HomeMy Public PortalAbout10-0333 North Beach Grill 4 P CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 06-23-2010 PERMIT#: 100333 WORK DESCRIPTION MECH-3 HOODS ONLY WORK LOCATION 33 MEDDIN DR OWNER NAME NORTH BEACH GRILL ADDRESS 1501 CHATHAM AVENUE CITY,ST,ZIP TYBEE ISLAND GA 31328-2842 PHONE NUMBER 912-786-9003 CONTRACTOR NAME SAVANNAH METALWORKS,INC ADDRESS PO BOX 3509 CITY STATE ZIP SAVANNAH GA 31414 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 92.00 PROPERTY IDENTIFICATION# PROJECT VALUATION $9,345.00 TOTAL BALANCE DUE: $ 92.00 It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire, soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: � P.0.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328 (912)786-4573-FAX(912)786-9539 www.cityoftybee.org °. z City o' lbee Island • Community Develi lent Dept. EP& � l s Inspection Report ou \,� '`// 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 INTERNATIONAL A,_/ Phone 912.786.4573 ext. 114 • Fax 912.786.9539 CODE COUNCIL MEMBER Permit No. i /--) .„ Date Requested c43/ / i Owner's Name O'1 .;fr -A-z-"? .4 / 2I i Date Needed � ,�� Gen. Contractor ° 1 ,i). 4', Subcontractor Contact Information )44/0/1 /)iZ 7A-i 2.344 'JL 2°D Project Address -4`2, /A1 ELI il Scope of Work /(12- )1._ Inspector ' . li 'I b Date of Inspection Inspection {` • Pass ` p _r. C H i I •- . al ❑ Fee Inspection Pass ❑ Fail 0 Fee Inspection Pass ❑ Fail 0 Fee Inspection Pass ❑ Fail ❑ Fee � , City o bee Island •• Community Devei ' )ent Dept. 1��� '~> `,, , Inspection Report amnia 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 -�" `h Phone 912.786.4573 ext. 114 • Fax 912.786.9539 CODECOUNCIL MEMBER Permit No. I 0 - 0--- .3-.2 Date Requested cS 2//u Owner's Name i\, 07,71-17,� -1 1, i i LLG Date Needed /�' ii a Gen. Contractor Subcontractor Contact Information "; 44-,0,) biz. 1-47-0-fri 34 • IZZO Project Address 33 tom) PLDT) Scope of Work cci i__ (3) it Inspector Date of Inspection Inspection r, 1-, i.)A -- Pass El Fail y;�„,o-Fe- \--039/e-10,112, 01\) elp: - 1 Ke> DoL5\P-1-- (Pa,/ Rxe-- . 1 Inspection Pass ❑ Fail 0 Fee Inspection Pass 0 Fail 0 Fee Inspection Pass 0 Fail 0 Fee 00 g "� City of( `)ee Island • Community Deveic' ent Dept. ��`•� W Inspection Report ',� ���403 Butler Ave. • P.O. Box 2749 • Tybee Island GA 31328 =�,Island, INTERNATIONAL Phone 912.786.4573 ext. 114 • Fax 912.786.9539 CODE COUNCIL MEMBER Permit No. 10 - 0 3 5;� Date Requested C C% ho Owner's Name , b i k -. ZipA e: Date Needed '7)'`'`/- 41-- cz 4vv"J 1/a• s Gen. Contractor Subcontractor ) 1 11ia`J ( 1,00zi . S Contact Information /n-irkiikk. a Z>d -`'I 22.7) Project Address 3.3 I }J \ 5iZ) (),; _ Scope of Work ° �----c)i`) I A ; 1i - ("3 ) Inspector Date of Inspection - Inspection Li6 - 4 ---H E<54-4- Pass 12/Fail Fee r Inspection ~ Pass a I Fe 'Vd ( Z Fievs vbriz --w4rci2c-1-1) 0 ,#.