Loading...
HomeMy Public PortalAboutLOVELL AV_1008 (3) ` 6 r }} ,E ' CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 04-22-2013 PERMIT#: 130258 I WORK DESCRIPTION ACCESSORY STRUCTURE WORK LOCATION 1008 LOVELL AVE 1 OWNER NAME MICHAEL&CATHLEE CAMPBELL ADDRESS 1008 LOVELL AVE CITY,ST,ZIP TYBEE ISLAND GA 31328 PHONE NUMBER CONTRACTOR NAME MICHAEL&CATHLEE CAMPBELL ADDRESS 1008 LOVELL AVE CITY STATE ZIP TYBEE ISLAND GA 31328 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 100.00 PROPERTY IDENTIFICATION# PIN#4-0006-14-003 PROJECT VALUATION $2,700.00 TOTAL BALANCE DUE: $ 100.00 It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire,soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: 96/)/1. P.O.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328 (912)786-4573-FAX(912)786-9539 www.cityoftybee.org 1 CA 0 L L 5 7' ,,,. `�� City of Tybee Island • Community Development Dept. ��=� Inspection Report mum* 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 =�:i INTERNATIONAL Phone 912.472-5032 • Fax 912.786.9539 CODE COUNCIL MEMBER Permit No. 43 " P� 51 Date Requested 06/9/7 h3 Owner's Name eA1flfØfL1 Date Needed '06 N1i3 Gen. Contractor �J Subcontractor AI Contact Information /Re efV7P6E/—L 304 - c276 ° 5 311 Project Address 100 ? Ii) (1/ LL Scope of Work AtTS4 'Y 3i UC-tU t, i r` Inspector -1/(i Date of Inspection (.-7(4-')/'.$ Inspection r iNI A-c... Pass a Fail ❑ Fee Z � {- ` \ ,_ 11>',- ! i.'Z ,;; ( I.e? V� rZ i' ""6--) I-c2.--1--• 0-7, -,-;i 6 ,t. ,!7 i° i,---4. t:tom. t 1 1 -^ Inspection Pass ❑ Fail ❑ Fee Inspection Pass ® Fail ® Fee Inspection Pass 0 Fail 0 Fee c,„ (0 f Handy Home Products,Sequoia 12 ft.x 12 ft.Wood St-rage Building Kit with Floor, 18203-7 at The Home Depr,*-Mobile 3/7/13 10:57 AM Stores Account Cart Search Products I III _ o_ '/2...x 1/= Lal 6 to%is Lem-S S pQc .W 4)-q,ct j ,p f,I +C.3 Online Exclusive $2,639.00 /EA-Each Handy Home Products Sequoia 12 ft. x 12 ft. Wood Storage Building Kit with Floor Free Shipping Ship Pick Up in Store ADD TO MY LIST My Store Aisle Store Qty. Cumberland#121 -- NA http://m.homedepot.com/p/Handy-Home-Products-Sequoia-12-ft-x-12-ft-Wood-Storage-Building-Kit-with-Floor-18203-7/100592130/ Page 1 of 4 Handy Home Products,Sequoia 12 ft.x 12 ft.Wood S*^rage Building Kit with Floor, 18203-7 at The Home Depot-Mobile 3/7/13 10:57 AM Reviews Not Yet Rated Description Specifications Approximate 12 Shed Depth (ft.) : Approximate 12 Shed Width (ft.) : Assembled Depth 144 in (in.) : Assembled 132 in Height(in.) : Assembled Width 144 in (in.) : Assembly Full Required : Door Opening 5 Width (ft.) : Lockable Yes Door/Gate Latch : Manufacturer 15 year Limited Warranty Warranty : Number of Doors 1 Number of 0 Windows : Portion of 98 product made from wood (%) : Product Depth 144 in (in.) : Product Height 132 in http://m.homedepot.com/p/Handy-Home-Products-Sequoia-12-ft-x-12-ft-Wood-Storage-Building-Kit-with-Floor-18203-7/100592130/ Page 2 of 4 Handy Home Products,Sequoia 12 ft.x 12 ft.Wood •^rage Building Kit with Floor, 18203-7 at The Home Dept-Mobile 3/7/13 10:57 AM (in.) : Product Weight 1998 lb (lb.) : Product Width 144 in (in.) : Returnable : 90-Day Roof Color Light Brown Wood Family : Shed Door Type : Double Shelving Included No Sidewall Height 84 (in.) : Siding Color Beige/bisque Family : Storage Capacity 1444 (cu. ft.) : Vendor 5 Processing Days Shipping Options Most orders process within 5 business days This item is also available for pick up in your local store (FREE) within 4-7 business days, plus order processing time Please allow an additional 2-6 business days for Curbside Truck http://m.homedepot.com/p/Handy-Home-Products-Sequoia-12-ft-x-12-ft-Wood-Storage-Building-Kit-with-Floor-18203-7/100592130/ Page 3 of 4 Handy Home Products,Sequoia 12 ft.x 12 ft.Wood C -rage Building Kit with Floor, 18203-7 at The Home Dep^'-Mobile 3/7/13 10:57 AM Delivery in the Continental U.S. Deliveries are made to receiving area/dock for Businesses or curbside for Residential orders. Delivery appointments are required. Cumberland, #121 (Edit) Account (Sign In) Home Depot Videos Call Customer Service Deals Home Depot Services Full Site i Help Terms i Privacy Feedback http://m.homedepot.com/p/Handy-Home-Products-Sequoia-12-ft-x-12-ft-Wood-Storage-Building-Kit-with-Floor-18203-7/100592130/ Page 4 of 4 /e3-D��� 9 City of Tybee Island, Georgia , 912-472-5033 or 912-472-5031 - Fax 912-786-9539 �) APPLICATION FOR BUILDING PERMIT Property Address: /0 D i 'V- 0006 -iii, D03 Name Mailing Address Telephone �� 6‘A 00 Lzo.eL\,A e Home: Owner t� . �t�,r Cell:30q-YNe '-S3 1c? Architect or Engineer Office: Contractor 0 '- Cell: (Check all that apply) [Single Family ❑ Discovery/Tearout ❑ Demolition of Structure ❑ Duplex ❑ Footprint Changes– ❑ Other ❑ Multi-Family units new_square feet ❑ Commercial units heated/cooled i Details of Project: (,JQ - -0 C240 CA cCc€SSCJNN ►0 U 0 i`vL? O' e eva-Ire cieCk t p f D/6 1) sr i -i1 , -1azi ►off ` yr rJ- 06 v,Tzl r i5j Estimated Cost of Construction: $ al 0 0 (materials + labor+ profit/overhead) If applicable, attach a copy of the certified elevation certificate