud Frame
U
• NDR !STYLE 1-One Story
Slab wAValls under I QUALITY 3.00
iti CONDITION 3.00
Race Living Area ' I#UNITS 0
32 168 ' 3 ' 1#OF BEDS/BATHS 2/2.00
■CPT OPEN —"
14
carport Open Area COMPONENTS Units % QUAL
i III Si /WAD R1 108 Frame,Siding,Wood 100.00
Base 1.1%jog Area Wood Deck R2 208 Composition Shingle 100.00
1 ' 912 12' 256
U LNDR R3 352 Heat Pump 100.00
Slab w!W'al�
under R4 402 Automatic Floor Cover Allowance
8 R6 601 Plumbing Fixtures(#) 10.00
R6 602 Plumbing Rough-ins(#) 1.00
168 R6 622 Raised Subfloor(%or SF) 100.00
[Click for larger picture] R6 641 Single 1-Story Fireplace(#) 1.00
http://boa.chathamcounty.org/DesktopModules/ChathamCounty/BoardofAs ses sors/Prope... 03/26/2013
Chatham County Board of As sors: 2012 Property Record Card 4-001 ' •01-001 Page 3 of 3
2012 Chatham County Board of Assessors 4-0011-01-001
Property Record Card 1202 VENETIAN DR TYBEE ISLAND
BUILDING SECTION:CONSTRUCTION TYPE RCN AYB EYB DEP TYPE PHYS ECON FUNC OBSV/% TOTAL DEP% RCNLD U.FACTOR MKT VAL
86538-1-2012 Drawing Only NaN MS 0.00 0.00 0.00 NaN NaN
CCOMPONENTS Units % QUAL
16' 12 '
1 1¢ '
BD1
256
2' ' 24
BD3
16, 288
12 '
[Click for larger picture]
BD1-DOCK/DOCK ROOF BD2-WALKWAY BD3-FLOATING DOCK WALKWAY IS
6X448
http://boa.chathamcounty.org/DesktopModules/ChathamCountyB oardofAssessors/Prope... 03/26/2013