> \01 �/0&s ' �`\\\ Inspection _ i ---4- \ P ss Fail 0 Fee v�Ni s C,Ztji:� . ,) I N 15t4 I 1 1 ,Ky.� `' Inspection Pass ❑ Fail ❑ Fee A t 3(1 I - d LigL4 MAR-09-2007 08:31 CITY OF TYBEE ISL. ylt un ,�_, 1 .ul. ■_,l M •' CITY OF TYBEE ISLAND ,4 • a, BUILDING & ZONING DEPAR'I'MNET P.O. Box 2749 k 1 Tybee Island, GA 31328 k ►. Ph ne (912) 786-4573 Fax (912) 786-9539 ('0 -03 3 3 PL- PERMIT APPLICATI ON Date . June 22, 2010 - North Beach Bar & Grill 33 Meddin Dr. , Tybee Island Location of work(street address) _ GA 31328 Contractor Savannah Metalworks, Inc, Address of Contractor P.O. Box 3509, Savannah, GA Telephone number of Contractor - 912-234-_922_9_ - -Tar.7_,_._^r' - Name of Property Owner Mr. George Spriggs -. Mailing address of Property Owner 1501 Chatham Ave. , Tybee Island, GA 31328 Telephone number of Property Owner 912-429-0760 _ Date work will be ready for inspection, if known Permit Number lstimatedcost ofconstruction Bldg Permit_ # 1 0-0246 X9-, 345. 00 New Work Replacement Oil Gas _ -Electric Backflow Preventor Disposal Unit _ Domestic Water Connection to Main • Drain Roof or Area Drainage or Vent Piping _ xx Fire Protection Sprinkler System; Number of llcads/Nozzles g EACH Grease/Oil Trap Hose Bib Hot Water Heater Icemaker Lawn Sprinkler System • _ Plumbing Fixture Residential House Sewer Connection to Main Sewer Cleanout Sewer Stub _ _ -- _ ------ ---- - Vacuum Breaker Water Meter - . Water Service Line-New Residence Water Service Line-Replacement Water Softener xx _ Other Installation of 2 Each 10 ' ft Exhaust Hoods & 1 8 9 ' . asher Condensate Hood. Fab & Install duct work for hoods . L 1 LA302 C--2 1)5 401 Cif � 6 kJ ( E. C21J ` tZ r-�-- *- 5 1 TOtAL P.01 Mr7P-o9--2go7 08: 11 C I 1 Y OF TYBEE 9W. 2 b F.n1 205-380-2902 To: 1-912-238-0120 912 238 0120 ( 1 or 'a) D (..aa.,r"14(4* SHOP DRAWING "An ApP►uv .� 4 ' Remain on I lI t EACH GRILL TO: SAVANNAH RESTAURANT EQUIPMENT ATTN: ARNALDO(ARNY)TORRES REVIEW FOR CODE COMPLIANCE FAX: 912-303-9476 Every effort has been made to identify code violations, no oversight by the reviewer shall be construed as authority SUBMITTED BY: NATHAN SANDLIN to violate, cancel, alter or set aside ' any applicable codes or ordinances.The review and permit should not be construed as a warranty or ua antee. PAGES: 8 (Including This Cover Sheet) Reviewed By Date 43//b Following are the Shop Drawings you requested for the above referenced Quote Number. If there are any changes needed to these drawings or quote, please contact NATHAN SANDLIN at (800) 322-4036 or email at NATHANALARKINHOODS.COM stuawpuawy eiBaoaO �o amts pus uoitip3Z'apo3 olI oaiB leuofteN 641141m Aldwoo `-- • ;emu suoftellet5ul IeofatoaiB IIY C—CDPV( All construction must comply with The International Building Code2, Edition and State of Georgia Building Amendments • • All HVAC installations must comply with The International Mechanical International