and/or survey of the property. Depending upon the scope of the work, two sets of construction drawings and/or a site plan may be required. Year Built: I R.7 S Listed on National Historic Register or located within a National Historic District? Y / *Buildings older than 50 years may be eligible to be listed on the State/National Register. With this designation,you may be eligible to take advantage of various tax incentive programs while preserving the heritage of Tybee Island. *Also see the Tybee Island Land Development Code Article 14: Historic Preservation During construction: On-site restroom facilities will be provided through . Construction debris will be disposed by by means of . I understand that I must comply with zoning,flood damage control, building,fire, shore protection and wetland ordinances, FEMA regulations and all applicable codes and regulations. I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected as required by Article 16, Stormwater Management. I accept responsibility for any corrective action that may be necessary to restore drainage impaired by this permitted construction. ''`` Date: '`�'-1 t` 13 Signature of Applicant 'S kC�" Gr-L-Qi� FEES Printed Name ∎e-`'`0. t kk ' C -e k Permit ti> [ OLD Inspections Note: A permit normally takes 7 to 10 days to process Cap Cost Rec Water Tap Approvals: ig- - u - Date Sewer Stub Planning &Zoning Manager ,_— f. g . Z _ Eng. Fees Building Official ��' i L /S– Aid to Const. _ Water/Sewer Storm/Drainage City Manager TOTAL ` ( O D LEAD-BASED PAINT RRP RULES Ordinary renovation and maintenance activities can create dust that contains lead. Contractors who perform renovation, repairs, and painting jobs in pre-1978 housing and child-occupied facilities must, before beginning work, provide owners, tenants, and child-care facilities with a copy of EPA's lead hazard information pamphlet Renovate Right: Important Lead Hazard information for Families, Child Care Providers, and Schools. Contractors must document compliance with this requirement. After April 22, 2010, federal law will require you to be certified and to use lead-safe work practices. Georgia Environmental Protection Division Lead-Based Paint and Asbestos Program (404) 363-7026. Projects must be done by a Certified Lead Renovation Firm AND a Certified Renovator When disturbing lead-based painted or coated surfaces or components more than 6 ft2 per interior room or 20 ft2 of exterior surfaces AND all window replacements and partial demolitions of any size. * * * * * * * * * * * * * * ** * * * * * Asbestos/Environmental Notification to Georgia EPD for Projects Involving Demolition, Wrecking, or Renovation The undersigned hereby acknowledges that the issuance of this permit does not in any way grant permission to the owner, owner's representative, or permit holder to proceed with demolition, wrecking, or renovation of a structure prior to the filing of any required ten (10) day "Project Notification for Asbestos Renovation Encapsulation or Demolition" form in accordance with the Georgia Asbestos Rules. The Georgia Environmental Protection Division administers the rules. In most cases, the rules require both the owner and the involved contractors to assure the portion of the building involved in the project is thoroughly inspected by an Accredited Asbestos Inspector for materials that contain asbestos; and the removal of the asbestos before renovation, wrecking, or demolition begins almost without exemption. Georgia EPD requires a completed demolition notification from be submitted 10 workings days in advance even if no asbestos is present in the building. Further guidance for regulatory compliance and contact telephone numbers are provided by the brochures entitled Asbestos & Renovation and Asbestos and Demolition. Other environmental issues such as asbestos removal techniques, lead abatement, ground contamination, or unusual site conditions may have EPD regulations that could affect the project. * * * * ** * * ** * * * * * * * * * ** BMPs While BMP deficiencies are not necessarily the fault of the owner or his agent, BMPs are their responsibility. Two areas of deficiencies are in the most basic and common BMPs; Co — Construction Exit and Sd1 — Sediment Barrier. Correct installation information can be found in the Field Manual for Erosion and Sediment Control in Georgia, Fourth Edition 2002, Georgia Soil and Water Conservation Commission; http://www.gaswcc.org/docs/field_manual_4ed.pdf. Problems with the Co is not limited to the installation, but to material. The stone will be a representation of 1.5"-3.5" stone or larger. Type A sediment barriers have been installed where Type C is required and shown on the permit drawings. Where two rows are called for they will be installed with a separation that allows for the first one to fail (fall over) without impacting the second one. The complete assembly and installation must be compliant; steel or wood posts, post spacing, Type C or A. Yl4A\O)AC'tk 0311A)tig-011 Signature for receipt of Lead Paint, Asbestos, and BMP notices. Date \n/ - CQ04-0.1"e-t Printed Name