Fuel Gas Codedltlons and State of Georgia Amendments LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 1 JUN-16-2010 11:21 205 388 2902 91: P.01 205-380-2902 To: 1-91Z-djtj-uizu y.iz Gio UlGU Date 06/16/2010 SECTION VIEW Ref. #.: L-244777 Job Name: NORTH BEACH GRILL Model: EOLC-BR (EXHAUST ONLY LOW CEILING-BACK RETURN) HANGER BRACKET EXHAUST COL i_AR 1/1L7L 'CLASSIFIED UL US1EU LIGHT 24' FILTER REMOVABLE GREASE TROUGH p_ .v,. GREASE CUP } BAcK RETURN PLENUM t w HOOD SIZE &CONFIGURATION, HOOD 1 LxWxH 0 20 0"x 54"x 24" /20"Front WALL STYLE - HOOD IS 2 SECTIONS, END TO END MATERIAL FILTERS LIGHTS 430 STAINLESS STEEL Where Exposed Stainless Steel Baffle Filters 6 Prewired Incandescent Light(s) SECTION 1 10' 0"x 54"x 24" WEIGHT: 511Ibs 600 Degree ETL Label (Conforms to ANSI/UL-710) COLLARS (See Plan View for Size&Location) BACK RETURN PLENUM 'Wall Mounted Ansui R-102 Wet System Including up to 2"Mechanical Gas Valve Automatic Fan Controller per IMC 507.2.1,1 LH-END • Stainless Steel Baffle Filters CFM REQUIRMENT: EXHAUST: 3000 CFMS @ .625 S.P. NOTE S.P. Calculations Include Hood, Filters, and up to 8'of Straight Exhaust Duct. SUPPLY: 2199 CFMS @ .250 S.P. NOTE S.P. Calculations Include Hood and up to 20'of Straight Supply Duct. SECTION 2 10' 0"x 54"x 24" • WEIGHT: 511Ibs 600 Degree ETL Label (Conforms to ANSI/UL-710) COLLARS (See Plan View for Size& Location) BACK RETURN PLENUM Ansul Piping Heat Sensor Mounted In Hood RH-END Stainless Steel Baffle Filters LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 2 EOLC-BR JUN-16-2010 11:21 205 380 2902 93: P.02 205-3,80-2902 •1'o: 1-91 - .3ti-Uizu J16 £ b ui6u Aw _ Date 06/16/2010 d 'AlriC TAr a}'.` SECTION VIEW Ref. #.: L-244777 Job Name: NORTH BEACH GRILL Model: EOLC-BR (EXHAUST ONLY LOW CEILING-BACK RETURN) Continued From: Page 2 CFM REQUIRMENT: EXHAUST: 3000 CFMS @ .750 S.P. NOTE ' S.P. Calculations Include Hood, Filters, and up to 8' of Straight Exhaust Duct SUPPLY: 2199 CFMS @ .250 S.P. NOTE • S.P. Calculations Include Hood and up to 20' of Straight Supply Duct. • NOTES: LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 2 Cont EOLC-BR JUN-16-2010 11:21 205 1'90 2902 91> P.03 205-380-2902 To: 1-91 -238-01x0 91z eib uiau LY U1 7 ) 1.0-L„1„ ,,., . 4_,w _ Date • 06/16/2010 fi7Eu., PLAN VIEW Ref. #,: L-244777 Job Name: NORTH BEACH GRILL Model: EOLC-BR (EXHAUST ONLY LOW CEILING-BACK RETURN) SUPPLY COLLAR()SMPPEDLOOSE - SUPPLY COLLARS/SHIPPED LOOSE 5' O p p ( 0 EXHAUST COLLAR'S)SIPPED LOOSE EXHAUST COLLAR(S)SHIPPED LOOSE 19'MAX TYIP 1 ID? WI I SECTION 1 SECTION2 LI T Lt L3 HOOD SIZE &CONFIGURATION HOOD 1 20'0"x 54"x 24" /20"Front WALL STYLE- HOOD IS 2 SECTIONS, END TO END DIMENSION DATA L1 - 10'0" L2 - 10'0" L3 - 20'0" W1- 54" W2- 60" SECTION 1 10'0"x 54"x 24" 1 - 16X16 -Exhaust Collar Shipped Loose 2 -24X6 -Supply Collars Shipped Loose SECTION 2 10'0"x 54"x 24" LEGEND 1 -16X16 -Exhaust Collar Shipped Loose EXHAUST COLLAR / 2-24X6 -Supply Collars Shipped Loose SUPPLY COLLAR >-< HANGER 1 ■ 2' y r- •TYP.REAR HUNGERS' I 3.5• • HANGERS ARE 1.5'x 5'TYP.' -\ 2'---1 -- •TYP,FRONT HANGERS' 11 9" NOTES: T LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 3 PEO-EE-BR JUN-16-2010 11:21 205 360 2902 91: P.04 205-380-2902 To: 1-91Z-djt3-U1GU '11c c.in u.I. 0 Date • 06/16/2010 ES rkifi ►u SECTION VIEW Ref. # : L-244777 Job Name: NORTH BEACH GRILL Model: CH1 (STANDARD CONDENSATE HOOD) HANGER EXHAUST COLLAR !I EACH CORNER ALUMINUM MESH FILTER(OPTIONAL) 24 (SEE OPTIONS) CONDENSATE DRAIN PLUG CONDENSATE TROUGH I r ` ) i '1 - W -- -- -F"- HOOD SIZE & CONFIGURATION HOOD 2 LxWxH 3'6"x 42"x 18" WALL STYLE - HOOD IS 1 SECTION, STAND ALONE MATERIAL FILTERS LIGHTS 304 STAINLESS STEEL Where Exposed Aluminum Mesh Filter(Shipped None SECTION 1 3'6"x 42"x 18" WEIGHT: 1581bs No ETL Label COLLARS (See Plan View for Size & Location) Aluminum Mesh Filter(Shipped Loose) CFM REQUIRMENT: EXHAUST: 615 CFMS @ .250 S.P. NOTE • S.P. Calculations Include Hood, Filters, and up to 8'of Straight Exhaust Duct. SUPPLY: n/a NOTES: LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 4 CH1 JUN-16-2018 11 21 205 380 2902 91% P.05 205-380-2902 To: 1-912-238-0120 91z zit3 U1zU 1b oT ' 1 Ub to U�.0 ; Date 06/16/2010 ,,,,4501 407#0, : PLAN VIEW Ref. # : L-244777 Job Name: NORTH BEACH GRILL Model: CH1 (STANDARD CONDENSATE HOOD) I EXHAUST COLLAR(S) LOOSE V1 LI HOOD SIZE&CONFIGURATION HOOD 2 3'6"x 42"x 18" WALL STYLE - HOOD IS 1 SECTION, STAND ALONE DIMENSION DATA L1 - 3'6" W1- 42" SECTION 1 3'6"x42 "x18 " 1 -11X11 - Exhaust Collar Shipped Loose LEGEND SUPPLY COLLAR >`\ HANGER Q 2..5 'TIP.HANGERS' I HANGERS HAVE 9116'HOLE FOR HANGING ROD_ 0 NOTES: LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 5 PCHOH-SA1 JUN-16-2010 11 21 205 380 2902 91: P.06 205-3,80-2902 To: 1-912-238-0120 912 238 0120 < < GI ' ) vo-io-c.vly . "j t 1. r , , Date • 06/16/2010 ; ,,, + r6 * ETL-705 SUPPLY FAN Ref. #.: L-244777 Job Name: NORTH BEACH GRILL B t-- G—► + ,2' E r -rwr- ' f f ,-- D } ' F I A np. -- - o.t„ ROOF CURB BLOWER OPENING 11)us 12"TALL ROOF CURB 1if FAN CURB STANDARD FEATURES: Heavy Gauge DIMENSIONAL DATA SIZE FILTER Housing • Easily Removable Cover MODEL A B C D E F G H I SIZES • Corrosion Resistant Fasteners ARS id 34" 34" 35" 30" 11118" 13118" 18" 33" 33" (2)165(25"x1" 'Constructed of Galvanized Steel (Painting not Required).Double Inlet Supply Blower, Belt Driven, Mounted on Vibration Isolators • Cast Iron Motor and Fan Drives•Factory Mounted Disconnect Switch•Permanently Lubricated Bearings •Cleanable Aluminum Mesh Filters• ETL Listed FANS 2 And 3 For Hood: 1 SECTIONS: 1 & 2 QUANTITY MODEL CFMS Si'. H.P.. VOLTAGE PHASE AMPS WEIGHT 2 ARS-10 2199 625 3/4 230 1 6 90 230 OPTIONS 33X33X12 Sloped Roof Curb 1/12" LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 6 ARS1-FAN JUN-16-2010 11:21 205 380 2902 91% P.97 2U5-it10-cUG 10: 1-/16-4Jo-ujGV 71G GJo V1GV vv Date * 06/16/2010 DIRECT DRIVE EXHAUST FAN Ref. #.: L-244777 Job Name: NORTH BEACH GRILL - e STANDARD FEATURES: Roof Exhaust Fans Shall Be i Centrifugal Direct Drive Type•The Fan Wheel Shall Be Centrifugal Backward Inclined, Constructed Of Aluminum And Shall Include A Wheel Cone Carefully Matched To The Inlet Cone For Precise Running Tolerances'Wheels Shall Be Statically And Dynamically Balanced•The Fan Housing And Shroud Shall Be Constructed Of Heavy Gauge Aluminum•The ' V A Fan Housing And Shroud Shall Be Constructed Of Heavy Gauge Aluminum With A Rigid Internal Support Structure-The — Fan Shroud Shall Have ARolled Bead For Added Strength• °m" CM," Motors Shall Be Mounted Out Of the Airstream On Vibration MN N,!. - Isolators•Fresh Air For Motor Cooling Shall Be Drawn Into The — J ' Motor Compartment From An Area Free Of Discharge Contaminants•Motors Shall Be Readily Accessible For C U)US LISTED I } �. ._. Maintenance•A Disconnect Switch Shall Be Factory Installed T Sq, JJJ And Wired From The Motor Compartment For Ease Of Electrical Wiring•AIl Fans Shall Bear The AMCA Certified FAN CURB Ratings Seal For Sound Air Performance•Each Fan Shall Bear DIMENSIONAL DATA SIZE A Permanently Affixed Manufacturer's Nameplate Containing Model Number And Serial Number For Future Identification MODEL A B G SQ. H 1 095 14-5/8' 21-314" 1-3/4" 17" 16" 16" FAN 1 For Hood' 2 SECTION: 1 QUANTITY MODEL CFMS S.P.. H.P.. VOLTAGE PHASE AMPS WEIGHT 1 XRED-095-D 615 .500 1/8 115 1 .00 26 OPTIONS 16X16X10 Sloped Roof Curb 1/12" • • LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 7 XRED-FAN JUN-16-2010 1121 205 390 2902 91% P.09 205-380-2902 To: 1-912-238-0120 912 238 0120 ( 9 or '3 ) u; : �� lV. Date 06/16/2010 r �' f. UL-762 EXHAUST FAN Ref. # : L-244777 Job Name: NORTH BEACH GRILL STANDARD FEATURES: All Aluminum Housing• Backward Inclined Wheel•Top Cap with Stainless _I Steel Fasteners•One Piece Wind Band Continuously Welded to The Curb Cap•Prepunched Mounting Holes ■ soil a Drain Trough•Internal Conduit Chase-Lifting Points. 'U! � Permanently Lubricated Ball Bearing Motors•Static A Resistant Belts•Adjustable Pitch Drives•Bearings Rated at 500,000 Hour Average Life•Motors Matched to Fan Load Mounted Out of Airstream•NEMA-1 i ./'`ibiur7 Disconnect Switch C ® US LISTED a T Sq FAN CURB DIMENSIONAL DAM SIZE MODEL A B C G sa H I 161 19.318' 28.718" 29-3/4' 1-314" 22' 21' 21' FANS 1 And 2 For Hood: 1 SECTIONS: 1 & 2 QUANTITY MODEL CFMS S.P.. H . VOLTAGE PHASE AMPS WEIGHT 2 XRUB-161-10 3000 .875 1 208 1 8.00 87 OPTIONS Grease Trough for Exhaust Fan Hinged Base Kit for Exhaust Fan 21X21X24 Vented Sloped Roof Curb 1/12" LARKIN INDUSTRIES, INC. - 114 David Green Road - Birmingham, AL 35244 Page 8 XRUB-FAN JUN-16-2010 11 21 205 380 2902 917. P.09